Skip to content
worldfires
SS · South Sudan · →

Ulang fire, March 2025 Ulang, Nyirol

Out · last detection 17 Mar 2025, 10:54 UTC

The fire started on 3 March 2025 in Ulang, South Sudan, and satellites saw it burning for 14 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 5,668 hectares from heat detections, spread across 2 municipalities.

It is the 216th largest in Upper Nile since 2016 (of 284 with a page). Number 236 in South Sudan in 2025, of 292.

Compare with…
Burnt area
5,668ha
GWIS perimeter (Copernicus)
Duration
14days
3 Mar 2025 – 16 Mar 2025
Municipalities hit
2
counties
Started on
3 Mar
2025
Heat detections
242
in a single hotspot: 136 MW
Danger at start
56
Extreme · FWI index
Average daily power
281MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 3 Mar16 Mar
17 Mar 2025

How it evolved, day by day

3 Mar 2025 · 104 MW · 13 5 Mar 2025 · 48 MW · 6 6 Mar 2025 · 623 MW · 23 7 Mar 2025 · 139 MW · 9 8 Mar 2025 · 151 MW · 17 10 Mar 2025 · 111 MW · 15 11 Mar 2025 · 301 MW · 18 12 Mar 2025 · 516 MW · 31 13 Mar 2025 · 113 MW · 9 14 Mar 2025 · 807 MW · 37 15 Mar 2025 · 554 MW · 24 16 Mar 2025 · 109 MW · 4 17 Mar 2025 · 77 MW · 3
3 Mar 6 Mar 8 Mar 11 Mar 13 Mar 14 Mar 15 Mar 17 Mar

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

42°high
50km/h · peak gust
7%lowest humidity

It had gone more than two months without rain (1 mm or more) when it started. Rain came after the fire: 2.8 mm on 21 Mar.

This area had burned before

100% of the perimeter overlaps earlier fires recorded since 2016: 2,201 ha in 2016, 2,438 ha in 2017, 1,887 ha in 2018, 4,859 ha in 2019, 766 ha in 2020, 3,253 ha in 2021, 5,811 ha in 2022, 3,765 ha in 2023, 4,606 ha in 2024. Part of it burned more than once, so the yearly figures add up to more than the 5,705 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 3.6% of the area of London (57 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Ulang where it started
    3,604 ha reached on 27 Feb
    0.7 %
  2. 2,102 ha reached on 5 Mar
    0.3 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area< 0.1 ha
Residents< 20

Inside the perimeter there was no noticeable built-up land and almost nobody lived there (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
3 Mar 40.0 °C 13 % 34 km/h 0.0 mm Extreme 56
4 Mar 38.6 °C 9 % 32 km/h 0.0 mm Extreme 59
5 Mar 40.8 °C 10 % 35 km/h 0.0 mm Extreme 62
6 Mar 41.3 °C 8 % 33 km/h 0.0 mm Extreme 62
7 Mar 39.6 °C 8 % 50 km/h 0.0 mm Very extreme 77
8 Mar 38.8 °C 8 % 45 km/h 0.0 mm Very extreme 74
9 Mar 38.7 °C 7 % 45 km/h 0.0 mm Very extreme 74
10 Mar 38.9 °C 8 % 38 km/h 0.0 mm Extreme 68
11 Mar 39.1 °C 10 % 37 km/h 0.0 mm Extreme 66
12 Mar 40.3 °C 9 % 41 km/h 0.0 mm Very extreme 71
13 Mar 40.0 °C 13 % 22 km/h 0.0 mm Extreme 53
14 Mar 40.9 °C 10 % 22 km/h 0.0 mm Extreme 53
15 Mar 41.8 °C 7 % 42 km/h 0.0 mm Extreme 69
16 Mar 42.3 °C 7 % 31 km/h 0.0 mm Extreme 59
17 Mar after 41.1 °C 10 % 35 km/h 0.0 mm Extreme 64
18 Mar after 39.3 °C 22 % 36 km/h 0.0 mm Extreme 54
19 Mar after 37.7 °C 24 % 33 km/h 0.1 mm Extreme 51
20 Mar after 38.8 °C 21 % 36 km/h 0.0 mm Extreme 52
21 Mar after 38.4 °C 25 % 36 km/h 2.8 mm High 33

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 24 Feb 2025
After · 23 Mar 2025

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 4 March 2025 the air beside the fire reached 102 µg/m³ of PM2.5. That day averaged 73: 4.9 times the WHO daily guideline (15).

PM2.5 peak102 µg/m³
Days over the guideline19 days
PM10113 µg/m³
Optical depth1.49
12345678910111213141516171819
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 242Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in South Sudan ›

Frequently asked questions

How long did the Ulang fire last?
GWIS (Copernicus) dates it between 3 March 2025 and 16 March 2025: 14 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 5,668 hectares (56.7 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire entered 2 municipalities: Ulang (3,604 ha, 0.7 %); Nyirol (2,102 ha, 0.3 %).
What was the weather like?
During the fire the temperature reached 42.3 °C, humidity dropped to 7 % and gusts hit 50 km/h. The fire danger index (FWI) reached 77, class Very extreme.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of South Sudan (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

History of this page Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.

No changes since 24 October 2026.

RSS Changes to this page

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates from the perimeter: the VIIRS detections inside it did not change them. 242 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology ›

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.