Skip to content
worldfires
BO · Bolivia · →

San Joaquín fire, 3 October 2023 San Joaquín

Out · last detection 17 Oct 2023, 04:54 UTC

The fire started on 3 October 2023 in San Joaquín, Bolivia, and satellites saw it burning for 15 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 7,429 hectares from heat detections, spread across a single municipality.

It is the 250th largest in Beni since 2016 (of 904 with a page). Number 81 in Bolivia in 2023, of 248.

Compare with…
Burnt area
7,429ha
GWIS perimeter (Copernicus)
Duration
15days
3 Oct 2023 – 17 Oct 2023
Municipalities hit
1
municipalities
Started on
3 Oct
2023
Heat detections
454
in a single hotspot: 552 MW
Danger at start
16
Moderate · FWI index
Average daily power
655MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 3 Oct17 Oct
17 Oct 2023

How it evolved, day by day

3 Oct 2023 · 183 MW · 5 4 Oct 2023 · 1,720 MW · 22 5 Oct 2023 · 846 MW · 38 6 Oct 2023 · 529 MW · 18 7 Oct 2023 · 650 MW · 46 8 Oct 2023 · 121 MW · 25 9 Oct 2023 · 153 MW · 14 10 Oct 2023 · 175 MW · 15 11 Oct 2023 · 164 MW · 8 13 Oct 2023 · 8 MW · 4 14 Oct 2023 · 1,151 MW · 66 15 Oct 2023 · 1,293 MW · 118 16 Oct 2023 · 2,157 MW · 69 17 Oct 2023 · 17 MW · 6
3 Oct 5 Oct 7 Oct 9 Oct 11 Oct 14 Oct 16 Oct

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

37°high
55km/h · peak gust
37%lowest humidity

It had gone one day without rain (1 mm or more) when it started. Rain came after the fire: 1.1 mm on 19 Oct.

This area had burned before

53% of the perimeter overlaps earlier fires recorded since 2016: 792 ha in 2017, 3,832 ha in 2020, 507 ha in 2022. Part of it burned more than once, so the yearly figures add up to more than the 3,925 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 4.7% of the area of London (74 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. San Joaquín 6,808 inhabitants where it started
    7,476 ha reached on 3 Oct
    0.9 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area< 0.1 ha
Residents< 20

Inside the perimeter there was no noticeable built-up land and almost nobody lived there (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
3 Oct 36.4 °C 45 % 42 km/h 0.0 mm Moderate 16
4 Oct 37.0 °C 43 % 45 km/h 0.0 mm Moderate 17
5 Oct 36.2 °C 47 % 46 km/h 0.2 mm Moderate 19
6 Oct 37.2 °C 42 % 55 km/h 0.0 mm Moderate 21
7 Oct 37.2 °C 44 % 46 km/h 0.4 mm Moderate 20
8 Oct 30.8 °C 68 % 34 km/h 9.0 mm Very low 1
9 Oct 32.8 °C 54 % 24 km/h 0.2 mm Very low 5
10 Oct 35.2 °C 51 % 28 km/h 0.0 mm Low 10
11 Oct 36.5 °C 46 % 34 km/h 0.0 mm Moderate 14
12 Oct 34.7 °C 53 % 28 km/h 7.3 mm Very low 2
13 Oct 29.6 °C 66 % 34 km/h 4.2 mm Very low 1
14 Oct 33.8 °C 45 % 25 km/h 0.1 mm Low 6
15 Oct 37.1 °C 37 % 21 km/h 0.3 mm Moderate 12
16 Oct 36.2 °C 45 % 33 km/h 0.6 mm Moderate 13
17 Oct 35.6 °C 44 % 31 km/h 0.0 mm Moderate 14
18 Oct after 37.3 °C 42 % 25 km/h 0.8 mm Moderate 12
19 Oct after 38.8 °C 37 % 19 km/h 1.1 mm Moderate 12

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 26 Sept 2023
After · 24 Oct 2023

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 15 October 2023 the air beside the fire reached 107 µg/m³ of PM2.5. That day averaged 68: 4.6 times the WHO daily guideline (15).

PM2.5 peak107 µg/m³
Days over the guideline16 days
PM10153 µg/m³
Optical depth2.16
234567891011121314151617181920
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 454Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Bolivia ›

Frequently asked questions

How long did the San Joaquín fire last?
According to the heat detections seen by satellite inside the perimeter, it burned from 3 October 2023 to 17 October 2023 (15 days). The perimeter dates it from 4 October 2023 to 17 October 2023.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 7,429 hectares (74.3 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered San Joaquín (7,476 ha, 0.9 %).
What was the weather like?
During the fire the temperature reached 37.2 °C, humidity dropped to 37 % and gusts hit 55 km/h. The fire danger index (FWI) reached 21, class Moderate.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Bolivia (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Emergency number: 119 · 110 · Emergency number and official warnings ›

Satellite cross-check

History of this page Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.

No changes since 24 October 2026.

RSS Changes to this page

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy. This is not an emergency service: if there is a fire now, call 119 · 110.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates adjusted with the VIIRS detections inside the perimeter, which said 4 October 2023 to 17 October 2023. 454 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology ›

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM3 (Public Domain). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.