Skip to content
worldfires
ET · Ethiopia · –

Debre Elias fire, December 2024 Debre Elias, Bure, Amuru

Out · last detection 1 Jan 2025, 11:01 UTC

The fire started on 24 December 2024 in Debre Elias, Ethiopia, and satellites saw it burning for 9 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 2,893 hectares from heat detections, spread across 3 municipalities.

It is the 84th largest in Amhara since 2016 (of 159 with a page). Number 37 in Ethiopia in 2024, of 87.

Compare with…
Burnt area
2,893ha
GWIS perimeter (Copernicus)
Duration
9days
24 Dec 2024 – 1 Jan 2025
Municipalities hit
3
districts
Started on
24 Dec
2024
Heat detections
104
in a single hotspot: 137 MW
Danger at start
30
High · FWI index
Average daily power
205MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 24 Dec1 Jan
1 Jan 2025

How it evolved, day by day

24 Dec 2024 · 17 MW · 4 25 Dec 2024 · 2 MW · 2 26 Dec 2024 · 118 MW · 14 27 Dec 2024 · 4 MW · 1 31 Dec 2024 · 953 MW · 70 1 Jan 2025 · 137 MW · 13
24 Dec 26 Dec 31 Dec

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

31°high
26km/h · peak gust
16%lowest humidity

It had gone 26 days without rain (1 mm or more) when it started.

This area had burned before

100% of the perimeter overlaps earlier fires recorded since 2016: 2,514 ha in 2016, 2,391 ha in 2017, 2,597 ha in 2018, 1,332 ha in 2020, 2,660 ha in 2021, 2,282 ha in 2022, 1,163 ha in 2023. Part of it burned more than once, so the yearly figures add up to more than the 2,908 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 1.8% of the area of London (29 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Debre Elias where it started
    2,695 ha reached on 26 Dec
    2.3 %
  2. 211 ha reached on 24 Dec
    0.3 %
  3. 6 ha reached on 1 Jan
    0.0 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area< 0.1 ha
Residents< 20

Inside the perimeter there was no noticeable built-up land and almost nobody lived there (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
24 Dec 30.5 °C 28 % 22 km/h 0.0 mm High 30
25 Dec 30.7 °C 29 % 26 km/h 0.0 mm High 30
26 Dec 30.9 °C 30 % 18 km/h 0.0 mm High 29
27 Dec 30.4 °C 33 % 16 km/h 0.0 mm High 27
28 Dec 30.3 °C 30 % 17 km/h 0.0 mm High 28
29 Dec 30.6 °C 30 % 17 km/h 0.0 mm High 27
30 Dec 30.3 °C 16 % 20 km/h 0.0 mm High 32
31 Dec 31.3 °C 17 % 20 km/h 0.0 mm High 33
1 Jan 30.9 °C 21 % 21 km/h 0.0 mm High 33
2 Jan after 31.3 °C 19 % 29 km/h 0.0 mm High 35
3 Jan after 31.8 °C 17 % 30 km/h 0.0 mm High 36
4 Jan after 31.6 °C 20 % 22 km/h 0.0 mm High 34
5 Jan after 31.5 °C 22 % 23 km/h 0.0 mm High 35
6 Jan after 31.4 °C 21 % 27 km/h 0.0 mm Very high 39
7 Jan after 31.1 °C 21 % 36 km/h 0.0 mm Very high 40
8 Jan after 30.8 °C 24 % 28 km/h 0.0 mm High 36
9 Jan after 31.3 °C 23 % 26 km/h 0.0 mm Very high 38
10 Jan after 30.9 °C 26 % 32 km/h 0.0 mm High 38
11 Jan after 31.3 °C 25 % 26 km/h 0.0 mm High 37

Its twins: fires that started in the same weather

It started with an FWI of 29.6, a minimum humidity of 28% and 26 days without rain. Fires in the area that started in weather like this since 2016: 23.

FWI at the start 29.6
Minimum humidity 28 %
Days without rain 26
this fire chosen twins rest of the area
Almost identicalSimilar

Outlines of the closest twins

Dibat fire, January 2020
2,783 ha 15 days FWI 29.1 Min. humidity 28 % 89 km away, in 2020

First rain (1 mm or more) after it ended: none in the following ten days.

What happened to them

11 days
median duration
2,733 ha
median area
100 %
went past 1,000 ha
4.7 mm
rain at the end (median; 1 of 23 had it)

It burned an area similar to its twins (2,893 ha against a median of 2,733 ha) and lasted 9 days, against 11 days.

In 22 of 23, not even 1 mm fell in the ten days after the end: they went out without rain. In the rest, the first rainy day brought a median of 4.7 mm.

This is a bank of analogues: it shows what usually happens, not what will happen. With fewer than 15 twins we give no figures. How we calculate it

How it ended

—first rain
—no rain in ten days
26km/h · max. gust

It was considered over on 1 Jan, and not even 1 mm fell in the following ten days: it went out without rain. Twins with rain when they ended: 1 of 23, with a median of 4.7 mm.

Weather on this page: Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

How a twin is chosen

  • Same area: fires that have already ended, less than 250 km from this one, since 2016.
  • Same start: we compare the FWI on the first day, the minimum humidity that day and the run of days without rain before it. The slider sets how much they may differ.
  • Only pages with final weather data (ERA5 reanalysis) calculated in the same way as this fire’s; agricultural and grass burns and pages with data under review are left out.
  • Fires burning at the same time as this one (a week before or after) are left out: they share the same spell of weather and do not count as a precedent.
  • They are sorted by similarity, and the outlines of the first five are drawn.

How we calculate it

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 17 Dec 2024
After · 8 Jan 2025

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 1 January 2025 the air beside the fire reached 73 µg/m³ of PM2.5. That day averaged 43: 2.9 times the WHO daily guideline (15).

PM2.5 peak73 µg/m³
Days over the guideline7 days
PM1074 µg/m³
Optical depth0.38
29 Dec31 Dec2 Jan4 Jan
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 104Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Ethiopia

Frequently asked questions

How long did the Debre Elias fire last?
According to the heat detections seen by satellite inside the perimeter, it burned from 24 December 2024 to 1 January 2025 (9 days). The perimeter dates it from 31 December 2024 to 1 January 2025.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 2,893 hectares (28.9 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire entered 3 municipalities: Debre Elias (2,695 ha, 2.3 %); Bure (211 ha, 0.3 %); Amuru (6 ha, 0.0 %).
What was the weather like?
During the fire the temperature reached 31.3 °C, humidity dropped to 16 % and gusts hit 26 km/h. The fire danger index (FWI) reached 33, class High.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Ethiopia (geoBoundaries). It is not an official report.
How did the fires that started in similar weather in this area end?
Fires less than 250 km away that started since 2016 with a similar FWI, humidity and dry spell: 23. Their median duration was 11 days and their median area 2,733 ha; 100 % went past 1,000 ha. In 22 of 23, not even 1 mm fell in the ten days after the end: they went out without rain. In the rest, the first rainy day brought a median of 4.7 mm.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

History of this page · 1 Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.
  1. Start date: 31 December 2024 → 24 December 2024.

RSS Changes to this page With cross-checks and a citable version

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates adjusted with the VIIRS detections inside the perimeter, which said 31 December 2024 to 1 January 2025. 104 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM3 (Open Data Commons Open Database License 1.0). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.