Skip to content
worldfires
CN · China · →

Suileng County fire, March 2026 Suileng County, Hailun City

Out · last detection 4 Apr 2026, 04:45 UTC

The fire started on 31 March 2026 in Suileng County, China, and satellites saw it burning for 5 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 3,283 hectares from heat detections, spread across 2 municipalities.

It is the 287th largest in Heilongjiang Province since 2016 (of 1761 with a page). Number 183 in China in 2026, of 890.

Compare with…
Burnt area
3,283ha
GWIS perimeter (Copernicus)
Duration
5days
31 Mar 2026 – 4 Apr 2026
Municipalities hit
2
counties
Started on
31 Mar
2026
Heat detections
95
in a single hotspot: 63 MW
Danger at start
6
Low · FWI index
Average daily power
538MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 31 Mar4 Apr
4 Apr 2026

How it evolved, day by day

31 Mar 2026 · 29 MW · 8 1 Apr 2026 · 501 MW · 35 4 Apr 2026 · 1,083 MW · 44
31 Mar 1 Apr 4 Apr

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

12°high
46km/h · peak gust
21%lowest humidity

It had gone 23 days without rain (1 mm or more) when it started. Rain came after the fire: 3.8 mm on 5 Apr.

This area had burned before

6% of the perimeter overlaps earlier fires recorded since 2016: 201 ha in 2024.

How big is it?

10 km
It burned the equivalent of 2.1% of the area of London (33 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Suileng County where it started
    3,243 ha
    0.8 %
  2. Hailun City 海伦市
    21 ha
    0.0 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area55 ha
Residents≈ 5,100

Inside the perimeter there were about 55 hectares of built-up land and about 5,100 residents (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
27 Mar 11.5 °C 32 % 35 km/h 0.0 mm Low 6
28 Mar 11.7 °C 27 % 32 km/h 0.0 mm Low 6
29 Mar 9.5 °C 43 % 46 km/h 0.6 mm Low 6
30 Mar 9.9 °C 39 % 39 km/h 0.8 mm Very low 4
31 Mar 12.4 °C 32 % 39 km/h 0.0 mm Low 5
1 Apr 6.2 °C 21 % 46 km/h 0.0 mm Low 8
2 Apr 8.6 °C 23 % 37 km/h 0.2 mm Low 8
3 Apr 5.4 °C 27 % 27 km/h 0.1 mm Low 7
4 Apr 8.1 °C 27 % 21 km/h 0.0 mm Low 6
5 Apr after 4.0 °C 49 % 53 km/h 3.8 mm Very low 1

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 24 Mar 2026
After · 11 Apr 2026

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 31 March 2026 the air beside the fire reached 81 µg/m³ of PM2.5. That day averaged 50: 3.3 times the WHO daily guideline (15).

PM2.5 peak81 µg/m³
Days over the guideline10 days
PM10101 µg/m³
Optical depth1.27
2930311234567
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 95Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in China ›

Frequently asked questions

How long did the Suileng County fire last?
GWIS (Copernicus) dates it between 31 March 2026 and 4 April 2026: 5 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 3,283 hectares (32.8 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire entered 2 municipalities: Suileng County (3,243 ha, 0.8 %); Hailun City (21 ha, 0.0 %).
What was the weather like?
During the fire the temperature reached 12.4 °C, humidity dropped to 21 % and gusts hit 46 km/h. The fire danger index (FWI) reached 8, class Low.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of China (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Emergency number: 119 · Emergency number and official warnings ›

Satellite cross-check

History of this page Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.

No changes since 24 October 2026.

RSS Changes to this page

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy. This is not an emergency service: if there is a fire now, call 119.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates from the perimeter: the VIIRS detections inside it did not change them. 95 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology ›

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM3 (Open Data Commons Open Database License 1.0). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.