Skip to content
worldfires
SN · Senegal · –

Dianké Makan fire, March 2025 Dianké Makan, Missira

Out · last detection

The fire started on in Dianké Makan, Senegal, and satellites saw it burning for 4 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 2,912 hectares from heat detections, spread across 2 municipalities.

It is number 84 by size of the 222 fires with a page that started in Tambacounda since 2016. Number 20 in Senegal in 2025, of 45.

Burnt area
2,912ha
GWIS perimeter (Copernicus)
Duration
4days
15 Mar 2025 – 18 Mar 2025
Municipalities hit
2
districts
Started on
15 Mar
2025
Heat detections
96
in a single hotspot: 38 MW
Danger at start
64
Extreme · FWI index
Average daily power
206MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 15 Mar18 Mar
18 Mar 2025

How it evolved, day by day

16 Mar 2025 · 315 MW · 64 17 Mar 2025 · 262 MW · 26 18 Mar 2025 · 42 MW · 6
16 Mar 17 Mar 18 Mar

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

44°high
34km/h · peak gust
12%lowest humidity

It had gone more than two months without rain (1 mm or more) when it started.

This area had burned before

48% of the perimeter overlaps earlier fires recorded since 2016: 178 ha in 2016, 17 ha in 2017, 37 ha in 2021, 1,312 ha in 2022. Part of it burned more than once, so the yearly figures add up to more than the 1,409 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 1.8% of the area of London (29 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Dianké Makan where it started
    2,726 ha reached on 16 Mar
    0.9 %
  2. 203 ha reached on 16 Mar
    0.0 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area< 0.1 ha
Residents< 20

Inside the perimeter there was no noticeable built-up land and almost nobody lived there (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Started with Extreme FWI: 80 % of the area in Senegal Very dry air: 43 % of the area in Senegal 60 days without rain: 79 % of the area in Senegal

Day High Min. humidity Peak gust Rain Danger (FWI)
15 Mar 43.5 °C 14 % 34 km/h 0.0 mm Extreme 64
16 Mar 41.9 °C 24 % 27 km/h 0.1 mm Very high 49
17 Mar 41.9 °C 18 % 34 km/h 0.0 mm Extreme 56
18 Mar 43.5 °C 12 % 27 km/h 0.0 mm Extreme 52
19 Mar after 41.7 °C 19 % 34 km/h 0.0 mm Very high 47
20 Mar after 41.2 °C 21 % 40 km/h 0.0 mm Extreme 55
21 Mar after 44.0 °C 13 % 27 km/h 0.0 mm Extreme 53
22 Mar after 42.6 °C 20 % 41 km/h 0.0 mm Extreme 63
23 Mar after 40.7 °C 22 % 40 km/h 0.0 mm Extreme 55
24 Mar after 41.5 °C 16 % 29 km/h 0.0 mm Very high 44
25 Mar after 40.7 °C 18 % 27 km/h 0.0 mm Very high 45
26 Mar after 41.9 °C 13 % 30 km/h 0.0 mm Extreme 64
27 Mar after 41.7 °C 13 % 24 km/h 0.0 mm Extreme 56
28 Mar after 41.5 °C 13 % 31 km/h 0.0 mm Extreme 62

Its twins: fires that started in the same weather

It started with an FWI of 64.4, a minimum humidity of 14% and more than two months without rain. Fires in the area that started in weather like this since 2016: 37.

FWI at the start 64.4
Minimum humidity 14 %
Days without rain 60+
this fire chosen twins rest of the area
Almost identicalSimilar

Outlines of the closest twins

Dianké Makan fire, January 2025
2,207 ha 4 days FWI 63.8 Min. humidity 14 % 26 km away, in 2025

First rain (1 mm or more) after it ended: none in the following ten days.

What happened to them

5 days
median duration
2,714 ha
median area
100 %
went past 1,000 ha
—
rain at the end (median; 0 of 37 had it)

It burned an area similar to its twins (2,912 ha against a median of 2,714 ha) and lasted 4 days, against 5 days.

In none of them did 1 mm fall in the ten days after the end: they all went out without rain.

This is a bank of analogues: it shows what usually happens, not what will happen. With fewer than 15 twins we give no figures. How we calculate it

How it ended

—first rain
—no rain in ten days
34km/h · max. gust

It was considered over on 18 Mar, and not even 1 mm fell in the following ten days: it went out without rain. None of its 37 twins had rain when they ended.

Weather on this page: Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

How a twin is chosen

  • Same area: fires that have already ended, less than 250 km from this one, since 2016.
  • Same start: we compare the FWI on the first day, the minimum humidity that day and the run of days without rain before it. The slider sets how much they may differ.
  • Only pages with final weather data (ERA5 reanalysis) calculated in the same way as this fire’s; agricultural and grass burns and pages with data under review are left out.
  • Fires burning at the same time as this one (a week before or after) are left out: they share the same spell of weather and do not count as a precedent.
  • They are sorted by similarity, and the outlines of the first five are drawn.

How we calculate it

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 8 Mar 2025
After · 25 Mar 2025

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 19 March 2025 the air beside the fire reached 121 µg/m³ of PM2.5. That day averaged 67: 4.5 times the WHO daily guideline (15).

PM2.5 peak121 µg/m³
Days over the guideline9 days
PM10842 µg/m³
Optical depth0.65
13 Mar15 Mar17 Mar19 Mar21 Mar
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 96Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Senegal

Frequently asked questions

How long did the Dianké Makan fire last?
GWIS (Copernicus) dates it between 15 March 2025 and 18 March 2025: 4 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 2,912 hectares (29.1 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire entered 2 municipalities: Dianké Makan (2,726 ha, 0.9 %); Missira (203 ha, 0.0 %).
What was the weather like?
During the fire the temperature reached 43.5 °C, humidity dropped to 12 % and gusts hit 34 km/h. The fire danger index (FWI) reached 64, class Extreme.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Senegal (geoBoundaries). It is not an official report.
How did the fires that started in similar weather in this area end?
Fires less than 250 km away that started since 2016 with a similar FWI, humidity and dry spell: 37. Their median duration was 5 days and their median area 2,714 ha; 100 % went past 1,000 ha. In none of them did 1 mm fall in the ten days after the end: they all went out without rain.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Emergency number: 18 · Emergency number and official warnings

Satellite cross-check

History of this page Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy. This is not an emergency service: if there is a fire now, call 18.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates from the perimeter: the VIIRS detections inside it did not change them. 96 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM3 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.