Skip to content
worldfires
BR · Brazil · →

Pracuúba fire, 23 November 2016 Pracuúba

Out · last detection 13 Dec 2016, 16:47 UTC

The fire started on 23 November 2016 in Pracuúba, Brazil, and satellites saw it burning for 20 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 7,621 hectares from heat detections, spread across a single municipality.

It is the 8th largest in Amapá since 2016 (of 41 with a page). Number 153 in Brazil in 2016, of 649.

Burnt area
7,621ha
GWIS perimeter (Copernicus)
Duration
20days
23 Nov 2016 – 12 Dec 2016
Municipalities hit
1
municipalities
Started on
23 Nov
2016
Heat detections
773
in a single hotspot: 85 MW
Danger at start
18
Moderate · FWI index
Average daily power
253MW
detected power per day, on average

Where it burned

13 Dec 2016
HOTSPOTS BY DAY 23 Nov12 Dec

How it evolved, day by day

23 Nov 2016 · 54 MW · 10 24 Nov 2016 · 39 MW · 16 25 Nov 2016 · 26 MW · 19 26 Nov 2016 · 75 MW · 25 27 Nov 2016 · 31 MW · 4 28 Nov 2016 · 21 MW · 5 29 Nov 2016 · 101 MW · 36 30 Nov 2016 · 142 MW · 40 1 Dec 2016 · 182 MW · 38 2 Dec 2016 · 353 MW · 55 3 Dec 2016 · 1,225 MW · 113 4 Dec 2016 · 811 MW · 90 5 Dec 2016 · 649 MW · 84 6 Dec 2016 · 138 MW · 52 7 Dec 2016 · 633 MW · 60 8 Dec 2016 · 739 MW · 72 9 Dec 2016 · 29 MW · 12 10 Dec 2016 · 7 MW · 4 11 Dec 2016 · 47 MW · 15 12 Dec 2016 · 6 MW · 2 13 Dec 2016 · 5 MW · 2
23 Nov 26 Nov 29 Nov 2 Dec 3 Dec 5 Dec 8 Dec 11 Dec

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

35°high
47km/h · peak gust
44%lowest humidity

It had gone 2 days without rain (1 mm or more) when it started. Rain came after the fire: 12.9 mm on 14 Dec.

This area had burned before

No earlier perimeters overlap this fire since 2016, when the satellite record begins.

What happened to each town

  1. Pracuúba 7,943 inhabitants where it started
    7,673 ha reached on 16 Nov
    1.5 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance is from the town centre to the nearest fire: staying a kilometre away does not mean it reached the houses.

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
16 Nov 34.4 °C 56 % 38 km/h 0.0 mm Moderate 18
17 Nov 34.3 °C 50 % 34 km/h 0.0 mm Moderate 20
18 Nov 34.8 °C 47 % 34 km/h 0.0 mm Moderate 21
19 Nov 33.8 °C 49 % 39 km/h 0.3 mm High 23
20 Nov 34.4 °C 48 % 33 km/h 0.1 mm Moderate 21
21 Nov 33.3 °C 52 % 39 km/h 0.0 mm High 24
22 Nov 34.2 °C 52 % 47 km/h 0.0 mm High 25
23 Nov 34.4 °C 46 % 37 km/h 0.0 mm High 24
24 Nov 34.2 °C 47 % 37 km/h 0.4 mm High 24
25 Nov 34.6 °C 48 % 40 km/h 0.0 mm High 25
26 Nov 33.9 °C 48 % 44 km/h 0.0 mm High 25
27 Nov 33.1 °C 54 % 37 km/h 0.0 mm High 24
28 Nov 33.9 °C 44 % 36 km/h 0.0 mm High 25
29 Nov 33.8 °C 50 % 35 km/h 0.0 mm High 25
30 Nov 33.7 °C 51 % 37 km/h 0.6 mm High 22
1 Dec 33.4 °C 56 % 38 km/h 0.9 mm Moderate 16
2 Dec 33.5 °C 49 % 40 km/h 0.2 mm High 22
3 Dec 33.0 °C 53 % 38 km/h 0.5 mm High 23
4 Dec 33.8 °C 56 % 40 km/h 0.0 mm High 22
5 Dec 34.2 °C 44 % 39 km/h 0.2 mm High 25
6 Dec 34.4 °C 58 % 34 km/h 0.0 mm High 22
7 Dec 34.1 °C 58 % 42 km/h 0.6 mm Moderate 20
8 Dec 34.4 °C 53 % 41 km/h 2.1 mm Moderate 13
9 Dec 32.3 °C 64 % 42 km/h 21.9 mm Very low 2
10 Dec 31.8 °C 70 % 34 km/h 21.1 mm Very low 0
11 Dec 31.7 °C 74 % 36 km/h 4.4 mm Very low 0
12 Dec 31.3 °C 72 % 37 km/h 10.8 mm Very low 0
13 Dec after 31.3 °C 71 % 34 km/h 14.6 mm Very low 0
14 Dec after 31.1 °C 67 % 31 km/h 12.9 mm Very low 0

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 16 Nov 2016
After · 19 Dec 2016

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

Detections table · 773Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Brazil ›

Frequently asked questions

How long did the Pracuúba fire last?
GWIS (Copernicus) dates it between 23 November 2016 and 12 December 2016: 20 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 7,621 hectares (76.2 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Pracuúba (7,673 ha, 1.5 %).
What was the weather like?
During the fire the temperature reached 34.8 °C, humidity dropped to 44 % and gusts hit 47 km/h. The fire danger index (FWI) reached 25, class High.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Brazil (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Emergency number: 193

Satellite cross-check

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy. This is not an emergency service: if there is a fire now, call 193.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery; 2 polygons grouped in this page.
  • Dates from the perimeter: the VIIRS detections inside it did not change them. 773 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.

How we build fire pages: methodology ›

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.