Skip to content
worldfires
SY · Syria · →

Madiq Castle fire, July 2026 Madiq Castle

Out · last detection 30 Jul 2026, 11:38 UTC

The fire started on 30 July 2026 in Madiq Castle, Syria, and satellites saw it burning for 1 day. Copernicus mapped a burnt perimeter of 165 hectares from satellite imagery, spread across a single municipality.

It is the 27th largest in Hama since 2016 (of 37 with a page). The largest in Syria in 2026, of 3.

The power measured by the satellite is low (8.0 MW in the strongest hotspot), more typical of grass or stubble burning, or a slow surface fire, than of a large crown fire.

Burnt area
165ha
Copernicus perimeter
Duration
1day
30 Jul 2026 – 30 Jul 2026
Municipalities hit
1
subdistricts
Started on
30 Jul
2026
Heat detections
7
in a single hotspot: 8 MW
Danger at start
35
High · FWI index
Energy released
47MW
sum of detected power

Where it burned

HOTSPOTS BY DAY 30 Jul30 Jul

How it evolved, day by day

30

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

35°high
34km/h · peak gust
38%lowest humidity

It had gone more than two months without rain (1 mm or more) when it started.

This area had burned before

15% of the perimeter overlaps earlier fires recorded since 2016: 24 ha in 2024.

What happened to each town

  1. Madiq Castle where it started
    166 ha reached on 30 Jul
    0.6 %

Burnt area inside each municipality, from crossing the official perimeter with administrative boundaries. The distance is from the town centre to the nearest fire: staying a kilometre away does not mean it reached the houses.

What burned

  • Other natural land99 %
  • Agricultural areas1.2 %

Land cover inside the perimeter as reported by Copernicus EFFIS (outside the Corine Land Cover area).

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
30 Jul 35.3 °C 38 % 34 km/h 0.0 mm High 35
31 Jul after 36.2 °C 32 % 32 km/h 0.0 mm High 34
1 Aug after 37.4 °C 22 % 32 km/h 0.0 mm Very high 40
2 Aug after 36.9 °C 22 % 41 km/h 0.0 mm Very high 41
3 Aug after 35.8 °C 22 % 35 km/h 0.0 mm Very high 41
4 Aug after 35.3 °C 31 % 34 km/h 0.0 mm Very high 39
5 Aug after 35.8 °C 24 % 33 km/h 0.0 mm Very high 40
6 Aug after 33.5 °C 36 % 36 km/h 0.0 mm High 37
7 Aug after 33.3 °C 42 % 37 km/h 0.0 mm High 34
8 Aug after 33.4 °C 42 % 38 km/h 0.0 mm High 34
9 Aug after 34.8 °C 30 % 37 km/h 0.0 mm High 36

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 23 Jul 2026
After · 6 Aug 2026

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 2 August 2026 the air beside the fire reached 15 µg/m³ of PM2.5, but no daily average passed the WHO guideline (15).

PM2.5 peak15 µg/m³
Days over the guideline0 days
PM1025 µg/m³
Optical depth0.24
2829303112
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 7Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Syria ›

Frequently asked questions

How long did the Madiq Castle fire last?
Copernicus dates it between 30 July 2026 and 30 July 2026: 1 day between the first and last image with fire.
How much area did it burn?
The perimeter Copernicus measured from satellite imagery is 165 hectares (1.6 km²). Official national figures may differ.
Which municipalities burned?
The fire only entered Madiq Castle (166 ha, 0.6 %).
What was the weather like?
During the fire the temperature reached 35.3 °C, humidity dropped to 38 % and gusts hit 34 km/h. The fire danger index (FWI) reached 35, class High.
Where does this data come from?
From the EFFIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Syria (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

Where this data comes from

The perimeter and land cover come from the Copernicus European Forest Fire Information System (EFFIS), measured on MODIS and Sentinel-2 imagery and published under CC BY 4.0. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM3 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ slightly from each country’s official figure.