Skip to content
worldfires
CD · Congo - Kinshasa · →

Feshi fire, 2 June 2026 Feshi

Out · last detection 12 Jun 2026, 13:06 UTC

The fire started on 2 June 2026 in Feshi, Congo - Kinshasa, and satellites saw it burning for 11 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 19,282 hectares from heat detections, spread across a single municipality.

It is the 15th largest in Kwango since 2016 (of 219 with a page). Number 71 in Congo - Kinshasa in 2026, of 523.

Burnt area
19,282ha
GWIS perimeter (Copernicus)
Duration
11days
2 Jun 2026 – 12 Jun 2026
Municipalities hit
1
territories
Started on
2 Jun
2026
Heat detections
519
in a single hotspot: 199 MW
Danger at start
24
High · FWI index
Energy released
18.2GW
sum of detected power

Where it burned

12 Jun 2026
HOTSPOTS BY DAY 2 Jun12 Jun

How it evolved, day by day

345689101112

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

33°high
40km/h · peak gust
20%lowest humidity

It had gone 12 days without rain (1 mm or more) when it started.

This area had burned before

97% of the perimeter overlaps earlier fires recorded since 2016: 6,124 ha in 2016, 12,257 ha in 2017, 6,189 ha in 2018, 10,546 ha in 2019, 4,699 ha in 2020, 6,552 ha in 2021, 5,382 ha in 2022, 4,258 ha in 2023, 207 ha in 2024, 2,680 ha in 2025. Part of it burned more than once, so the yearly figures add up to more than the 18,683 ha that had burned before.

What happened to each town

  1. Feshi where it started
    19,423 ha reached on 27 May
    1.0 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance is from the town centre to the nearest fire: staying a kilometre away does not mean it reached the houses.

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
2 Jun 31.9 °C 29 % 31 km/h 0.0 mm High 24
3 Jun 32.2 °C 28 % 28 km/h 0.0 mm High 24
4 Jun 31.8 °C 26 % 15 km/h 0.0 mm High 24
5 Jun 31.7 °C 27 % 17 km/h 0.0 mm High 26
6 Jun 31.9 °C 25 % 24 km/h 0.0 mm High 26
7 Jun 32.6 °C 29 % 30 km/h 0.0 mm High 28
8 Jun 31.3 °C 32 % 36 km/h 0.0 mm High 30
9 Jun 32.9 °C 27 % 40 km/h 0.0 mm High 34
10 Jun 32.2 °C 27 % 36 km/h 0.0 mm High 32
11 Jun 32.5 °C 29 % 27 km/h 0.0 mm High 31
12 Jun 32.2 °C 23 % 26 km/h 0.0 mm High 30
13 Jun after 31.7 °C 20 % 31 km/h 0.0 mm High 34
14 Jun after 31.9 °C 23 % 28 km/h 0.0 mm High 33
15 Jun after 30.8 °C 29 % 24 km/h 0.0 mm High 31
16 Jun after 29.9 °C 36 % 20 km/h 0.0 mm High 28
17 Jun after 30.5 °C 36 % 27 km/h 0.0 mm High 30
18 Jun after 28.5 °C 45 % 27 km/h 0.1 mm High 26
19 Jun after 30.1 °C 42 % 27 km/h 0.0 mm High 24
20 Jun after 32.3 °C 36 % 32 km/h 0.2 mm High 27
21 Jun after 31.6 °C 39 % 29 km/h 0.2 mm High 26
22 Jun after 29.8 °C 38 % 24 km/h 0.1 mm High 27
23 Jun after 29.5 °C 41 % 24 km/h 0.2 mm High 27
24 Jun after 31.5 °C 29 % 30 km/h 0.0 mm High 30
25 Jun after 32.2 °C 22 % 30 km/h 0.0 mm High 35
26 Jun after 30.5 °C 24 % 20 km/h 0.0 mm High 33
27 Jun after 32.3 °C 25 % 30 km/h 0.0 mm High 35

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 26 May 2026
After · 19 Jun 2026

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 7 June 2026 the air beside the fire reached 142 µg/m³ of PM2.5. That day averaged 89: 5.9 times the WHO daily guideline (15).

PM2.5 peak142 µg/m³
Days over the guideline15 days
PM10147 µg/m³
Optical depth0.97
31123456789101112131415
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 519Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Congo - Kinshasa ›

Frequently asked questions

How long did the Feshi fire last?
GWIS (Copernicus) dates it between 2 June 2026 and 12 June 2026: 11 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 19,282 hectares (192.8 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Feshi (19,423 ha, 1.0 %).
What was the weather like?
During the fire the temperature reached 32.9 °C, humidity dropped to 20 % and gusts hit 40 km/h. The fire danger index (FWI) reached 34, class High.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Congo - Kinshasa (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.