Skip to content
worldfires
VE · Venezuela · →

Muñoz fire, 22 March 2023 Muñoz

Out · last detection 25 Mar 2023, 18:38 UTC

The fire started on 22 March 2023 in Muñoz, Venezuela, and satellites saw it burning for 4 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 1,671 hectares from heat detections, spread across a single municipality.

It is the 734th largest in Apure since 2016 (of 919 with a page). Number 146 in Venezuela in 2023, of 193.

Burnt area
1,671ha
GWIS perimeter (Copernicus)
Duration
4days
22 Mar 2023 – 25 Mar 2023
Municipalities hit
1
municipalities
Started on
22 Mar
2023
Heat detections
56
in a single hotspot: 118 MW
Danger at start
35
High · FWI index
Energy released
761MW
sum of detected power

Where it burned

25 Mar 2023
HOTSPOTS BY DAY 22 Mar25 Mar

How it evolved, day by day

22232425

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

36°high
43km/h · peak gust
28%lowest humidity

It had gone 10 days without rain (1 mm or more) when it started.

This area had burned before

69% of the perimeter overlaps earlier fires recorded since 2016: 812 ha in 2018, 980 ha in 2020. Part of it burned more than once, so the yearly figures add up to more than the 1,150 ha that had burned before.

What happened to each town

  1. Muñoz 27,542 inhabitants where it started
    1,681 ha reached on 22 Mar
    0.2 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance is from the town centre to the nearest fire: staying a kilometre away does not mean it reached the houses.

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
22 Mar 35.0 °C 32 % 43 km/h 0.0 mm High 35
23 Mar 36.2 °C 28 % 42 km/h 0.0 mm High 35
24 Mar 36.1 °C 30 % 42 km/h 0.0 mm High 36
25 Mar 35.3 °C 34 % 43 km/h 0.0 mm High 35
26 Mar after 33.2 °C 46 % 38 km/h 0.0 mm High 26
27 Mar after 35.3 °C 37 % 41 km/h 0.0 mm High 28
28 Mar after 35.1 °C 33 % 38 km/h 0.0 mm High 30
29 Mar after 34.8 °C 41 % 39 km/h 0.0 mm High 31
30 Mar after 35.8 °C 37 % 38 km/h 0.0 mm High 32
31 Mar after 35.3 °C 42 % 41 km/h 0.2 mm High 32
1 Apr after 34.8 °C 41 % 46 km/h 0.8 mm High 29
2 Apr after 35.8 °C 35 % 35 km/h 0.1 mm High 29
3 Apr after 37.0 °C 34 % 36 km/h 0.0 mm High 31
4 Apr after 36.9 °C 32 % 40 km/h 0.0 mm High 34

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 15 Mar 2023
After · 1 Apr 2023

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 27 March 2023 the air beside the fire reached 60 µg/m³ of PM2.5. That day averaged 31: 2.1 times the WHO daily guideline (15).

PM2.5 peak60 µg/m³
Days over the guideline9 days
PM1087 µg/m³
Optical depth0.76
202122232425262728
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 56Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Venezuela ›

Frequently asked questions

How long did the Muñoz fire last?
GWIS (Copernicus) dates it between 22 March 2023 and 25 March 2023: 4 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 1,671 hectares (16.7 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Muñoz (1,681 ha, 0.2 %).
What was the weather like?
During the fire the temperature reached 36.2 °C, humidity dropped to 28 % and gusts hit 43 km/h. The fire danger index (FWI) reached 36, class High.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Venezuela (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Emergency number: 911

Satellite cross-check

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy. This is not an emergency service: if there is a fire now, call 911.

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Open Data Commons Open Database License 1.0). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.