Nyaungshwe fire, 13 February 2026 Nyaungshwe

Out · last detection 23 Feb 2026, 07:08 UTC

The fire started on 13 February 2026 in Nyaungshwe, Myanmar, and satellites saw it burning for 11 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 4,550 hectares from heat detections, spread across a single municipality.

Number 149 in Myanmar in 2026, of 480.

GWIS near-real-time perimeter, from the layer that changed in October 2025: this fire is not compared with fires from earlier years, because since then the GWIS layer gives more and larger perimeters.

Burnt area
4,550ha
GWIS perimeter (Copernicus)
Duration
11days
13 Feb 2026 – 23 Feb 2026
Municipalities hit
1
municipalities
Started on
13 Feb
2026
Heat detections
84
in a single hotspot: 43 MW
Danger at start
30
High · FWI index
Average daily power
92MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 13 Feb23 Feb
23 Feb 2026

How it evolved, day by day

13 Feb 2026 · 44 MW · 10 14 Feb 2026 · 122 MW · 10 15 Feb 2026 · 176 MW · 16 16 Feb 2026 · 190 MW · 14 17 Feb 2026 · 107 MW · 11 18 Feb 2026 · 100 MW · 10 19 Feb 2026 · 62 MW · 9 22 Feb 2026 · 13 MW · 2 23 Feb 2026 · 12 MW · 2
13 Feb 16 Feb 19 Feb 23 Feb

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

32°high
41km/h · peak gust
18%lowest humidity

It had gone more than two months without rain (1 mm or more) when it started. Rain came after the fire: 3.1 mm on 25 Feb.

This area had burned before

89% of the perimeter overlaps earlier fires recorded since 2016: 683 ha in 2016, 2,177 ha in 2017, 935 ha in 2019, 1,417 ha in 2020, 984 ha in 2021, 299 ha in 2022, 1,761 ha in 2023, 1,368 ha in 2024, 553 ha in 2025. Part of it burned more than once, so the yearly figures add up to more than the 4,063 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 2.9% of the area of London (46 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Nyaungshwe where it started
    4,567 ha reached on 13 Feb
    3.1 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area1.6 ha
Residents≈ 600

Inside the perimeter there were about 1.6 hectares of built-up land and about 600 residents (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Started with 60 days without rain: 24 % of the area in Myanmar

Day High Min. humidity Peak gust Rain Danger (FWI)
13 Feb 30.2 °C 23 % 22 km/h 0.0 mm High 30
14 Feb 30.4 °C 24 % 26 km/h 0.0 mm High 33
15 Feb 30.7 °C 18 % 31 km/h 0.0 mm High 37
16 Feb 31.0 °C 19 % 20 km/h 0.0 mm High 34
17 Feb 31.2 °C 24 % 28 km/h 0.0 mm High 38
18 Feb 32.1 °C 27 % 21 km/h 0.0 mm High 33
19 Feb 31.0 °C 34 % 22 km/h 0.3 mm High 29
20 Feb 29.8 °C 38 % 24 km/h 0.0 mm High 29
21 Feb 29.2 °C 40 % 38 km/h 1.0 mm High 36
22 Feb 28.4 °C 36 % 41 km/h 0.2 mm High 28
23 Feb 29.3 °C 31 % 29 km/h 0.0 mm High 26
24 Feb after 26.6 °C 35 % 30 km/h 0.6 mm High 26
25 Feb after 21.6 °C 73 % 31 km/h 3.1 mm Very low 4

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 6 Feb 2026
After · 2 Mar 2026

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 22 February 2026 the air beside the fire reached 75 µg/m³ of PM2.5. That day averaged 44: 3.0 times the WHO daily guideline (15).

PM2.5 peak75 µg/m³
Days over the guideline12 days
PM1076 µg/m³
Optical depth1.03
11 Feb14 Feb17 Feb20 Feb23 Feb
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 84Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Myanmar

Frequently asked questions

How long did the Nyaungshwe fire last?
According to the heat detections seen by satellite inside the perimeter, it burned from 13 February 2026 to 23 February 2026 (11 days). The perimeter dates it from 13 February 2026 to 20 February 2026.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 4,550 hectares (45.5 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Nyaungshwe (4,567 ha, 3.1 %).
What was the weather like?
During the fire the temperature reached 32.1 °C, humidity dropped to 18 % and gusts hit 41 km/h. The fire danger index (FWI) reached 38, class High.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Myanmar (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

History of this page · 1 Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.
  1. Last day with fire: 20 February 2026 → 23 February 2026.

RSS Changes to this page With cross-checks and a citable version

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates adjusted with the VIIRS detections inside the perimeter, which said 13 February 2026 to 20 February 2026. 84 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM3 (Creative Commons Attribution 4.0 (CC BY 4.0)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.