Skip to content
worldfires
CA · Canada · –

Bulkley-Nechako E fire, 2 August 2018 Bulkley-Nechako E, Bulkley-Nechako D

Out · last detection 5 Sept 2018, 10:04 UTC

The fire started on 2 August 2018 in Bulkley-Nechako E, Canada, and satellites saw it burning for 35 days. Canada’s CWFIS (Natural Resources Canada) mapped an official burnt perimeter of 52,517 hectares from satellite imagery, spread across 2 census subdivisions.

It is the 25th largest in British Columbia since 2016 (of 347 with a page). Number 9 in Canada in 2018, of 211.

Burnt area
52,517ha
official perimeter (CWFIS)
Duration
35days
2 Aug 2018 – 5 Sept 2018
Census subdivisions hit
2
municipalities
Started on
2 Aug
2018
Heat detections
12,713
in a single hotspot: 0 MW
Danger at start
12
Moderate · FWI index
Average daily power
6.6GW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 2 Aug5 Sept
5 Sept 2018

How it evolved, day by day

2 Aug 2018 · 9 MW · 4 3 Aug 2018 · 33 MW · 7 6 Aug 2018 · 8 MW · 2 7 Aug 2018 · 285 MW · 15 8 Aug 2018 · 2,966 MW · 77 9 Aug 2018 · 4,470 MW · 108 10 Aug 2018 · 2,440 MW · 103 11 Aug 2018 · 5,165 MW · 494 12 Aug 2018 · 3,048 MW · 272 13 Aug 2018 · 985 MW · 226 14 Aug 2018 · 1,733 MW · 217 15 Aug 2018 · 3,084 MW · 411 16 Aug 2018 · 6,465 MW · 334 17 Aug 2018 · 36,914 MW · 889 18 Aug 2018 · 19,160 MW · 1177 19 Aug 2018 · 19,058 MW · 954 20 Aug 2018 · 9,971 MW · 1072 21 Aug 2018 · 7,751 MW · 724 22 Aug 2018 · 58,711 MW · 1464 23 Aug 2018 · 6,974 MW · 1096 24 Aug 2018 · 5,034 MW · 699 25 Aug 2018 · 137 MW · 10 26 Aug 2018 · 860 MW · 81 27 Aug 2018 · 11,866 MW · 643 28 Aug 2018 · 1,560 MW · 377 29 Aug 2018 · 2,107 MW · 344 30 Aug 2018 · 889 MW · 45 31 Aug 2018 · 1,343 MW · 160 1 Sept 2018 · 4,660 MW · 563 2 Sept 2018 · 57 MW · 14 3 Sept 2018 · 105 MW · 41 4 Sept 2018 · 672 MW · 81 5 Sept 2018 · 19 MW · 9
2 Aug 11 Aug 22 Aug 1 Sept

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

26°high
71km/h · peak gust
18%lowest humidity

It had gone 0 days without rain (1 mm or more) when it started. Rain came after the fire: 4.6 mm on 7 Sept.

How big is it?

10 km
It burned the equivalent of 33% of the area of London (525 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each census subdivision

  1. Bulkley-Nechako E where it started
    48,195 ha
    2.7 %
  2. 4,469 ha
    1.0 %

Burnt area inside each census subdivision, from crossing the official perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
2 Aug 20.2 °C 39 % 49 km/h 0.0 mm Moderate 12
3 Aug 19.2 °C 46 % 44 km/h 0.4 mm Moderate 16
4 Aug 19.6 °C 41 % 19 km/h 0.0 mm Moderate 14
5 Aug 24.3 °C 30 % 21 km/h 0.0 mm Moderate 19
6 Aug 24.4 °C 23 % 47 km/h 0.0 mm Very high 39
7 Aug 25.5 °C 23 % 31 km/h 0.0 mm High 33
8 Aug 25.0 °C 31 % 39 km/h 0.0 mm Very high 38
9 Aug 24.3 °C 32 % 48 km/h 0.0 mm Very high 39
10 Aug 22.4 °C 32 % 36 km/h 0.0 mm High 31
11 Aug 18.2 °C 29 % 28 km/h 0.0 mm High 27
12 Aug 22.3 °C 26 % 27 km/h 0.0 mm High 25
13 Aug 24.1 °C 29 % 34 km/h 0.0 mm High 30
14 Aug 23.3 °C 31 % 44 km/h 0.0 mm High 34
15 Aug 18.7 °C 30 % 22 km/h 0.0 mm High 22
16 Aug 22.9 °C 18 % 33 km/h 0.0 mm High 31
17 Aug 20.8 °C 28 % 42 km/h 0.0 mm High 35
18 Aug 19.9 °C 31 % 24 km/h 0.0 mm High 26
19 Aug 21.3 °C 29 % 25 km/h 0.0 mm High 27
20 Aug 22.5 °C 25 % 16 km/h 0.0 mm High 26
21 Aug 26.1 °C 19 % 26 km/h 0.0 mm High 34
22 Aug 21.4 °C 34 % 45 km/h 0.0 mm Very high 38
23 Aug 15.8 °C 39 % 37 km/h 0.0 mm High 33
24 Aug 18.0 °C 34 % 33 km/h 0.0 mm High 29
25 Aug 15.0 °C 51 % 39 km/h 1.1 mm Moderate 17
26 Aug 16.0 °C 40 % 43 km/h 0.4 mm Moderate 21
27 Aug 20.2 °C 37 % 41 km/h 0.0 mm High 28
28 Aug 19.3 °C 40 % 49 km/h 0.0 mm High 31
29 Aug 15.1 °C 40 % 38 km/h 0.0 mm High 29
30 Aug 16.2 °C 36 % 44 km/h 0.0 mm High 33
31 Aug 13.1 °C 51 % 71 km/h 0.2 mm High 37
1 Sept 13.6 °C 40 % 40 km/h 0.0 mm High 28
2 Sept 12.2 °C 46 % 52 km/h 2.5 mm Low 10
3 Sept 13.1 °C 40 % 27 km/h 0.0 mm Low 11
4 Sept 16.5 °C 33 % 23 km/h 0.0 mm Moderate 15
5 Sept 16.1 °C 40 % 20 km/h 0.3 mm Moderate 17
6 Sept after 16.3 °C 41 % 22 km/h 0.1 mm Moderate 18
7 Sept after 16.2 °C 51 % 28 km/h 4.6 mm Low 8

