Skip to content
worldfires
GN · Guinea · →

Gnaléah fire, 8 January 2026 Gnaléah

Out · last detection 21 Jan 2026, 14:10 UTC

The fire started on 8 January 2026 in Gnaléah, Guinea, and satellites saw it burning for 14 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 2,972 hectares from heat detections, spread across a single municipality.

It is the 79th largest in Faranah since 2016 (of 208 with a page). Number 104 in Guinea in 2026, of 269.

The power measured by the satellite is low (24.9 MW in the strongest hotspot), more typical of grass or stubble burning, or a slow surface fire, than of a large crown fire.

Compare with…

Suggestions: Douako · 2026

Burnt area
2,972ha
GWIS perimeter (Copernicus)
Duration
14days
8 Jan 2026 – 21 Jan 2026
Municipalities hit
1
sub-prefectures
Started on
8 Jan
2026
Heat detections
61
in a single hotspot: 25 MW
Danger at start
24
High · FWI index
Average daily power
32MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 8 Jan21 Jan
21 Jan 2026

How it evolved, day by day

8 Jan 2026 · 1 MW · 1 9 Jan 2026 · 59 MW · 6 10 Jan 2026 · 6 MW · 1 11 Jan 2026 · 118 MW · 21 12 Jan 2026 · 6 MW · 1 13 Jan 2026 · 2 MW · 1 14 Jan 2026 · 34 MW · 3 15 Jan 2026 · 9 MW · 2 16 Jan 2026 · 10 MW · 1 17 Jan 2026 · 20 MW · 2 18 Jan 2026 · 16 MW · 4 19 Jan 2026 · 113 MW · 9 20 Jan 2026 · 6 MW · 3 21 Jan 2026 · 55 MW · 6
8 Jan 10 Jan 11 Jan 12 Jan 14 Jan 16 Jan 18 Jan 20 Jan

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

35°high
40km/h · peak gust
18%lowest humidity

It had gone one day without rain (1 mm or more) when it started.

This area had burned before

79% of the perimeter overlaps earlier fires recorded since 2016: 1,000 ha in 2017, 51 ha in 2018, 1,499 ha in 2019, 1,200 ha in 2020, 27 ha in 2022, 290 ha in 2024. Part of it burned more than once, so the yearly figures add up to more than the 2,340 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 1.9% of the area of London (30 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Gnaléah where it started
    2,990 ha reached on 8 Jan
    2.8 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area0.70 ha
Residents≈ 150

Inside the perimeter there were about 0.70 hectares of built-up land and about 150 residents (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
8 Jan 29.9 °C 33 % 40 km/h 0.0 mm High 24
9 Jan 32.6 °C 27 % 35 km/h 0.0 mm High 26
10 Jan 32.6 °C 24 % 31 km/h 0.0 mm High 27
11 Jan 34.4 °C 18 % 29 km/h 0.0 mm High 31
12 Jan 34.1 °C 20 % 27 km/h 0.0 mm High 31
13 Jan 34.1 °C 21 % 19 km/h 0.0 mm High 30
14 Jan 34.2 °C 23 % 20 km/h 0.0 mm High 31
15 Jan 34.6 °C 25 % 21 km/h 0.0 mm High 33
16 Jan 34.9 °C 20 % 32 km/h 0.0 mm High 35
17 Jan 34.9 °C 20 % 27 km/h 0.0 mm High 33
18 Jan 34.4 °C 27 % 21 km/h 0.0 mm High 32
19 Jan 34.7 °C 24 % 20 km/h 0.0 mm High 32
20 Jan 32.4 °C 23 % 23 km/h 0.0 mm High 32
21 Jan 32.6 °C 22 % 29 km/h 0.0 mm High 35
22 Jan after 31.7 °C 22 % 30 km/h 0.0 mm High 36
23 Jan after 32.8 °C 20 % 31 km/h 0.0 mm High 36
24 Jan after 33.7 °C 16 % 31 km/h 0.0 mm High 37
25 Jan after 32.7 °C 17 % 35 km/h 0.0 mm Very high 41
26 Jan after 33.7 °C 18 % 30 km/h 0.0 mm Very high 40
27 Jan after 34.5 °C 15 % 29 km/h 0.0 mm Very high 39
28 Jan after 34.5 °C 13 % 24 km/h 0.0 mm Very high 38
29 Jan after 34.9 °C 12 % 22 km/h 0.0 mm Very high 40
30 Jan after 35.6 °C 15 % 23 km/h 0.0 mm Very high 40
31 Jan after 36.0 °C 16 % 22 km/h 0.0 mm Very high 41

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 1 Jan 2026
After · 28 Jan 2026

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 13 January 2026 the air beside the fire reached 112 µg/m³ of PM2.5. That day averaged 80: 5.3 times the WHO daily guideline (15).

PM2.5 peak112 µg/m³
Days over the guideline19 days
PM10207 µg/m³
Optical depth0.72
6789101112131415161718192021222324
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 61Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Guinea ›

Frequently asked questions

How long did the Gnaléah fire last?
GWIS (Copernicus) dates it between 8 January 2026 and 21 January 2026: 14 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 2,972 hectares (29.7 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Gnaléah (2,990 ha, 2.8 %).
What was the weather like?
During the fire the temperature reached 34.9 °C, humidity dropped to 18 % and gusts hit 40 km/h. The fire danger index (FWI) reached 35, class High.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Guinea (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

History of this page Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.

No changes since 24 October 2026.

RSS Changes to this page

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates from the perimeter: the VIIRS detections inside it did not change them. 61 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology ›

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM3 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.