Skip to content
worldfires
CN · China · →

Fuyu fire, 10 November 2025 扶余市 · Fuyu, Shuangcheng City

Out · last detection 22 Nov 2025, 18:31 UTC

The fire started on 10 November 2025 in Fuyu, China, and satellites saw it burning for 13 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 3,686 hectares from heat detections, spread across 2 municipalities.

It is the 127th largest in Jilin Province since 2016 (of 825 with a page). Number 116 in China in 2025, of 711.

Compare with…
Burnt area
3,686ha
GWIS perimeter (Copernicus)
Duration
13days
10 Nov 2025 – 22 Nov 2025
Municipalities hit
2
counties
Started on
10 Nov
2025
Heat detections
49
in a single hotspot: 68 MW
Danger at start
7
Low · FWI index
Average daily power
70MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 10 Nov22 Nov
22 Nov 2025

How it evolved, day by day

10 Nov 2025 · 7 MW · 2 16 Nov 2025 · 16 MW · 2 19 Nov 2025 · 283 MW · 31 20 Nov 2025 · 20 MW · 4 21 Nov 2025 · 95 MW · 7 22 Nov 2025 · 2 MW · 3
10 Nov 16 Nov 19 Nov 20 Nov 21 Nov 22 Nov

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

11°high
53km/h · peak gust
18%lowest humidity

It had gone one day without rain (1 mm or more) when it started. Rain came after the fire: 1.0 mm on 27 Nov.

This area had burned before

55% of the perimeter overlaps earlier fires recorded since 2016: 309 ha in 2016, 17 ha in 2017, 381 ha in 2018, 1,042 ha in 2019, 158 ha in 2020, 600 ha in 2021, 476 ha in 2022, 195 ha in 2023. Part of it burned more than once, so the yearly figures add up to more than the 2,040 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 2.3% of the area of London (37 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Fuyu 扶余市 where it started
    3,656 ha reached on 10 Nov
    0.8 %
  2. 31 ha
    0.0 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area25 ha
Residents≈ 250

Inside the perimeter there were about 25 hectares of built-up land and about 250 residents (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
10 Nov 0.4 °C 35 % 33 km/h 0.0 mm Low 7
11 Nov 5.1 °C 29 % 27 km/h 0.0 mm Low 8
12 Nov 11.0 °C 41 % 53 km/h 0.0 mm Moderate 13
13 Nov 4.0 °C 18 % 53 km/h 0.0 mm Moderate 16
14 Nov 3.8 °C 22 % 14 km/h 0.0 mm Low 10
15 Nov 8.9 °C 36 % 41 km/h 0.0 mm Moderate 14
16 Nov 1.6 °C 29 % 50 km/h 0.2 mm Moderate 17
17 Nov -3.4 °C 39 % 46 km/h 0.0 mm Moderate 14
18 Nov -2.6 °C 41 % 29 km/h 0.0 mm Low 9
19 Nov 5.7 °C 31 % 47 km/h 0.0 mm Moderate 14
20 Nov 1.7 °C 31 % 44 km/h 0.0 mm Moderate 12
21 Nov 2.1 °C 35 % 35 km/h 0.0 mm Low 11
22 Nov 9.4 °C 26 % 47 km/h 0.0 mm Moderate 15
23 Nov after 8.2 °C 25 % 35 km/h 0.0 mm Moderate 13
24 Nov after 0.0 °C 49 % 32 km/h 0.4 mm Low 10
25 Nov after -0.9 °C 41 % 17 km/h 0.0 mm Low 8
26 Nov after 0.6 °C 50 % 32 km/h 0.4 mm Low 8
27 Nov after -4.4 °C 45 % 33 km/h 1.0 mm Very low 4

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 3 Nov 2025
After · 29 Nov 2025

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 25 November 2025 the air beside the fire reached 82 µg/m³ of PM2.5. That day averaged 61: 4.1 times the WHO daily guideline (15).

PM2.5 peak82 µg/m³
Days over the guideline8 days
PM1090 µg/m³
Optical depth0.73
141516171819202122232425
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 49Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in China ›

Frequently asked questions

How long did the Fuyu fire last?
According to the heat detections seen by satellite inside the perimeter, it burned from 10 November 2025 to 22 November 2025 (13 days). The perimeter dates it from 16 November 2025 to 22 November 2025.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 3,686 hectares (36.9 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire entered 2 municipalities: Fuyu (3,656 ha, 0.8 %); Shuangcheng City (31 ha, 0.0 %).
What was the weather like?
During the fire the temperature reached 11.0 °C, humidity dropped to 18 % and gusts hit 53 km/h. The fire danger index (FWI) reached 17, class Moderate.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of China (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Emergency number: 119 · Emergency number and official warnings ›

Satellite cross-check

History of this page · 1 Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.
  1. Start date: 16 November 2025 → 10 November 2025.

RSS Changes to this page

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy. This is not an emergency service: if there is a fire now, call 119.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates adjusted with the VIIRS detections inside the perimeter, which said 16 November 2025 to 22 November 2025. 49 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology ›

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM3 (Open Data Commons Open Database License 1.0). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.