Skip to content
worldfires
BO · Bolivia · –

San Ramón fire, 25 July 2019 San Ramón, San Joaquín

Out · last detection 26 Aug 2019, 16:56 UTC

The fire started on 25 July 2019 in San Ramón, Bolivia, and satellites saw it burning for 32 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 101,140 hectares from heat detections, spread across 2 municipalities.

This page is probably a fire complex, not a single fire. GWIS merges into one perimeter the fires that touch over weeks, which in large burning seasons can join dozens of separate fires. The total area is reliable; the origin and dates refer to the whole complex.

Other fire pages in the same area and on the same dates:

It is the 3th largest in Beni since 2016 (of 858 with a page). Number 8 in Bolivia in 2019, of 218.

Burnt area
101,140ha
GWIS perimeter (Copernicus)
Duration
32days
25 Jul 2019 – 25 Aug 2019
Municipalities hit
2
municipalities
Started on
25 Jul
2019
Heat detections
4,140
in a single hotspot: 696 MW
Danger at start
7
Low · FWI index
Average daily power
2.4GW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 25 Jul25 Aug
26 Aug 2019

How it evolved, day by day

25 Jul 2019 · 38 MW · 3 26 Jul 2019 · 212 MW · 18 27 Jul 2019 · 403 MW · 27 28 Jul 2019 · 56 MW · 2 31 Jul 2019 · 254 MW · 18 1 Aug 2019 · 462 MW · 21 2 Aug 2019 · 343 MW · 24 3 Aug 2019 · 242 MW · 41 4 Aug 2019 · 2,691 MW · 88 5 Aug 2019 · 3,751 MW · 140 6 Aug 2019 · 4,656 MW · 143 7 Aug 2019 · 7,330 MW · 321 8 Aug 2019 · 4,906 MW · 313 9 Aug 2019 · 2,358 MW · 185 10 Aug 2019 · 2,556 MW · 154 11 Aug 2019 · 2,167 MW · 160 12 Aug 2019 · 651 MW · 73 13 Aug 2019 · 2,276 MW · 153 14 Aug 2019 · 6,216 MW · 439 15 Aug 2019 · 3,839 MW · 400 16 Aug 2019 · 11,562 MW · 260 17 Aug 2019 · 8,622 MW · 415 18 Aug 2019 · 4,171 MW · 341 19 Aug 2019 · 983 MW · 76 20 Aug 2019 · 977 MW · 35 21 Aug 2019 · 407 MW · 37 22 Aug 2019 · 673 MW · 89 23 Aug 2019 · 683 MW · 69 24 Aug 2019 · 898 MW · 63 25 Aug 2019 · 368 MW · 30 26 Aug 2019 · 13 MW · 2
25 Jul 3 Aug 10 Aug 16 Aug 24 Aug

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

35°high
51km/h · peak gust
19%lowest humidity

It had gone 5 days without rain (1 mm or more) when it started. Rain came after the fire: 7.6 mm on 26 Aug.

This area had burned before

45% of the perimeter overlaps earlier fires recorded since 2016: 5,589 ha in 2016, 6,342 ha in 2017, 10,067 ha in 2018.

How big is it?

10 km
It burned the equivalent of 64% of the area of London (1,011 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. San Ramón 5,489 inhabitants where it started
    84,484 ha
    10 %
  2. San Joaquín 6,808 inhabitants
    17,403 ha
    2.0 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2020
Built-up area1.4 ha
Residents≈ 90

Inside the perimeter there were about 1.4 hectares of built-up land and about 90 residents (GHSL 2020, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
25 Jul 18.2 °C 61 % 34 km/h 0.6 mm Low 7
26 Jul 24.6 °C 49 % 31 km/h 0.0 mm Moderate 14
27 Jul 27.8 °C 44 % 38 km/h 0.0 mm High 22
28 Jul 31.2 °C 42 % 25 km/h 0.0 mm Moderate 17
29 Jul 32.1 °C 42 % 20 km/h 0.0 mm Moderate 16
30 Jul 33.1 °C 40 % 14 km/h 0.0 mm Moderate 15
31 Jul 33.8 °C 39 % 19 km/h 0.0 mm Moderate 16
1 Aug 33.8 °C 39 % 32 km/h 0.0 mm High 23
2 Aug 30.8 °C 23 % 50 km/h 0.0 mm High 33
3 Aug 23.7 °C 19 % 51 km/h 0.0 mm Very high 42
4 Aug 25.4 °C 20 % 44 km/h 0.0 mm Very high 44
5 Aug 27.8 °C 24 % 33 km/h 0.0 mm High 36
6 Aug 30.6 °C 30 % 16 km/h 0.0 mm High 24
7 Aug 33.1 °C 34 % 30 km/h 0.0 mm High 35
8 Aug 33.4 °C 40 % 25 km/h 0.0 mm High 26
9 Aug 34.2 °C 45 % 24 km/h 0.0 mm High 26
10 Aug 30.9 °C 46 % 24 km/h 0.0 mm High 27
11 Aug 33.1 °C 41 % 24 km/h 0.0 mm High 23
12 Aug 34.1 °C 41 % 19 km/h 0.0 mm High 23
13 Aug 31.8 °C 30 % 48 km/h 0.0 mm Very high 44
14 Aug 27.3 °C 28 % 49 km/h 0.0 mm Very high 47
15 Aug 30.8 °C 30 % 28 km/h 0.0 mm High 34
16 Aug 33.7 °C 34 % 17 km/h 0.0 mm High 27
17 Aug 34.4 °C 38 % 40 km/h 0.0 mm Very high 43
18 Aug 34.6 °C 43 % 38 km/h 0.0 mm High 35
19 Aug 30.8 °C 57 % 23 km/h 10.5 mm Moderate 15
20 Aug 31.0 °C 46 % 27 km/h 0.0 mm Very low 5
21 Aug 30.4 °C 42 % 33 km/h 0.0 mm Moderate 19
22 Aug 34.9 °C 41 % 23 km/h 0.0 mm Moderate 20
23 Aug 32.5 °C 42 % 41 km/h 0.0 mm High 29
24 Aug 34.8 °C 45 % 24 km/h 0.0 mm High 22
25 Aug 35.1 °C 48 % 31 km/h 2.6 mm High 22
26 Aug after 31.5 °C 62 % 30 km/h 7.6 mm Very low 4

