Skip to content
worldfires
CD · Congo - Kinshasa · →

Feshi fire, June 2023 Feshi

Out · last detection 20 Jun 2023, 12:57 UTC

The fire started on 12 June 2023 in Feshi, Congo - Kinshasa, and satellites saw it burning for 9 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 5,785 hectares from heat detections, spread across a single municipality.

It is the 140th largest in Kwango since 2016 (of 219 with a page). Number 46 in Congo - Kinshasa in 2023, of 76.

Burnt area
5,785ha
GWIS perimeter (Copernicus)
Duration
9days
12 Jun 2023 – 20 Jun 2023
Municipalities hit
1
territories
Started on
12 Jun
2023
Heat detections
173
in a single hotspot: 156 MW
Danger at start
4
Very low · FWI index
Energy released
2.7GW
sum of detected power

Where it burned

20 Jun 2023
HOTSPOTS BY DAY 12 Jun20 Jun

How it evolved, day by day

1213141516171920

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

33°high
31km/h · peak gust
20%lowest humidity

It had gone 0 days without rain (1 mm or more) when it started.

This area had burned before

95% of the perimeter overlaps earlier fires recorded since 2016: 1,003 ha in 2016, 2,371 ha in 2017, 3,308 ha in 2018, 3,056 ha in 2019, 1,794 ha in 2020, 1,243 ha in 2021, 791 ha in 2022. Part of it burned more than once, so the yearly figures add up to more than the 5,524 ha that had burned before.

What happened to each town

  1. Feshi where it started
    5,826 ha reached on 12 Jun
    0.3 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance is from the town centre to the nearest fire: staying a kilometre away does not mean it reached the houses.

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
12 Jun 29.3 °C 50 % 25 km/h 1.0 mm Very low 4
13 Jun 29.1 °C 52 % 24 km/h 2.7 mm Very low 2
14 Jun 26.7 °C 58 % 25 km/h 0.2 mm Very low 5
15 Jun 30.3 °C 36 % 31 km/h 0.0 mm Moderate 13
16 Jun 29.8 °C 39 % 21 km/h 0.0 mm Moderate 14
17 Jun 30.1 °C 36 % 19 km/h 0.0 mm Moderate 14
18 Jun 31.9 °C 23 % 23 km/h 0.0 mm Moderate 20
19 Jun 32.6 °C 20 % 28 km/h 0.0 mm High 25
20 Jun 30.3 °C 32 % 18 km/h 0.0 mm High 23
21 Jun after 29.5 °C 35 % 22 km/h 0.0 mm High 22
22 Jun after 30.3 °C 32 % 17 km/h 0.0 mm High 23
23 Jun after 30.0 °C 35 % 20 km/h 0.0 mm High 23
24 Jun after 30.5 °C 33 % 22 km/h 0.0 mm High 23
25 Jun after 28.9 °C 40 % 20 km/h 0.2 mm High 22
26 Jun after 27.6 °C 49 % 24 km/h 0.4 mm Moderate 19
27 Jun after 29.5 °C 44 % 17 km/h 0.2 mm Moderate 20
28 Jun after 28.4 °C 44 % 18 km/h 0.0 mm Moderate 20
29 Jun after 28.9 °C 46 % 22 km/h 0.0 mm Moderate 19
30 Jun after 28.4 °C 46 % 23 km/h 0.0 mm High 23

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 5 Jun 2023
After · 27 Jun 2023

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

Detections table · 173Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Congo - Kinshasa ›

Frequently asked questions

How long did the Feshi fire last?
GWIS (Copernicus) dates it between 12 June 2023 and 20 June 2023: 9 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 5,785 hectares (57.8 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Feshi (5,826 ha, 0.3 %).
What was the weather like?
During the fire the temperature reached 32.6 °C, humidity dropped to 20 % and gusts hit 31 km/h. The fire danger index (FWI) reached 25, class High.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Congo - Kinshasa (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.