Skip to content
worldfires
GH · Ghana · →

Sunyani West fire, 22 January 2016 Sunyani West, Berekum East, Tain

Out · last detection 11 Feb 2016, 14:04 UTC

The fire started on 22 January 2016 in Sunyani West, Ghana, and satellites saw it burning for 20 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 26,650 hectares from heat detections, spread across 3 municipalities.

It is the largest fire in Bono since 2016 (of 51 with a page). The largest in Ghana in 2016, of 122.

Compare with…
Burnt area
26,650ha
GWIS perimeter (Copernicus)
Duration
20days
22 Jan 2016 – 10 Feb 2016
Municipalities hit
3
districts
Started on
22 Jan
2016
Heat detections
922
in a single hotspot: 99 MW
Danger at start
46
Very high · FWI index
Average daily power
383MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 22 Jan10 Feb
11 Feb 2016

How it evolved, day by day

22 Jan 2016 · 394 MW · 23 23 Jan 2016 · 590 MW · 46 24 Jan 2016 · 458 MW · 49 25 Jan 2016 · 124 MW · 30 26 Jan 2016 · 250 MW · 34 27 Jan 2016 · 830 MW · 75 28 Jan 2016 · 696 MW · 74 29 Jan 2016 · 584 MW · 80 30 Jan 2016 · 400 MW · 81 31 Jan 2016 · 263 MW · 50 1 Feb 2016 · 281 MW · 46 2 Feb 2016 · 539 MW · 33 3 Feb 2016 · 255 MW · 23 4 Feb 2016 · 127 MW · 25 5 Feb 2016 · 22 MW · 2 6 Feb 2016 · 1,087 MW · 54 7 Feb 2016 · 472 MW · 79 8 Feb 2016 · 334 MW · 57 9 Feb 2016 · 72 MW · 18 10 Feb 2016 · 188 MW · 27 11 Feb 2016 · 75 MW · 10
22 Jan 25 Jan 28 Jan 31 Jan 3 Feb 6 Feb 9 Feb

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

37°high
41km/h · peak gust
4%lowest humidity

It had gone more than two months without rain (1 mm or more) when it started.

This area had burned before

No earlier perimeters overlap this fire since 2016, when the satellite record begins.

How big is it?

10 km
It burned the equivalent of 17% of the area of London (266 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Sunyani West where it started
    23,426 ha reached on 22 Jan
    22 %
  2. 2,997 ha reached on 23 Jan
    6.4 %
  3. 404 ha reached on 29 Jan
    0.2 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2015
Built-up area8.4 ha
Residents≈ 350

Inside the perimeter there were about 8.4 hectares of built-up land and about 350 residents (GHSL 2015, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
22 Jan 36.1 °C 7 % 24 km/h 0.0 mm Very high 46
23 Jan 35.8 °C 6 % 34 km/h 0.0 mm Extreme 52
24 Jan 33.9 °C 4 % 41 km/h 0.0 mm Extreme 58
25 Jan 34.8 °C 10 % 26 km/h 0.0 mm Very high 50
26 Jan 32.8 °C 9 % 32 km/h 0.0 mm Extreme 52
27 Jan 34.2 °C 14 % 29 km/h 0.0 mm Very high 49
28 Jan 33.6 °C 8 % 32 km/h 0.0 mm Extreme 51
29 Jan 33.7 °C 8 % 40 km/h 0.0 mm Extreme 57
30 Jan 34.1 °C 10 % 35 km/h 0.0 mm Extreme 54
31 Jan 35.1 °C 9 % 20 km/h 0.0 mm Very high 47
1 Feb 34.8 °C 7 % 29 km/h 0.0 mm Extreme 50
2 Feb 35.1 °C 8 % 32 km/h 0.0 mm Extreme 52
3 Feb 35.4 °C 6 % 28 km/h 0.0 mm Very high 49
4 Feb 35.4 °C 13 % 22 km/h 0.0 mm Very high 46
5 Feb 34.5 °C 12 % 32 km/h 0.0 mm Extreme 52
6 Feb 37.4 °C 9 % 34 km/h 0.0 mm Extreme 53
7 Feb 36.3 °C 11 % 32 km/h 0.0 mm Extreme 54
8 Feb 36.1 °C 12 % 27 km/h 0.0 mm Extreme 52
9 Feb 36.1 °C 12 % 31 km/h 0.0 mm Extreme 52
10 Feb 36.4 °C 7 % 36 km/h 0.0 mm Extreme 58
11 Feb after 36.8 °C 9 % 21 km/h 0.0 mm Extreme 54
12 Feb after 36.7 °C 12 % 24 km/h 0.0 mm Very high 49
13 Feb after 37.4 °C 13 % 20 km/h 0.0 mm Extreme 50
14 Feb after 35.8 °C 20 % 24 km/h 0.0 mm Very high 47
15 Feb after 36.3 °C 30 % 31 km/h 0.0 mm Very high 44
16 Feb after 36.8 °C 28 % 27 km/h 0.0 mm Very high 40
17 Feb after 37.5 °C 27 % 23 km/h 0.0 mm Very high 41
18 Feb after 37.3 °C 26 % 28 km/h 0.0 mm Very high 42
19 Feb after 37.8 °C 24 % 31 km/h 0.0 mm Very high 44
20 Feb after 38.8 °C 17 % 34 km/h 0.0 mm Very high 49

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 15 Jan 2016
After · 17 Feb 2016

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

Detections table · 922Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Ghana ›

Frequently asked questions

How long did the Sunyani West fire last?
GWIS (Copernicus) dates it between 22 January 2016 and 10 February 2016: 20 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 26,650 hectares (266.5 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire entered 3 municipalities: Sunyani West (23,426 ha, 22 %); Berekum East (2,997 ha, 6.4 %); Tain (404 ha, 0.2 %).
What was the weather like?
During the fire the temperature reached 37.4 °C, humidity dropped to 4 % and gusts hit 41 km/h. The fire danger index (FWI) reached 58, class Extreme.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Ghana (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Emergency number: 112 · Emergency number and official warnings ›

Satellite cross-check

History of this page Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.

No changes since 24 October 2026.

RSS Changes to this page

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy. This is not an emergency service: if there is a fire now, call 112.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery; 3 polygons grouped in this page.
  • Dates from the perimeter: the VIIRS detections inside it did not change them. 922 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2015, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology ›

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 4.0 International (CC BY 4.0)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.