Skip to content
worldfires
MZ · Mozambique · →

Derre fire, 16 September 2025 Derre

Out · last detection 29 Sept 2025, 11:15 UTC

The fire started on 16 September 2025 in Derre, Mozambique, and satellites saw it burning for 14 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 5,205 hectares from heat detections, spread across a single municipality.

It is the 337th largest in Zambézia since 2016 (of 842 with a page). Number 120 in Mozambique in 2025, of 313.

Compare with…
Burnt area
5,205ha
GWIS perimeter (Copernicus)
Duration
14days
16 Sept 2025 – 29 Sept 2025
Municipalities hit
1
districts
Started on
16 Sept
2025
Heat detections
199
in a single hotspot: 37 MW
Danger at start
34
High · FWI index
Average daily power
172MW
detected power per day, on average

Where it burned

29 Sept 2025
HOTSPOTS BY DAY 16 Sept29 Sept

How it evolved, day by day

16 Sept 2025 · 268 MW · 17 17 Sept 2025 · 281 MW · 30 18 Sept 2025 · 16 MW · 4 21 Sept 2025 · 72 MW · 8 22 Sept 2025 · 193 MW · 21 23 Sept 2025 · 330 MW · 34 24 Sept 2025 · 48 MW · 4 25 Sept 2025 · 156 MW · 14 28 Sept 2025 · 197 MW · 21 29 Sept 2025 · 164 MW · 21
16 Sept 18 Sept 22 Sept 23 Sept 24 Sept 28 Sept

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

37°high
45km/h · peak gust
21%lowest humidity

It had gone 28 days without rain (1 mm or more) when it started. Rain came after the fire: 5.6 mm on 30 Sept.

This area had burned before

94% of the perimeter overlaps earlier fires recorded since 2016: 2,530 ha in 2016, 305 ha in 2017, 608 ha in 2018, 458 ha in 2020, 2,274 ha in 2021, 1,958 ha in 2022, 238 ha in 2023, 2,436 ha in 2024. Part of it burned more than once, so the yearly figures add up to more than the 4,878 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 3.3% of the area of London (52 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Derre where it started
    5,233 ha reached on 9 Sept
    1.1 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance is from the town centre to the nearest fire: staying a kilometre away does not mean it reached the houses.

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
16 Sept 35.1 °C 26 % 25 km/h 0.0 mm High 34
17 Sept 37.1 °C 21 % 40 km/h 0.0 mm Very high 43
18 Sept 36.5 °C 23 % 38 km/h 0.0 mm Very high 46
19 Sept 32.8 °C 38 % 42 km/h 0.0 mm Very high 39
20 Sept 30.3 °C 38 % 41 km/h 0.6 mm High 28
21 Sept 30.9 °C 36 % 35 km/h 0.2 mm High 30
22 Sept 34.0 °C 32 % 28 km/h 0.0 mm High 33
23 Sept 36.8 °C 24 % 33 km/h 0.0 mm Very high 40
24 Sept 36.0 °C 26 % 31 km/h 0.0 mm Very high 40
25 Sept 33.9 °C 32 % 45 km/h 0.0 mm Very high 44
26 Sept 27.4 °C 59 % 37 km/h 2.7 mm Low 7
27 Sept 28.2 °C 50 % 33 km/h 1.3 mm Low 10
28 Sept 33.4 °C 35 % 26 km/h 0.0 mm High 26
29 Sept 37.0 °C 25 % 45 km/h 0.0 mm Very high 44
30 Sept after 27.9 °C 64 % 37 km/h 5.6 mm Very low 4

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 9 Sept 2025
After · 6 Oct 2025

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 22 September 2025 the air beside the fire reached 131 µg/m³ of PM2.5. That day averaged 54: 3.6 times the WHO daily guideline (15).

PM2.5 peak131 µg/m³
Days over the guideline11 days
PM10136 µg/m³
Optical depth1.59
141516171819202122232425262728293012
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 199Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Mozambique ›

Frequently asked questions

How long did the Derre fire last?
GWIS (Copernicus) dates it between 16 September 2025 and 29 September 2025: 14 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 5,205 hectares (52.0 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Derre (5,233 ha, 1.1 %).
What was the weather like?
During the fire the temperature reached 37.1 °C, humidity dropped to 21 % and gusts hit 45 km/h. The fire danger index (FWI) reached 46, class Very high.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Mozambique (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates from the perimeter: the VIIRS detections inside it did not change them. 199 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.

How we build fire pages: methodology ›

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.