Skip to content
worldfires
MZ · Mozambique · →

Mavago fire, August 2025 Mavago

Out · last detection 24 Aug 2025, 21:57 UTC

The fire started on 14 August 2025 in Mavago, Mozambique, and satellites saw it burning for 11 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 6,710 hectares from heat detections, spread across a single municipality.

It is the 122th largest in Niassa since 2016 (of 577 with a page). Number 83 in Mozambique in 2025, of 313.

Compare with…
Burnt area
6,710ha
GWIS perimeter (Copernicus)
Duration
11days
14 Aug 2025 – 24 Aug 2025
Municipalities hit
1
districts
Started on
14 Aug
2025
Heat detections
314
in a single hotspot: 54 MW
Danger at start
30
High · FWI index
Average daily power
158MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 14 Aug24 Aug
24 Aug 2025

How it evolved, day by day

14 Aug 2025 · 83 MW · 11 15 Aug 2025 · 16 MW · 9 16 Aug 2025 · 111 MW · 15 17 Aug 2025 · 173 MW · 15 18 Aug 2025 · 46 MW · 20 19 Aug 2025 · 246 MW · 55 20 Aug 2025 · 190 MW · 36 21 Aug 2025 · 206 MW · 68 22 Aug 2025 · 549 MW · 52 23 Aug 2025 · 99 MW · 21 24 Aug 2025 · 24 MW · 3
14 Aug 16 Aug 18 Aug 20 Aug 22 Aug 24 Aug

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

30°high
34km/h · peak gust
22%lowest humidity

It had gone more than two months without rain (1 mm or more) when it started.

This area had burned before

92% of the perimeter overlaps earlier fires recorded since 2016: 3,073 ha in 2016, 2,304 ha in 2017, 941 ha in 2018, 107 ha in 2019, 3,034 ha in 2020, 4,369 ha in 2021, 508 ha in 2022, 2,932 ha in 2023, 24 ha in 2024. Part of it burned more than once, so the yearly figures add up to more than the 6,198 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 4.2% of the area of London (67 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Mavago where it started
    6,745 ha reached on 13 Aug
    0.7 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area< 0.1 ha
Residents< 20

Inside the perimeter there was no noticeable built-up land and almost nobody lived there (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
14 Aug 27.7 °C 37 % 30 km/h 0.2 mm High 30
15 Aug 26.7 °C 41 % 32 km/h 0.7 mm High 23
16 Aug 28.5 °C 37 % 34 km/h 0.2 mm High 28
17 Aug 27.2 °C 34 % 31 km/h 0.0 mm High 27
18 Aug 27.6 °C 34 % 30 km/h 0.0 mm High 27
19 Aug 28.2 °C 34 % 30 km/h 0.1 mm High 28
20 Aug 27.7 °C 37 % 28 km/h 0.3 mm High 27
21 Aug 27.5 °C 38 % 32 km/h 0.2 mm High 28
22 Aug 29.2 °C 30 % 30 km/h 0.0 mm High 30
23 Aug 29.8 °C 22 % 31 km/h 0.0 mm High 34
24 Aug 30.4 °C 24 % 30 km/h 0.0 mm High 35
25 Aug after 30.8 °C 31 % 28 km/h 0.0 mm High 36
26 Aug after 30.3 °C 25 % 29 km/h 0.0 mm High 37
27 Aug after 31.4 °C 18 % 38 km/h 0.0 mm Very high 42
28 Aug after 31.3 °C 23 % 29 km/h 0.0 mm Very high 38
29 Aug after 30.9 °C 23 % 36 km/h 0.0 mm Very high 42
30 Aug after 30.8 °C 24 % 36 km/h 0.0 mm Very high 42
31 Aug after 31.0 °C 23 % 32 km/h 0.0 mm Very high 39
1 Sept after 31.3 °C 26 % 28 km/h 0.0 mm Very high 39
2 Sept after 30.6 °C 30 % 36 km/h 0.1 mm Very high 39
3 Sept after 29.5 °C 31 % 30 km/h 0.5 mm High 35

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 7 Aug 2025
After · 31 Aug 2025

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 27 August 2025 the air beside the fire reached 61 µg/m³ of PM2.5. That day averaged 35: 2.3 times the WHO daily guideline (15).

PM2.5 peak61 µg/m³
Days over the guideline13 days
PM1063 µg/m³
Optical depth0.72
12131415161718192021222324252627
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 314Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Mozambique ›

Frequently asked questions

How long did the Mavago fire last?
GWIS (Copernicus) dates it between 14 August 2025 and 24 August 2025: 11 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 6,710 hectares (67.1 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Mavago (6,745 ha, 0.7 %).
What was the weather like?
During the fire the temperature reached 30.4 °C, humidity dropped to 22 % and gusts hit 34 km/h. The fire danger index (FWI) reached 35, class High.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Mozambique (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

History of this page Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.

No changes since 24 October 2026.

RSS Changes to this page

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates from the perimeter: the VIIRS detections inside it did not change them. 314 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology ›

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.