Skip to content
worldfires
BW · Botswana · –

Ngwaketse North fire, 29 July 2026 Ngwaketse North

Out · last detection

The fire started on in Ngwaketse North, Botswana, and satellites saw it burning for 9 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 12,884 hectares from heat detections, spread across a single municipality.

Number 36 in Botswana in 2026, of 329.

GWIS near-real-time perimeter, from the layer that changed in August 2025: this fire is not compared with fires from earlier years, because since then the GWIS layer gives more and larger perimeters.

Burnt area
12,884ha
GWIS perimeter (Copernicus)
Duration
9days
29 Jul 2026 – 6 Aug 2026
Municipalities hit
1
subdistricts
Started on
29 Jul
2026
Heat detections
293
in a single hotspot: 164 MW
Danger at start
62
Extreme · FWI index
Average daily power
689MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 29 Jul6 Aug
6 Aug 2026

How it evolved, day by day

29 Jul 2026 · 20 MW · 3 30 Jul 2026 · 1,154 MW · 65 31 Jul 2026 · 243 MW · 47 1 Aug 2026 · 376 MW · 32 2 Aug 2026 · 59 MW · 5 3 Aug 2026 · 180 MW · 31 4 Aug 2026 · 4,125 MW · 102 5 Aug 2026 · 12 MW · 2 6 Aug 2026 · 30 MW · 6
29 Jul 31 Jul 2 Aug 4 Aug 6 Aug

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

Fire front film How it spread from one satellite pass to the next (18 passes) and with what wind. Watch the film

The weather it burned in

28°high
41km/h · peak gust
7%lowest humidity

It had gone 38 days without rain (1 mm or more) when it started.

This area had burned before

41% of the perimeter overlaps earlier fires recorded since 2016: 2,310 ha in 2021, 2,419 ha in 2022, 163 ha in 2023, 1,329 ha in 2025. Part of it burned more than once, so the yearly figures add up to more than the 5,335 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 8.1% of the area of London (129 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Ngwaketse North where it started
    12,956 ha
    0.9 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area< 0.1 ha
Residents< 20

Inside the perimeter there was no noticeable built-up land and almost nobody lived there (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Started with Extreme FWI: 80 % of the area in Botswana

Day High Min. humidity Peak gust Rain Danger (FWI)
29 Jul 26.9 °C 15 % 41 km/h 0.0 mm Extreme 62
30 Jul 27.1 °C 9 % 31 km/h 0.0 mm Extreme 57
31 Jul 24.8 °C 7 % 22 km/h 0.0 mm Very high 49
1 Aug 24.7 °C 24 % 41 km/h 0.0 mm Extreme 59
2 Aug 24.6 °C 22 % 28 km/h 0.0 mm Very high 45
3 Aug 24.9 °C 13 % 24 km/h 0.0 mm Very high 45
4 Aug 25.5 °C 8 % 41 km/h 0.0 mm Very extreme 75
5 Aug 27.0 °C 11 % 35 km/h 0.0 mm Very extreme 71
6 Aug 28.4 °C 9 % 29 km/h 0.0 mm Extreme 60
7 Aug after 28.1 °C 10 % 40 km/h 0.0 mm Very extreme 83
8 Aug after 26.2 °C 17 % 40 km/h 0.0 mm Very extreme 75
9 Aug after 27.5 °C 14 % 48 km/h 0.0 mm Very extreme 92
10 Aug after 15.4 °C 29 % 56 km/h 0.0 mm Extreme 63
11 Aug after 17.3 °C 27 % 37 km/h 0.0 mm High 36
12 Aug after 19.8 °C 35 % 54 km/h 0.1 mm Extreme 64
13 Aug after 21.9 °C 38 % 50 km/h 0.0 mm Extreme 51
14 Aug after 23.6 °C 27 % 39 km/h 0.0 mm Very high 45
15 Aug after 23.9 °C 20 % 28 km/h 0.0 mm Very high 40
16 Aug after 25.6 °C 18 % 30 km/h 0.0 mm Extreme 52

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 22 Jul 2026
After · 13 Aug 2026

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 28 July 2026 the air beside the fire reached 39 µg/m³ of PM2.5. That day averaged 21: 1.4 times the WHO daily guideline (15).

PM2.5 peak39 µg/m³
Days over the guideline5 days
PM1042 µg/m³
Optical depth0.38
27 Jul30 Jul2 Aug5 Aug8 Aug
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 293Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Botswana

Frequently asked questions

How long did the Ngwaketse North fire last?
GWIS (Copernicus) dates it between 29 July 2026 and 6 August 2026: 9 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 12,884 hectares (128.8 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Ngwaketse North (12,956 ha, 0.9 %).
What was the weather like?
During the fire the temperature reached 28.4 °C, humidity dropped to 7 % and gusts hit 41 km/h. The fire danger index (FWI) reached 75, class Very extreme.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Botswana (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

History of this page Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery; 2 polygons grouped in this page.
  • Dates from the perimeter: the VIIRS detections inside it did not change them. 293 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Public Domain). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.