Skip to content
worldfires
BO · Bolivia · –

San Ignacio fire, 22 September 2024 San Ignacio, Loreto

Out · last detection 5 Oct 2024, 18:28 UTC

The fire started on 22 September 2024 in San Ignacio, Bolivia, and satellites saw it burning for 14 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 3,160 hectares from heat detections, spread across 2 municipalities.

It is the 802th largest in Beni since 2016 (of 858 with a page). Number 275 in Bolivia in 2024, of 295.

Burnt area
3,160ha
GWIS perimeter (Copernicus)
Duration
14days
22 Sept 2024 – 5 Oct 2024
Municipalities hit
2
municipalities
Started on
22 Sept
2024
Heat detections
262
in a single hotspot: 61 MW
Danger at start
29
High · FWI index
Average daily power
219MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 22 Sept5 Oct
5 Oct 2024

How it evolved, day by day

22 Sept 2024 · 335 MW · 9 23 Sept 2024 · 1,567 MW · 62 24 Sept 2024 · 351 MW · 56 25 Sept 2024 · 401 MW · 62 26 Sept 2024 · 156 MW · 27 27 Sept 2024 · 4 MW · 1 28 Sept 2024 · 7 MW · 3 29 Sept 2024 · 5 MW · 1 30 Sept 2024 · 3 MW · 1 1 Oct 2024 · 104 MW · 15 2 Oct 2024 · 66 MW · 11 3 Oct 2024 · 2 MW · 1 4 Oct 2024 · 36 MW · 8 5 Oct 2024 · 31 MW · 5
23 Sept 28 Sept 1 Oct 4 Oct

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

40°high
50km/h · peak gust
28%lowest humidity

It had gone 6 days without rain (1 mm or more) when it started. Rain came after the fire: 2.4 mm on 8 Oct.

This area had burned before

80% of the perimeter overlaps earlier fires recorded since 2016: 548 ha in 2017, 834 ha in 2018, 1,516 ha in 2019, 1,058 ha in 2020, 1,257 ha in 2022, 1,081 ha in 2023. Part of it burned more than once, so the yearly figures add up to more than the 2,534 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 2% of the area of London (32 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. San Ignacio 21,584 inhabitants where it started
    3,134 ha
    0.1 %
  2. Loreto 4,269 inhabitants
    47 ha
    0.0 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area< 0.1 ha
Residents< 20

Inside the perimeter there was no noticeable built-up land and almost nobody lived there (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
22 Sept 40.5 °C 30 % 40 km/h 0.0 mm High 29
23 Sept 39.6 °C 33 % 48 km/h 0.0 mm High 33
24 Sept 40.4 °C 30 % 42 km/h 0.0 mm High 30
25 Sept 39.4 °C 36 % 45 km/h 0.1 mm High 32
26 Sept 37.3 °C 39 % 35 km/h 14.3 mm High 26
27 Sept 27.6 °C 49 % 36 km/h 3.1 mm Very low 3
28 Sept 34.1 °C 40 % 18 km/h 0.0 mm Very low 3
29 Sept 37.4 °C 34 % 25 km/h 0.1 mm Moderate 16
30 Sept 37.6 °C 41 % 45 km/h 0.1 mm High 24
1 Oct 37.9 °C 38 % 50 km/h 0.0 mm High 29
2 Oct 38.1 °C 40 % 42 km/h 0.0 mm High 25
3 Oct 31.4 °C 39 % 37 km/h 6.1 mm Low 6
4 Oct 34.3 °C 32 % 33 km/h 0.0 mm Moderate 19
5 Oct 39.0 °C 28 % 25 km/h 0.0 mm High 22
6 Oct after 39.8 °C 30 % 34 km/h 0.0 mm High 27
7 Oct after 39.1 °C 35 % 45 km/h 0.0 mm High 32
8 Oct after 38.4 °C 40 % 53 km/h 2.4 mm High 34

Its twins: fires that started in the same weather

It started with an FWI of 28.8, a minimum humidity of 30% and 6 days without rain. Fires in the area that started in weather like this since 2016: 15.

