Skip to content
worldfires
KE · Kenya · –

Isiolo South fire, December 2020 Isiolo South, Lagdera

Out · last detection

The fire started on in Isiolo South, Kenya, and satellites saw it burning for 2 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 1,703 hectares from heat detections, spread across 2 municipalities.

It is number 14 by size of the 26 fires with a page that started in Isiolo since 2016. Number 25 in Kenya in 2020, of 62.

Burnt area
1,703ha
GWIS perimeter (Copernicus)
Duration
2days
24 Dec 2020 – 25 Dec 2020
Municipalities hit
2
constituencies
Started on
24 Dec
2020
Heat detections
66
in a single hotspot: 31 MW
Danger at start
25
High · FWI index
Average daily power
192MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 24 Dec25 Dec
25 Dec 2020

How it evolved, day by day

24 Dec 2020 · 370 MW · 59 25 Dec 2020 · 14 MW · 7
24 Dec 25 Dec

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

35°high
31km/h · peak gust
35%lowest humidity

It had gone 25 days without rain (1 mm or more) when it started. Rain came after the fire: 5.9 mm on 30 Dec.

This area had burned before

No earlier perimeters overlap this fire since 2016, when the satellite record begins.

How big is it?

10 km
It burned the equivalent of 1.1% of the area of London (17 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Isiolo South where it started
    1,667 ha reached on 24 Dec
    0.2 %
  2. 47 ha
    0.0 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2020
Built-up area< 0.1 ha
Residents< 20

Inside the perimeter there was no noticeable built-up land and almost nobody lived there (GHSL 2020, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
24 Dec 34.8 °C 37 % 28 km/h 0.0 mm High 25
25 Dec 35.4 °C 35 % 31 km/h 0.0 mm High 29
26 Dec after 34.9 °C 36 % 32 km/h 0.0 mm High 30
27 Dec after 34.7 °C 31 % 29 km/h 0.0 mm High 29
28 Dec after 35.2 °C 34 % 29 km/h 0.0 mm High 29
29 Dec after 35.2 °C 35 % 32 km/h 0.0 mm High 28
30 Dec after 32.8 °C 44 % 33 km/h 5.9 mm High 30

Its twins: fires that started in the same weather

It started with an FWI of 25.3, a minimum humidity of 37% and 25 days without rain. Fires in the area that started in weather like this since 2016: 8.

FWI at the start 25.3
Minimum humidity 37 %
Days without rain 25
this fire chosen twins rest of the area
Almost identicalSimilar

Outlines of the closest twins

Wajir West fire, April 2020
1,083 ha 3 days FWI 21.2 Min. humidity 39 % 110 km away, in 2020

First rain (1 mm or more) after it ended: 1.2 mm on 13 Apr.

What happened to them

Fires in the area that started in similar weather: 8. With fewer than 15 we give no figures: they would be more noise than signal.

This is a bank of analogues: it shows what usually happens, not what will happen. With fewer than 15 twins we give no figures. How we calculate it

How it ended

5.9 mmfirst rain
30 Dec5 days after it ended
31km/h · max. gust

It was considered over on 25 Dec, and on 30 Dec 5.9 mm fell. We do not know whether the rain or the firefighters put it out.

Weather on this page: Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

How a twin is chosen

  • Same area: fires that have already ended, less than 250 km from this one, since 2016.
  • Same start: we compare the FWI on the first day, the minimum humidity that day and the run of days without rain before it. The slider sets how much they may differ.
  • Only pages with final weather data (ERA5 reanalysis) calculated in the same way as this fire’s; agricultural and grass burns and pages with data under review are left out.
  • Fires burning at the same time as this one (a week before or after) are left out: they share the same spell of weather and do not count as a precedent.
  • They are sorted by similarity, and the outlines of the first five are drawn.

How we calculate it

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 17 Dec 2020
After · 1 Jan 2021

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

Detections table · 66Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Kenya

Frequently asked questions

How long did the Isiolo South fire last?
GWIS (Copernicus) dates it between 24 December 2020 and 25 December 2020: 2 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 1,703 hectares (17.0 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire entered 2 municipalities: Isiolo South (1,667 ha, 0.2 %); Lagdera (47 ha, 0.0 %).
What was the weather like?
During the fire the temperature reached 35.4 °C, humidity dropped to 35 % and gusts hit 31 km/h. The fire danger index (FWI) reached 29, class High.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Kenya (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Emergency number: 999 · 112 · Emergency number and official warnings

Satellite cross-check

History of this page Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy. This is not an emergency service: if there is a fire now, call 999 · 112.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates from the perimeter: the VIIRS detections inside it did not change them. 66 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2020, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.