Skip to content
worldfires
BF · Burkina Faso · –

Niangoloko fire, 14 December 2016 Niangoloko

Out · last detection 30 Dec 2016, 02:02 UTC

The fire started on 14 December 2016 in Niangoloko, Burkina Faso, and satellites saw it burning for 17 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 5,550 hectares from heat detections, spread across a single municipality.

It is the 4th largest in Tannounyan since 2016 (of 113 with a page). Number 3 in Burkina Faso in 2016, of 144.

Burnt area
5,550ha
GWIS perimeter (Copernicus)
Duration
17days
14 Dec 2016 – 30 Dec 2016
Municipalities hit
1
communes
Started on
14 Dec
2016
Heat detections
199
in a single hotspot: 63 MW
Danger at start
50
Extreme · FWI index
Average daily power
68MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 14 Dec30 Dec
30 Dec 2016

How it evolved, day by day

14 Dec 2016 · 8 MW · 2 15 Dec 2016 · 67 MW · 7 17 Dec 2016 · 88 MW · 22 19 Dec 2016 · 28 MW · 9 20 Dec 2016 · 71 MW · 8 21 Dec 2016 · 100 MW · 19 22 Dec 2016 · 23 MW · 7 23 Dec 2016 · 278 MW · 34 24 Dec 2016 · 108 MW · 35 25 Dec 2016 · 49 MW · 19 26 Dec 2016 · 74 MW · 21 27 Dec 2016 · 24 MW · 4 29 Dec 2016 · 23 MW · 5 30 Dec 2016 · 7 MW · 7
14 Dec 19 Dec 23 Dec 29 Dec

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

36°high
38km/h · peak gust
11%lowest humidity

It had gone 39 days without rain (1 mm or more) when it started.

This area had burned before

No earlier perimeters overlap this fire since 2016, when the satellite record begins.

How big is it?

10 km
It burned the equivalent of 3.5% of the area of London (56 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Niangoloko where it started
    5,583 ha reached on 14 Dec
    2.0 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2015
Built-up area< 0.1 ha
Residents< 20

Inside the perimeter there was no noticeable built-up land and almost nobody lived there (GHSL 2015, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Started with Very dry air: 56 % of the area in Burkina Faso

Day High Min. humidity Peak gust Rain Danger (FWI)
14 Dec 34.8 °C 11 % 38 km/h 0.0 mm Extreme 50
15 Dec 34.6 °C 12 % 30 km/h 0.0 mm Very high 47
16 Dec 33.9 °C 14 % 28 km/h 0.0 mm Very high 47
17 Dec 34.3 °C 15 % 27 km/h 0.0 mm Very high 45
18 Dec 32.3 °C 20 % 22 km/h 0.0 mm Very high 44
19 Dec 34.5 °C 17 % 32 km/h 0.0 mm Very high 44
20 Dec 34.9 °C 15 % 30 km/h 0.0 mm Very high 45
21 Dec 35.1 °C 16 % 26 km/h 0.0 mm Very high 43
22 Dec 34.8 °C 14 % 27 km/h 0.0 mm Very high 45
23 Dec 35.7 °C 11 % 33 km/h 0.0 mm Extreme 50
24 Dec 35.6 °C 12 % 28 km/h 0.0 mm Very high 48
25 Dec 33.7 °C 18 % 27 km/h 0.0 mm Very high 46
26 Dec 32.9 °C 15 % 33 km/h 0.0 mm Extreme 50
27 Dec 33.4 °C 14 % 32 km/h 0.0 mm Extreme 51
28 Dec 32.6 °C 15 % 33 km/h 0.0 mm Very high 50
29 Dec 33.0 °C 17 % 32 km/h 0.0 mm Very high 49
30 Dec 33.4 °C 15 % 28 km/h 0.0 mm Very high 47
31 Dec after 34.2 °C 16 % 32 km/h 0.0 mm Very high 49
1 Jan after 34.2 °C 17 % 30 km/h 0.0 mm Very high 49
2 Jan after 33.2 °C 17 % 31 km/h 0.0 mm Very high 49
3 Jan after 33.6 °C 18 % 31 km/h 0.0 mm Very high 49
4 Jan after 33.6 °C 14 % 31 km/h 0.0 mm Very high 49
5 Jan after 34.1 °C 13 % 31 km/h 0.0 mm Very high 49
6 Jan after 34.7 °C 14 % 28 km/h 0.0 mm Very high 47
7 Jan after 35.1 °C 15 % 29 km/h 0.0 mm Very high 47
8 Jan after 35.2 °C 14 % 30 km/h 0.0 mm Very high 49
9 Jan after 35.3 °C 15 % 32 km/h 0.0 mm Extreme 52