FWI at the start 28.8
Minimum humidity 30 %
Days without rain 6
this fire chosen twins rest of the area
Almost identicalSimilar

Outlines of the closest twins

Loreto fire, September 2022
3,972 ha 10 days FWI 28.4 Min. humidity 32 % 41 km away, in 2022

First rain (1 mm or more) after it ended: 1.3 mm on 13 Sept.

What happened to them

10 days
median duration
4,535 ha
median area
20 %
went past 10,000 ha
8.2 mm
rain at the end (median; 14 of 15 had it)

It burned an area similar to its twins (3,160 ha against a median of 4,535 ha) and lasted 14 days, against 10 days.

In 1 of 15, not even 1 mm fell in the ten days after the end: they went out without rain. In the rest, the first rainy day brought a median of 8.2 mm.

This is a bank of analogues: it shows what usually happens, not what will happen. With fewer than 15 twins we give no figures. How we calculate it

How it ended

2.4 mmfirst rain
8 Oct3 days after it ended
50km/h · max. gust

It was considered over on 5 Oct, and on 8 Oct 2.4 mm fell. We do not know whether the rain or the firefighters put it out. Twins with rain when they ended: 14 of 15, with a median of 8.2 mm.

Weather on this page: Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

How a twin is chosen

  • Same area: fires that have already ended, less than 250 km from this one, since 2016.
  • Same start: we compare the FWI on the first day, the minimum humidity that day and the run of days without rain before it. The slider sets how much they may differ.
  • Only pages with final weather data (ERA5 reanalysis) calculated in the same way as this fire’s; agricultural and grass burns and pages with data under review are left out.
  • Fires burning at the same time as this one (a week before or after) are left out: they share the same spell of weather and do not count as a precedent.
  • They are sorted by similarity, and the outlines of the first five are drawn.

How we calculate it

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 15 Sept 2024
After · 12 Oct 2024

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 21 September 2024 the air beside the fire reached 139 µg/m³ of PM2.5. That day averaged 108: 7.2 times the WHO daily guideline (15).

PM2.5 peak139 µg/m³
Days over the guideline12 days
PM10199 µg/m³
Optical depth4.42
20 Sept23 Sept26 Sept29 Sept
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 262Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Bolivia

Frequently asked questions

How long did the San Ignacio fire last?
According to the heat detections seen by satellite inside the perimeter, it burned from 22 September 2024 to 5 October 2024 (14 days). The perimeter dates it from 22 September 2024 to 28 September 2024.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 3,160 hectares (31.6 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire entered 2 municipalities: San Ignacio (3,134 ha, 0.1 %); Loreto (47 ha, 0.0 %).
What was the weather like?
During the fire the temperature reached 40.5 °C, humidity dropped to 28 % and gusts hit 50 km/h. The fire danger index (FWI) reached 33, class High.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Bolivia (geoBoundaries). It is not an official report.
How did the fires that started in similar weather in this area end?
Fires less than 250 km away that started since 2016 with a similar FWI, humidity and dry spell: 15. Their median duration was 10 days and their median area 4,535 ha; 20 % went past 10,000 ha. In 1 of 15, not even 1 mm fell in the ten days after the end: they went out without rain. In the rest, the first rainy day brought a median of 8.2 mm.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Emergency number: 119 · 110 · Emergency number and official warnings

Satellite cross-check

History of this page · 1 Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.
  1. Last day with fire: 28 September 2024 → 5 October 2024.

RSS Changes to this page With cross-checks and a citable version

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy. This is not an emergency service: if there is a fire now, call 119 · 110.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates adjusted with the VIIRS detections inside the perimeter, which said 22 September 2024 to 28 September 2024. 262 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM3 (Public Domain). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.