Its twins: fires that started in the same weather

It started with an FWI of 12.0, a minimum humidity of 39% and rain the day before. Fires in the area that started in weather like this since 2017: 22.

FWI at the start 12.0
Minimum humidity 39 %
Days without rain 0
this fire chosen twins rest of the area
Almost identicalSimilar

Outlines of the closest twins

Bulkley-Nechako E fire, July 2024
58,800 ha 90 days FWI 11.9 Min. humidity 39 % 50 km away, in 2024

First rain (1 mm or more) after it ended: 14.3 mm on 13 Oct.

What happened to them

62 days
median duration
4,501 ha
median area
32 %
went past 10,000 ha
5.5 mm
rain at the end (median; 22 of 22 had it)

It was 11.7 times larger than the median of its twins and lasted 35 days, against 62 days.

Only 1 of its 22 twins burned more. The weather on the first day does not explain everything: the wind in the following days, the fuel and the firefighting also count. All of them had rain in the ten days after the end: the first rainy day brought a median of 5.5 mm.

This is a bank of analogues: it shows what usually happens, not what will happen. With fewer than 15 twins we give no figures. How we calculate it

How it ended

4.6 mmfirst rain
7 Sept2 days after it ended
71km/h · max. gust

It was considered over on 5 Sept, and on 7 Sept 4.6 mm fell. We do not know whether the rain or the firefighters put it out. Twins with rain when they ended: 22 of 22, with a median of 5.5 mm.

Weather on this page: Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

How a twin is chosen

  • Same area: fires that have already ended, less than 250 km from this one, since 2017.
  • Same start: we compare the FWI on the first day, the minimum humidity that day and the run of days without rain before it. The slider sets how much they may differ.
  • Only pages with final weather data (ERA5 reanalysis) calculated in the same way as this fire’s; agricultural and grass burns and pages with data under review are left out.
  • Fires burning at the same time as this one (a week before or after) are left out: they share the same spell of weather and do not count as a precedent.
  • They are sorted by similarity, and the outlines of the first five are drawn.

How we calculate it

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 26 Jul 2018
After · 12 Sept 2018

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

Detections table · 0Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Canada

Frequently asked questions

How long did the Bulkley-Nechako E fire last?
It burned between 2 August 2018 and 5 September 2018: 35 days, according to the dates recorded by Canada’s CWFIS and the heat detections seen by satellite.
How much area did it burn?
The official perimeter mapped by Canada’s CWFIS (Natural Resources Canada) is 52,517 hectares (525.2 km²). Other tallies, such as those of provincial agencies, may give slightly different figures.
Which census subdivisions burned?
The fire entered 2 census subdivisions: Bulkley-Nechako E (48,195 ha, 2.7 %); Bulkley-Nechako D (4,469 ha, 1.0 %).
What was the weather like?
During the fire the temperature reached 26.1 °C, humidity dropped to 18 % and gusts hit 71 km/h. The fire danger index (FWI) reached 39, class Very high.
Where does this data come from?
From the official burnt perimeter of Canada’s CWFIS (NBAC, Natural Resources Canada) or, for the current season and until NBAC publishes it, the one rebuilt by GWIS (Copernicus); from NASA FIRMS VIIRS hotspots; and from the administrative boundaries of Canada. It is not an official report.
How did the fires that started in similar weather in this area end?
Fires less than 250 km away that started since 2017 with a similar FWI, humidity and dry spell: 22. Their median duration was 62 days and their median area 4,501 ha; 32 % went past 10,000 ha. Only 1 of its 22 twins burned more. The weather on the first day does not explain everything: the wind in the following days, the fuel and the firefighting also count. All of them had rain in the ten days after the end: the first rainy day brought a median of 5.5 mm.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Emergency number: 911 · Emergency number and official warnings

Satellite cross-check

History of this page Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy. This is not an emergency service: if there is a fire now, call 911.

How we know this
  • Perimeter: NBAC (Natural Resources Canada), official.
  • Dates from the perimeter: the VIIRS detections inside it did not change them. No Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.

How we build fire pages: methodology

Where this data comes from

The perimeter is official: it comes from the National Burned Area Composite (NBAC) of the Canadian Wildland Fire Information System (CWFIS), Natural Resources Canada, which maps it on satellite imagery and publishes it under the Open Government Licence – Canada. Until NBAC publishes the current season, this year’s fires carry the perimeter rebuilt from heat detections by GWIS (Copernicus, CC BY 4.0), which is approximate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Census subdivision boundaries come from geoBoundaries ADM3 (Open Data Commons Open Database License 1.0). The area per census subdivision is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ slightly from official figures.