Skip to content
worldfires
MZ · Mozambique · →

Matutuíne fire, August 2017 Matutuíne

Out · last detection 24 Aug 2017, 12:12 UTC

The fire started on 22 August 2017 in Matutuíne, Mozambique, and satellites saw it burning for 3 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 3,347 hectares from heat detections, spread across a single municipality.

It is the 10th largest in Maputo since 2016 (of 16 with a page). Number 150 in Mozambique in 2017, of 196.

Burnt area
3,347ha
GWIS perimeter (Copernicus)
Duration
3days
22 Aug 2017 – 24 Aug 2017
Municipalities hit
1
districts
Started on
22 Aug
2017
Heat detections
110
in a single hotspot: 80 MW
Danger at start
48
Very high · FWI index
Energy released
1.6GW
sum of detected power

Where it burned

24 Aug 2017
HOTSPOTS BY DAY 22 Aug24 Aug

How it evolved, day by day

222324

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

31°high
58km/h · peak gust
11%lowest humidity

It had gone 3 days without rain (1 mm or more) when it started. Rain came after the fire: 5.0 mm on 27 Aug.

This area had burned before

No earlier perimeters overlap this fire since 2016, when the satellite record begins.

What happened to each town

  1. Matutuíne where it started
    3,354 ha reached on 19 Aug
    0.6 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance is from the town centre to the nearest fire: staying a kilometre away does not mean it reached the houses.

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
22 Aug 30.6 °C 24 % 58 km/h 0.0 mm Very high 48
23 Aug 25.3 °C 22 % 53 km/h 0.0 mm Very high 42
24 Aug 30.3 °C 11 % 50 km/h 0.0 mm Extreme 54
25 Aug after 24.4 °C 45 % 35 km/h 0.0 mm High 32
26 Aug after 22.6 °C 52 % 32 km/h 0.0 mm High 23
27 Aug after 25.5 °C 50 % 38 km/h 5.0 mm Low 6

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 15 Aug 2017
After · 31 Aug 2017

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

Detections table · 110Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Mozambique ›

Frequently asked questions

How long did the Matutuíne fire last?
GWIS (Copernicus) dates it between 22 August 2017 and 24 August 2017: 3 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 3,347 hectares (33.5 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Matutuíne (3,354 ha, 0.6 %).
What was the weather like?
During the fire the temperature reached 30.6 °C, humidity dropped to 11 % and gusts hit 58 km/h. The fire danger index (FWI) reached 54, class Extreme.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Mozambique (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.