Skip to content
worldfires
GN · Guinea · →

Douako fire, 13 February 2026 Douako, Tiro, Banian

Out · last detection 20 Feb 2026, 14:48 UTC

The fire started on 13 February 2026 in Douako, Guinea, and satellites saw it burning for 8 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 7,581 hectares from heat detections, spread across 3 municipalities.

It is the 22th largest in Kankan since 2016 (of 388 with a page). Number 13 in Guinea in 2026, of 269.

Compare with…
Burnt area
7,581ha
GWIS perimeter (Copernicus)
Duration
8days
13 Feb 2026 – 20 Feb 2026
Municipalities hit
3
sub-prefectures
Started on
13 Feb
2026
Heat detections
150
in a single hotspot: 57 MW
Danger at start
46
Very high · FWI index
Average daily power
82MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 13 Feb20 Feb
20 Feb 2026

How it evolved, day by day

13 Feb 2026 · 112 MW · 9 14 Feb 2026 · 140 MW · 22 15 Feb 2026 · 56 MW · 13 16 Feb 2026 · 4 MW · 3 17 Feb 2026 · 230 MW · 43 18 Feb 2026 · 62 MW · 17 19 Feb 2026 · 46 MW · 9 20 Feb 2026 · 4 MW · 2
13 Feb 15 Feb 17 Feb 19 Feb

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

38°high
38km/h · peak gust
4%lowest humidity

It had gone 36 days without rain (1 mm or more) when it started.

This area had burned before

92% of the perimeter overlaps earlier fires recorded since 2016: 179 ha in 2016, 2,935 ha in 2017, 2,332 ha in 2019, 299 ha in 2020, 1,035 ha in 2021, 3,886 ha in 2022, 1,963 ha in 2023, 3,374 ha in 2024, 3,043 ha in 2025. Part of it burned more than once, so the yearly figures add up to more than the 6,990 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 4.8% of the area of London (76 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Douako where it started
    7,095 ha reached on 11 Feb
    2.5 %
  2. 515 ha reached on 19 Feb
    0.9 %
  3. 17 ha
    0.0 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area2.1 ha
Residents≈ 450

Inside the perimeter there were about 2.1 hectares of built-up land and about 450 residents (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
13 Feb 37.5 °C 9 % 26 km/h 0.0 mm Very high 46
14 Feb 36.1 °C 12 % 30 km/h 0.0 mm Extreme 50
15 Feb 37.1 °C 14 % 28 km/h 0.0 mm Very high 49
16 Feb 36.4 °C 10 % 38 km/h 0.0 mm Extreme 51
17 Feb 36.3 °C 9 % 33 km/h 0.0 mm Very high 50
18 Feb 36.1 °C 7 % 25 km/h 0.0 mm Very high 49
19 Feb 36.4 °C 4 % 31 km/h 0.0 mm Extreme 51
20 Feb 37.6 °C 5 % 31 km/h 0.0 mm Extreme 51
21 Feb after 37.3 °C 10 % 29 km/h 0.0 mm Extreme 54
22 Feb after 37.7 °C 4 % 33 km/h 0.0 mm Extreme 56
23 Feb after 37.1 °C 6 % 26 km/h 0.0 mm Extreme 51
24 Feb after 37.0 °C 5 % 30 km/h 0.0 mm Extreme 54
25 Feb after 37.1 °C 11 % 23 km/h 0.0 mm Extreme 56
26 Feb after 35.3 °C 24 % 28 km/h 0.0 mm Very high 45
27 Feb after 34.3 °C 31 % 31 km/h 0.0 mm Very high 42
28 Feb after 36.0 °C 21 % 27 km/h 0.0 mm Very high 39
1 Mar after 34.5 °C 12 % 24 km/h 0.0 mm Very high 42
2 Mar after 32.1 °C 29 % 28 km/h 0.0 mm High 36

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 6 Feb 2026
After · 27 Feb 2026

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 20 February 2026 the air beside the fire reached 175 µg/m³ of PM2.5. That day averaged 107: 7.1 times the WHO daily guideline (15).

PM2.5 peak175 µg/m³
Days over the guideline13 days
PM10285 µg/m³
Optical depth0.81
11121314151617181920212223
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 150Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Guinea ›

Frequently asked questions

How long did the Douako fire last?
GWIS (Copernicus) dates it between 13 February 2026 and 20 February 2026: 8 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 7,581 hectares (75.8 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire entered 3 municipalities: Douako (7,095 ha, 2.5 %); Tiro (515 ha, 0.9 %); Banian (17 ha, 0.0 %).
What was the weather like?
During the fire the temperature reached 37.6 °C, humidity dropped to 4 % and gusts hit 38 km/h. The fire danger index (FWI) reached 51, class Extreme.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Guinea (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

History of this page Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.

No changes since 24 October 2026.

RSS Changes to this page

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates from the perimeter: the VIIRS detections inside it did not change them. 150 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology ›

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM3 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.