Skip to content
worldfires
BF · Burkina Faso · –

Niangoloko fire, 4 January 2024 Niangoloko

Out · last detection 15 Jan 2024, 14:23 UTC

The fire started on 4 January 2024 in Niangoloko, Burkina Faso, and satellites saw it burning for 12 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 1,418 hectares from heat detections, spread across a single municipality.

It is the 52th largest in Tannounyan since 2016 (of 113 with a page). Number 224 in Burkina Faso in 2024, of 380.

The power measured by the satellite is low (17.4 MW in the strongest hotspot), more typical of grass or stubble burning, or a slow surface fire, than of a large crown fire.

Burnt area
1,418ha
GWIS perimeter (Copernicus)
Duration
12days
4 Jan 2024 – 15 Jan 2024
Municipalities hit
1
communes
Started on
4 Jan
2024
Heat detections
40
in a single hotspot: 17 MW
Danger at start
42
Very high · FWI index
Average daily power
38MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 4 Jan15 Jan
15 Jan 2024

How it evolved, day by day

4 Jan 2024 · 37 MW · 7 6 Jan 2024 · 16 MW · 3 9 Jan 2024 · 16 MW · 2 11 Jan 2024 · 63 MW · 13 12 Jan 2024 · 39 MW · 4 13 Jan 2024 · 16 MW · 2 14 Jan 2024 · 107 MW · 7 15 Jan 2024 · 7 MW · 2
4 Jan 9 Jan 12 Jan 14 Jan

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

37°high
32km/h · peak gust
12%lowest humidity

It had gone 36 days without rain (1 mm or more) when it started.

This area had burned before

No earlier perimeters overlap this fire since 2016, when the satellite record begins.

How big is it?

10 km
It burned the equivalent of 0.9% of the area of London (14 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Niangoloko where it started
    1,427 ha reached on 4 Jan
    0.5 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area1.7 ha
Residents≈ 200

Inside the perimeter there were about 1.7 hectares of built-up land and about 200 residents (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Started with Very dry air: 56 % of the area in Burkina Faso

Day High Min. humidity Peak gust Rain Danger (FWI)
4 Jan 35.7 °C 13 % 23 km/h 0.0 mm Very high 42
5 Jan 36.1 °C 17 % 21 km/h 0.0 mm Very high 43
6 Jan 35.5 °C 20 % 24 km/h 0.0 mm Very high 43
7 Jan 35.5 °C 21 % 25 km/h 0.0 mm Very high 43
8 Jan 36.6 °C 17 % 32 km/h 0.0 mm Very high 46
9 Jan 35.6 °C 25 % 22 km/h 0.0 mm Very high 40
10 Jan 36.0 °C 29 % 19 km/h 0.0 mm High 38
11 Jan 35.6 °C 22 % 26 km/h 0.0 mm Very high 39
12 Jan 35.4 °C 19 % 30 km/h 0.0 mm Very high 40
13 Jan 35.9 °C 14 % 32 km/h 0.0 mm Very high 47
14 Jan 37.0 °C 12 % 27 km/h 0.0 mm Very high 47
15 Jan 35.3 °C 19 % 25 km/h 0.0 mm Very high 46
16 Jan after 35.1 °C 17 % 25 km/h 0.0 mm Very high 45
17 Jan after 35.5 °C 14 % 28 km/h 0.0 mm Very high 48
18 Jan after 35.3 °C 16 % 27 km/h 0.0 mm Very high 47
19 Jan after 35.3 °C 19 % 18 km/h 0.0 mm Very high 44
20 Jan after 36.4 °C 18 % 20 km/h 0.0 mm Very high 44
21 Jan after 36.3 °C 17 % 31 km/h 0.0 mm Extreme 51
22 Jan after 36.8 °C 14 % 27 km/h 0.0 mm Very high 48
23 Jan after 36.5 °C 12 % 29 km/h 0.0 mm Very high 49
24 Jan after 35.6 °C 16 % 26 km/h 0.0 mm Very high 46
25 Jan after 35.0 °C 13 % 36 km/h 0.0 mm Extreme 54

Its twins: fires that started in the same weather

It started with an FWI of 42.5, a minimum humidity of 13% and 36 days without rain. Fires in the area that started in weather like this since 2016: 38.

FWI at the start 42.5
Minimum humidity 13 %
Days without rain 36
this fire chosen twins rest of the area
Almost identicalSimilar

Outlines of the closest twins

Parc national de la Comoé fire, December 2018
1,669 ha 11 days FWI 42.7 Min. humidity 13 % 188 km away, in 2018

First rain (1 mm or more) after it ended: none in the following ten days.

What happened to them

5 days
median duration
1,726 ha
median area
100 %
went past 1,000 ha
—
rain at the end (median; 0 of 38 had it)

It burned an area similar to its twins (1,418 ha against a median of 1,726 ha) and lasted 12 days, against 5 days.

In none of them did 1 mm fall in the ten days after the end: they all went out without rain.

This is a bank of analogues: it shows what usually happens, not what will happen. With fewer than 15 twins we give no figures. How we calculate it

How it ended

—first rain
—no rain in ten days
32km/h · max. gust

It was considered over on 15 Jan, and not even 1 mm fell in the following ten days: it went out without rain. None of its 38 twins had rain when they ended.

Weather on this page: Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

How a twin is chosen

  • Same area: fires that have already ended, less than 250 km from this one, since 2016.
  • Same start: we compare the FWI on the first day, the minimum humidity that day and the run of days without rain before it. The slider sets how much they may differ.
  • Only pages with final weather data (ERA5 reanalysis) calculated in the same way as this fire’s; agricultural and grass burns and pages with data under review are left out.
  • Fires burning at the same time as this one (a week before or after) are left out: they share the same spell of weather and do not count as a precedent.
  • They are sorted by similarity, and the outlines of the first five are drawn.

How we calculate it

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 28 Dec 2023
After · 22 Jan 2024

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 15 January 2024 the air beside the fire reached 75 µg/m³ of PM2.5. That day averaged 64: 4.2 times the WHO daily guideline (15).

PM2.5 peak75 µg/m³
Days over the guideline16 days
PM10324 µg/m³
Optical depth0.59
2 Jan6 Jan10 Jan14 Jan
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 40Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Burkina Faso

Frequently asked questions

How long did the Niangoloko fire last?
According to the heat detections seen by satellite inside the perimeter, it burned from 4 January 2024 to 15 January 2024 (12 days). The perimeter dates it from 4 January 2024 to 14 January 2024.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 1,418 hectares (14.2 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Niangoloko (1,427 ha, 0.5 %).
What was the weather like?
During the fire the temperature reached 37.0 °C, humidity dropped to 12 % and gusts hit 32 km/h. The fire danger index (FWI) reached 47, class Very high.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Burkina Faso (OCHA COD-AB). It is not an official report.
How did the fires that started in similar weather in this area end?
Fires less than 250 km away that started since 2016 with a similar FWI, humidity and dry spell: 38. Their median duration was 5 days and their median area 1,726 ha; 100 % went past 1,000 ha. In none of them did 1 mm fall in the ten days after the end: they all went out without rain.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

History of this page · 1 Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.
  1. Last day with fire: 14 January 2024 → 15 January 2024.

RSS Changes to this page With cross-checks and a citable version

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates adjusted with the VIIRS detections inside the perimeter, which said 4 January 2024 to 14 January 2024. 40 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from OCHA COD-AB (Institut Geographique Burkina (IGB)) (Creative Commons Attribution for Intergovernmental Organisations (CC BY-IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.