Skip to content
worldfires
GH · Ghana · –

Sene East fire, 13 January 2024 Sene East

Out · last detection 27 Jan 2024, 01:12 UTC

The fire started on 13 January 2024 in Sene East, Ghana, and satellites saw it burning for 15 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 4,149 hectares from heat detections, spread across a single municipality.

It is the 31th largest in Bono East since 2016 (of 153 with a page). Number 21 in Ghana in 2024, of 115.

Burnt area
4,149ha
GWIS perimeter (Copernicus)
Duration
15days
13 Jan 2024 – 27 Jan 2024
Municipalities hit
1
districts
Started on
13 Jan
2024
Heat detections
121
in a single hotspot: 104 MW
Danger at start
20
Moderate · FWI index
Average daily power
99MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 13 Jan27 Jan
27 Jan 2024

How it evolved, day by day

13 Jan 2024 · 185 MW · 5 15 Jan 2024 · 33 MW · 7 16 Jan 2024 · 236 MW · 30 17 Jan 2024 · 543 MW · 38 18 Jan 2024 · 59 MW · 13 19 Jan 2024 · 43 MW · 13 20 Jan 2024 · 24 MW · 2 22 Jan 2024 · 27 MW · 6 23 Jan 2024 · 5 MW · 1 24 Jan 2024 · 32 MW · 2 26 Jan 2024 · 2 MW · 2 27 Jan 2024 · 4 MW · 2
13 Jan 17 Jan 20 Jan 24 Jan

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

35°high
33km/h · peak gust
24%lowest humidity

It had gone 46 days without rain (1 mm or more) when it started.

This area had burned before

64% of the perimeter overlaps earlier fires recorded since 2016: 554 ha in 2017, 1,085 ha in 2018, 1,236 ha in 2019, 843 ha in 2021, 1,787 ha in 2022, 1,309 ha in 2023. Part of it burned more than once, so the yearly figures add up to more than the 2,649 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 2.6% of the area of London (41 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Sene East where it started
    4,175 ha reached on 13 Jan
    0.9 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area0.76 ha
Residents≈ 80

Inside the perimeter there were about 0.76 hectares of built-up land and about 80 residents (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
13 Jan 33.7 °C 41 % 19 km/h 0.0 mm Moderate 20
14 Jan 33.8 °C 48 % 23 km/h 0.0 mm Moderate 18
15 Jan 34.0 °C 40 % 20 km/h 0.0 mm Moderate 20
16 Jan 33.8 °C 29 % 20 km/h 0.0 mm High 25
17 Jan 34.5 °C 26 % 22 km/h 0.0 mm High 30
18 Jan 33.8 °C 37 % 23 km/h 0.0 mm High 26
19 Jan 34.6 °C 39 % 26 km/h 0.0 mm High 22
20 Jan 33.2 °C 36 % 23 km/h 0.0 mm High 26
21 Jan 33.9 °C 39 % 22 km/h 0.0 mm Moderate 21
22 Jan 35.1 °C 35 % 22 km/h 0.0 mm High 24
23 Jan 33.3 °C 52 % 33 km/h 0.0 mm High 22
24 Jan 34.8 °C 42 % 30 km/h 0.0 mm Moderate 21
25 Jan 33.9 °C 34 % 23 km/h 0.0 mm High 26
26 Jan 33.5 °C 24 % 20 km/h 0.4 mm High 31
27 Jan 33.3 °C 24 % 22 km/h 0.0 mm High 38
28 Jan after 32.9 °C 25 % 22 km/h 0.0 mm High 37
29 Jan after 33.8 °C 22 % 19 km/h 0.0 mm High 35
30 Jan after 34.5 °C 26 % 16 km/h 0.0 mm High 33
31 Jan after 34.1 °C 35 % 24 km/h 0.0 mm High 28
1 Feb after 34.5 °C 43 % 25 km/h 0.0 mm High 23
2 Feb after 34.0 °C 30 % 20 km/h 0.0 mm High 26
3 Feb after 34.2 °C 23 % 21 km/h 0.0 mm Very high 42
4 Feb after 33.2 °C 26 % 18 km/h 0.0 mm Very high 40
5 Feb after 33.4 °C 26 % 20 km/h 0.0 mm Very high 40
6 Feb after 33.4 °C 26 % 19 km/h 0.0 mm Very high 38

Its twins: fires that started in the same weather

It started with an FWI of 20.5, a minimum humidity of 41% and 46 days without rain. Fires in the area that started in weather like this since 2016: 20.

