Skip to content
worldfires
SS · South Sudan · →

Wau fire, 2 January 2025 Wau

Out · last detection 13 Jan 2025, 23:12 UTC

The fire started on 2 January 2025 in Wau, South Sudan, and satellites saw it burning for 12 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 16,185 hectares from heat detections, spread across a single municipality.

It is the 80th largest in Western Bahr el Ghazal since 2016 (of 424 with a page). Number 64 in South Sudan in 2025, of 292.

Compare with…
Burnt area
16,185ha
GWIS perimeter (Copernicus)
Duration
12days
2 Jan 2025 – 13 Jan 2025
Municipalities hit
1
counties
Started on
2 Jan
2025
Heat detections
753
in a single hotspot: 145 MW
Danger at start
54
Extreme · FWI index
Average daily power
275MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 2 Jan13 Jan
13 Jan 2025

How it evolved, day by day

2 Jan 2025 · 74 MW · 15 3 Jan 2025 · 591 MW · 38 4 Jan 2025 · 106 MW · 23 5 Jan 2025 · 192 MW · 31 6 Jan 2025 · 194 MW · 68 7 Jan 2025 · 150 MW · 32 8 Jan 2025 · 260 MW · 67 9 Jan 2025 · 646 MW · 45 10 Jan 2025 · 441 MW · 81 11 Jan 2025 · 381 MW · 158 12 Jan 2025 · 229 MW · 87 13 Jan 2025 · 32 MW · 9
2 Jan 4 Jan 6 Jan 8 Jan 9 Jan 10 Jan 12 Jan

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

38°high
38km/h · peak gust
10%lowest humidity

It had gone more than two months without rain (1 mm or more) when it started.

This area had burned before

100% of the perimeter overlaps earlier fires recorded since 2016: 13,436 ha in 2016, 7,336 ha in 2017, 8,619 ha in 2019, 5,388 ha in 2020, 3,930 ha in 2021, 3,535 ha in 2022, 2,035 ha in 2023, 1,767 ha in 2024. Part of it burned more than once, so the yearly figures add up to more than the 16,110 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 10% of the area of London (162 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Wau where it started
    16,276 ha reached on 29 Dec
    0.8 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area< 0.1 ha
Residents< 20

Inside the perimeter there was no noticeable built-up land and almost nobody lived there (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
2 Jan 34.5 °C 14 % 37 km/h 0.0 mm Extreme 54
3 Jan 35.6 °C 13 % 34 km/h 0.0 mm Extreme 52
4 Jan 37.6 °C 14 % 31 km/h 0.0 mm Extreme 51
5 Jan 38.1 °C 12 % 32 km/h 0.0 mm Extreme 51
6 Jan 36.7 °C 12 % 38 km/h 0.0 mm Extreme 56
7 Jan 34.8 °C 10 % 37 km/h 0.0 mm Extreme 56
8 Jan 36.0 °C 12 % 32 km/h 0.0 mm Extreme 53
9 Jan 36.1 °C 10 % 28 km/h 0.0 mm Extreme 51
10 Jan 36.7 °C 11 % 37 km/h 0.0 mm Extreme 56
11 Jan 35.5 °C 11 % 36 km/h 0.0 mm Extreme 58
12 Jan 33.7 °C 13 % 38 km/h 0.0 mm Extreme 57
13 Jan 34.7 °C 11 % 32 km/h 0.0 mm Extreme 53
14 Jan after 35.9 °C 11 % 34 km/h 0.0 mm Extreme 53
15 Jan after 36.5 °C 11 % 34 km/h 0.0 mm Extreme 53
16 Jan after 37.6 °C 12 % 35 km/h 0.0 mm Extreme 56
17 Jan after 38.2 °C 15 % 36 km/h 0.0 mm Extreme 56
18 Jan after 38.9 °C 14 % 37 km/h 0.0 mm Extreme 57
19 Jan after 38.5 °C 14 % 20 km/h 0.0 mm Extreme 51
20 Jan after 37.3 °C 15 % 33 km/h 0.0 mm Extreme 54
21 Jan after 36.7 °C 15 % 32 km/h 0.0 mm Extreme 53
22 Jan after 38.1 °C 9 % 26 km/h 0.0 mm Very high 49
23 Jan after 37.1 °C 11 % 32 km/h 0.0 mm Extreme 56

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 26 Dec 2024
After · 20 Jan 2025

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 5 January 2025 the air beside the fire reached 57 µg/m³ of PM2.5. That day averaged 37: 2.5 times the WHO daily guideline (15).

PM2.5 peak57 µg/m³
Days over the guideline17 days
PM1088 µg/m³
Optical depth0.67
3112345678910111213141516
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 753Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in South Sudan ›

Frequently asked questions

How long did the Wau fire last?
GWIS (Copernicus) dates it between 2 January 2025 and 13 January 2025: 12 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 16,185 hectares (161.8 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Wau (16,276 ha, 0.8 %).
What was the weather like?
During the fire the temperature reached 38.1 °C, humidity dropped to 10 % and gusts hit 38 km/h. The fire danger index (FWI) reached 58, class Extreme.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of South Sudan (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

History of this page Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.

No changes since 24 October 2026.

RSS Changes to this page

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates from the perimeter: the VIIRS detections inside it did not change them. 753 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology ›

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.