Skip to content
worldfires
GT · Guatemala · →

Senahú fire, April 2024 Senahú, Santa Catalina La Tinta, Tucurú

Out · last detection 29 Apr 2024, 18:21 UTC

The fire started on 25 April 2024 in Senahú, Guatemala, and satellites saw it burning for 5 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 1,167 hectares from heat detections, spread across 3 municipalities.

It is the 13th largest in Alta Verapaz since 2016 (of 24 with a page). Number 53 in Guatemala in 2024, of 70.

Burnt area
1,167ha
GWIS perimeter (Copernicus)
Duration
5days
25 Apr 2024 – 29 Apr 2024
Municipalities hit
3
municipalities
Started on
25 Apr
2024
Heat detections
46
in a single hotspot: 39 MW
Danger at start
8
Low · FWI index
Energy released
248MW
sum of detected power

Where it burned

29 Apr 2024
HOTSPOTS BY DAY 25 Apr29 Apr

How it evolved, day by day

2526272829

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

37°high
44km/h · peak gust
44%lowest humidity

It had gone 0 days without rain (1 mm or more) when it started. Rain came after the fire: 4.3 mm on 30 Apr.

This area had burned before

25% of the perimeter overlaps earlier fires recorded since 2016: 292 ha in 2021.

What happened to each town

  1. Senahú where it started
    667 ha reached on 21 Apr
    0.9 %
  2. 300 ha reached on 26 Apr
    1.5 %
  3. Tucurú 28,421 inhabitants
    207 ha reached on 19 Apr
    0.9 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance is from the town centre to the nearest fire: staying a kilometre away does not mean it reached the houses.

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
25 Apr 30.9 °C 59 % 44 km/h 0.9 mm Low 8
26 Apr 34.0 °C 46 % 43 km/h 0.0 mm Moderate 14
27 Apr 34.9 °C 53 % 31 km/h 0.7 mm Moderate 12
28 Apr 34.6 °C 53 % 26 km/h 7.1 mm Very low 2
29 Apr 37.1 °C 44 % 27 km/h 2.4 mm Very low 4
30 Apr after 34.7 °C 59 % 34 km/h 4.3 mm Very low 2

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 18 Apr 2024
After · 6 May 2024

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 28 April 2024 the air beside the fire reached 49 µg/m³ of PM2.5. That day averaged 33: 2.2 times the WHO daily guideline (15).

PM2.5 peak49 µg/m³
Days over the guideline6 days
PM1071 µg/m³
Optical depth1.66
232425262728293012
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 46Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Guatemala ›

Frequently asked questions

How long did the Senahú fire last?
GWIS (Copernicus) dates it between 25 April 2024 and 29 April 2024: 5 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 1,167 hectares (11.7 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire entered 3 municipalities: Senahú (667 ha, 0.9 %); Santa Catalina La Tinta (300 ha, 1.5 %); Tucurú (207 ha, 0.9 %).
What was the weather like?
During the fire the temperature reached 37.1 °C, humidity dropped to 44 % and gusts hit 44 km/h. The fire danger index (FWI) reached 14, class Moderate.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Guatemala (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Emergency number: 122 · 123 · 1566

Satellite cross-check

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy. This is not an emergency service: if there is a fire now, call 122 · 123 · 1566.

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.