FWI at the start 20.5
Minimum humidity 41 %
Days without rain 46
this fire chosen twins rest of the area
Almost identicalSimilar

Outlines of the closest twins

Sene East fire, January 2021
3,745 ha 4 days FWI 27.4 Min. humidity 39 % 36 km away, in 2021

First rain (1 mm or more) after it ended: none in the following ten days.

What happened to them

12 days
median duration
3,168 ha
median area
5 %
went past 10,000 ha
2.8 mm
rain at the end (median; 3 of 20 had it)

It burned an area similar to its twins (4,149 ha against a median of 3,168 ha) and lasted 15 days, against 12 days.

In 17 of 20, not even 1 mm fell in the ten days after the end: they went out without rain. In the rest, the first rainy day brought a median of 2.8 mm.

This is a bank of analogues: it shows what usually happens, not what will happen. With fewer than 15 twins we give no figures. How we calculate it

How it ended

—first rain
—no rain in ten days
33km/h · max. gust

It was considered over on 27 Jan, and not even 1 mm fell in the following ten days: it went out without rain. Twins with rain when they ended: 3 of 20, with a median of 2.8 mm.

Weather on this page: Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

How a twin is chosen

  • Same area: fires that have already ended, less than 250 km from this one, since 2016.
  • Same start: we compare the FWI on the first day, the minimum humidity that day and the run of days without rain before it. The slider sets how much they may differ.
  • Only pages with final weather data (ERA5 reanalysis) calculated in the same way as this fire’s; agricultural and grass burns and pages with data under review are left out.
  • Fires burning at the same time as this one (a week before or after) are left out: they share the same spell of weather and do not count as a precedent.
  • They are sorted by similarity, and the outlines of the first five are drawn.

How we calculate it

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 6 Jan 2024
After · 3 Feb 2024

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 17 January 2024 the air beside the fire reached 144 µg/m³ of PM2.5. That day averaged 106: 7.1 times the WHO daily guideline (15).

PM2.5 peak144 µg/m³
Days over the guideline15 days
PM10331 µg/m³
Optical depth1.28
11 Jan14 Jan17 Jan20 Jan23 Jan
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 121Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Ghana

Frequently asked questions

How long did the Sene East fire last?
According to the heat detections seen by satellite inside the perimeter, it burned from 13 January 2024 to 27 January 2024 (15 days). The perimeter dates it from 13 January 2024 to 22 January 2024.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 4,149 hectares (41.5 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Sene East (4,175 ha, 0.9 %).
What was the weather like?
During the fire the temperature reached 35.1 °C, humidity dropped to 24 % and gusts hit 33 km/h. The fire danger index (FWI) reached 38, class High.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Ghana (geoBoundaries). It is not an official report.
How did the fires that started in similar weather in this area end?
Fires less than 250 km away that started since 2016 with a similar FWI, humidity and dry spell: 20. Their median duration was 12 days and their median area 3,168 ha; 5 % went past 10,000 ha. In 17 of 20, not even 1 mm fell in the ten days after the end: they went out without rain. In the rest, the first rainy day brought a median of 2.8 mm.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Emergency number: 112 · Emergency number and official warnings

Satellite cross-check

History of this page · 1 Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.
  1. Last day with fire: 22 January 2024 → 27 January 2024.

RSS Changes to this page With cross-checks and a citable version

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy. This is not an emergency service: if there is a fire now, call 112.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates adjusted with the VIIRS detections inside the perimeter, which said 13 January 2024 to 22 January 2024. 121 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 4.0 International (CC BY 4.0)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.