Its twins: fires that started in the same weather

It started with an FWI of 50.2, a minimum humidity of 11% and 39 days without rain. Fires in the area that started in weather like this since 2016: 60.

FWI at the start 50.2
Minimum humidity 11 %
Days without rain 39
this fire chosen twins rest of the area
Almost identicalSimilar

Outlines of the closest twins

Parc national de la Comoé fire, January 2021
1,935 ha 4 days FWI 50.7 Min. humidity 11 % 158 km away, in 2021

First rain (1 mm or more) after it ended: none in the following ten days.

What happened to them

6 days
median duration
1,479 ha
median area
100 %
went past 1,000 ha
2.9 mm
rain at the end (median; 2 of 60 had it)

It was 3.8 times larger than the median of its twins and lasted 17 days, against 6 days.

Only 1 of its 60 twins burned more. The weather on the first day does not explain everything: the wind in the following days, the fuel and the firefighting also count. In 58 of 60, not even 1 mm fell in the ten days after the end: they went out without rain. In the rest, the first rainy day brought a median of 2.9 mm.

This is a bank of analogues: it shows what usually happens, not what will happen. With fewer than 15 twins we give no figures. How we calculate it

How it ended

—first rain
—no rain in ten days
38km/h · max. gust

It was considered over on 30 Dec, and not even 1 mm fell in the following ten days: it went out without rain. Twins with rain when they ended: 2 of 60, with a median of 2.9 mm.

Weather on this page: Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

How a twin is chosen

  • Same area: fires that have already ended, less than 250 km from this one, since 2016.
  • Same start: we compare the FWI on the first day, the minimum humidity that day and the run of days without rain before it. The slider sets how much they may differ.
  • Only pages with final weather data (ERA5 reanalysis) calculated in the same way as this fire’s; agricultural and grass burns and pages with data under review are left out.
  • Fires burning at the same time as this one (a week before or after) are left out: they share the same spell of weather and do not count as a precedent.
  • They are sorted by similarity, and the outlines of the first five are drawn.

How we calculate it

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 7 Dec 2016
After · 6 Jan 2017

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

Detections table · 199Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Burkina Faso

Frequently asked questions

How long did the Niangoloko fire last?
According to the heat detections seen by satellite inside the perimeter, it burned from 14 December 2016 to 30 December 2016 (17 days). The perimeter dates it from 20 December 2016 to 26 December 2016.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 5,550 hectares (55.5 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Niangoloko (5,583 ha, 2.0 %).
What was the weather like?
During the fire the temperature reached 35.7 °C, humidity dropped to 11 % and gusts hit 38 km/h. The fire danger index (FWI) reached 51, class Extreme.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Burkina Faso (OCHA COD-AB). It is not an official report.
How did the fires that started in similar weather in this area end?
Fires less than 250 km away that started since 2016 with a similar FWI, humidity and dry spell: 60. Their median duration was 6 days and their median area 1,479 ha; 100 % went past 1,000 ha. Only 1 of its 60 twins burned more. The weather on the first day does not explain everything: the wind in the following days, the fuel and the firefighting also count. In 58 of 60, not even 1 mm fell in the ten days after the end: they went out without rain. In the rest, the first rainy day brought a median of 2.9 mm.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

History of this page · 2 Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.
  1. Last day with fire: 26 December 2016 → 30 December 2016.
  2. Start date: 20 December 2016 → 14 December 2016.

RSS Changes to this page With cross-checks and a citable version

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates adjusted with the VIIRS detections inside the perimeter, which said 20 December 2016 to 26 December 2016. 199 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2015, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from OCHA COD-AB (Institut Geographique Burkina (IGB)) (Creative Commons Attribution for Intergovernmental Organisations (CC BY-IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.