Skip to content
worldfires
KH · Cambodia · –

Trapeang Prasat fire, February 2020 Trapeang Prasat

Out · last measured on

The fire started on in Trapeang Prasat, Cambodia, and satellites saw it burning for 16 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 2,057 hectares from heat detections, spread across a single municipality.

It is number 11 by size of the 12 fires with a page that started in Oddar Meanchey since 2016. Number 76 in Cambodia in 2020, of 77.

We have the GWIS perimeter for this fire, but the VIIRS sensors did not capture it in enough detail: no day-by-day evolution, but the split by municipality is there.

Burnt area
2,057ha
GWIS perimeter (Copernicus)
Duration
16days
12 Feb 2020 – 27 Feb 2020
Municipalities hit
1
districts
Started on
12 Feb
2020
Danger at start
26
High · FWI index

Where it burned

The weather it burned in

37°high
41km/h · peak gust
33%lowest humidity

It had gone more than two months without rain (1 mm or more) when it started. Rain came after the fire: 2.0 mm on 5 Mar.

This area had burned before

No earlier perimeters overlap this fire since 2016, when the satellite record begins.

How big is it?

10 km
It burned the equivalent of 1.3% of the area of London (21 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Trapeang Prasat where it started
    2,070 ha
    1.4 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2020
Built-up area0.52 ha
Residents≈ 2,200

Inside the perimeter there were about 0.52 hectares of built-up land and about 2,200 residents (GHSL 2020, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Started with 60 days without rain: 11 % of the area in Cambodia

Day High Min. humidity Peak gust Rain Danger (FWI)
12 Feb 34.5 °C 48 % 26 km/h 0.0 mm High 26
13 Feb 34.1 °C 48 % 24 km/h 0.0 mm High 28
14 Feb 34.3 °C 56 % 31 km/h 0.1 mm High 29
15 Feb 35.6 °C 42 % 27 km/h 0.0 mm High 28
16 Feb 37.0 °C 36 % 28 km/h 0.0 mm High 24
17 Feb 32.9 °C 50 % 41 km/h 0.0 mm High 29
18 Feb 30.9 °C 47 % 41 km/h 0.0 mm High 30
19 Feb 32.3 °C 45 % 27 km/h 0.0 mm High 29
20 Feb 32.5 °C 41 % 30 km/h 0.0 mm High 30
21 Feb 32.7 °C 39 % 35 km/h 0.0 mm High 34
22 Feb 33.2 °C 39 % 37 km/h 0.0 mm High 32
23 Feb 32.6 °C 42 % 36 km/h 0.0 mm High 29
24 Feb 33.0 °C 39 % 26 km/h 0.0 mm High 29
25 Feb 34.4 °C 33 % 23 km/h 0.0 mm High 30
26 Feb 34.6 °C 37 % 28 km/h 0.0 mm High 32
27 Feb 33.4 °C 45 % 32 km/h 0.0 mm High 34
28 Feb after 34.2 °C 39 % 31 km/h 0.0 mm High 34
29 Feb after 35.3 °C 38 % 30 km/h 0.0 mm High 34
1 Mar after 35.5 °C 39 % 23 km/h 0.0 mm High 32
2 Mar after 35.3 °C 45 % 21 km/h 0.0 mm High 30
3 Mar after 35.2 °C 46 % 20 km/h 0.1 mm High 28
4 Mar after 34.9 °C 50 % 17 km/h 0.2 mm High 25
5 Mar after 33.1 °C 61 % 18 km/h 2.0 mm Low 7

Its twins: fires that started in the same weather

It started with an FWI of 26.4, a minimum humidity of 48% and more than two months without rain. Fires in the area that started in weather like this since 2016: 32.

FWI at the start 26.4
Minimum humidity 48 %
Days without rain 60+
this fire chosen twins rest of the area
Almost identicalSimilar

Outlines of the closest twins

Nam Yuen fire, March 2019
1,462 ha 9 days FWI 26.6 Min. humidity 49 % 83 km away, in 2019

First rain (1 mm or more) after it ended: 4.7 mm on 23 Mar.

What happened to them

21 days
median duration
2,539 ha
median area
100 %
went past 1,000 ha
2.1 mm
rain at the end (median; 8 of 32 had it)

It burned an area similar to its twins (2,057 ha against a median of 2,539 ha) and lasted 16 days, against 21 days.

In 24 of 32, not even 1 mm fell in the ten days after the end: they went out without rain. In the rest, the first rainy day brought a median of 2.1 mm.

This is a bank of analogues: it shows what usually happens, not what will happen. With fewer than 15 twins we give no figures. How we calculate it

How it ended

2.0 mmfirst rain
5 Mar7 days after it ended
41km/h · max. gust

It was considered over on 27 Feb, and on 5 Mar 2.0 mm fell. We do not know whether the rain or the firefighters put it out. Twins with rain when they ended: 8 of 32, with a median of 2.1 mm.

Weather on this page: Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

How a twin is chosen

  • Same area: fires that have already ended, less than 250 km from this one, since 2016.
  • Same start: we compare the FWI on the first day, the minimum humidity that day and the run of days without rain before it. The slider sets how much they may differ.
  • Only pages with final weather data (ERA5 reanalysis) calculated in the same way as this fire’s; agricultural and grass burns and pages with data under review are left out.
  • Fires burning at the same time as this one (a week before or after) are left out: they share the same spell of weather and do not count as a precedent.
  • They are sorted by similarity, and the outlines of the first five are drawn.

How we calculate it

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 5 Feb 2020
After · 5 Mar 2020

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

Other fires nearby

All fires in Cambodia

Frequently asked questions

How long did the Trapeang Prasat fire last?
GWIS (Copernicus) dates it between 12 February 2020 and 27 February 2020: 16 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 2,057 hectares (20.6 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Trapeang Prasat (2,070 ha, 1.4 %).
What was the weather like?
During the fire the temperature reached 37.0 °C, humidity dropped to 33 % and gusts hit 41 km/h. The fire danger index (FWI) reached 34, class High.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Cambodia (geoBoundaries). It is not an official report.
How did the fires that started in similar weather in this area end?
Fires less than 250 km away that started since 2016 with a similar FWI, humidity and dry spell: 32. Their median duration was 21 days and their median area 2,539 ha; 100 % went past 1,000 ha. In 24 of 32, not even 1 mm fell in the ten days after the end: they went out without rain. In the rest, the first rainy day brought a median of 2.1 mm.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

History of this page Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates from the perimeter: the VIIRS detections inside it did not change them. No Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2020, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 4.0 International (CC BY 4.0)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.