Its twins: fires that started in the same weather

It started with an FWI of 7.1, a minimum humidity of 61% and 5 days without rain. Fires in the area that started in weather like this since 2016: 15.

FWI at the start 7.1
Minimum humidity 61 %
Days without rain 5
this fire chosen twins rest of the area
Almost identicalSimilar

Outlines of the closest twins

Huacaraje fire, October 2023
19,681 ha 19 days FWI 9.0 Min. humidity 61 % 68 km away, in 2023

First rain (1 mm or more) after it ended: 2.5 mm on 27 Oct.

What happened to them

12 days
median duration
5,225 ha
median area
20 %
went past 10,000 ha
4.1 mm
rain at the end (median; 13 of 15 had it)

It was 19.4 times larger than the median of its twins and lasted 32 days, against 12 days.

None of its 15 twins burned more. The weather on the first day does not explain everything: the wind in the following days, the fuel and the firefighting also count. In 2 of 15, not even 1 mm fell in the ten days after the end: they went out without rain. In the rest, the first rainy day brought a median of 4.1 mm.

This is a bank of analogues: it shows what usually happens, not what will happen. With fewer than 15 twins we give no figures. How we calculate it

How it ended

7.6 mmfirst rain
26 Augthe day after it ended
51km/h · max. gust

It was considered over on 25 Aug, and on 26 Aug 7.6 mm fell. We do not know whether the rain or the firefighters put it out. Twins with rain when they ended: 13 of 15, with a median of 4.1 mm.

Weather on this page: Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

How a twin is chosen

  • Same area: fires that have already ended, less than 250 km from this one, since 2016.
  • Same start: we compare the FWI on the first day, the minimum humidity that day and the run of days without rain before it. The slider sets how much they may differ.
  • Only pages with final weather data (ERA5 reanalysis) calculated in the same way as this fire’s; agricultural and grass burns and pages with data under review are left out.
  • Fires burning at the same time as this one (a week before or after) are left out: they share the same spell of weather and do not count as a precedent.
  • They are sorted by similarity, and the outlines of the first five are drawn.

How we calculate it

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 18 Jul 2019
After · 1 Sept 2019

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

Detections table · 4,140Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Bolivia

Frequently asked questions

How long did the San Ramón fire last?
According to the heat detections seen by satellite inside the perimeter, it burned from 25 July 2019 to 25 August 2019 (32 days). The perimeter dates it from 31 July 2019 to 25 August 2019.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 101,140 hectares (1,011.4 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire entered 2 municipalities: San Ramón (84,484 ha, 10 %); San Joaquín (17,403 ha, 2.0 %).
What was the weather like?
During the fire the temperature reached 35.1 °C, humidity dropped to 19 % and gusts hit 51 km/h. The fire danger index (FWI) reached 47, class Very high.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Bolivia (geoBoundaries). It is not an official report.
How did the fires that started in similar weather in this area end?
Fires less than 250 km away that started since 2016 with a similar FWI, humidity and dry spell: 15. Their median duration was 12 days and their median area 5,225 ha; 20 % went past 10,000 ha. None of its 15 twins burned more. The weather on the first day does not explain everything: the wind in the following days, the fuel and the firefighting also count. In 2 of 15, not even 1 mm fell in the ten days after the end: they went out without rain. In the rest, the first rainy day brought a median of 4.1 mm.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Emergency number: 119 · 110 · Emergency number and official warnings

Satellite cross-check

History of this page Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy. This is not an emergency service: if there is a fire now, call 119 · 110.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates adjusted with the VIIRS detections inside the perimeter, which said 31 July 2019 to 25 August 2019. 4,140 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2020, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM3 (Public Domain). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.