Skip to content
worldfires
SN · Senegal · →

Bonconto fire, 25 January 2026 Bonconto

Out · last detection 1 Feb 2026, 14:05 UTC

The fire started on 25 January 2026 in Bonconto, Senegal, and satellites saw it burning for 8 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 8,725 hectares from heat detections, spread across a single municipality.

It is the 5th largest in Kolda since 2016 (of 195 with a page). Number 15 in Senegal in 2026, of 126.

The power measured by the satellite is low (16.6 MW in the strongest hotspot), more typical of grass or stubble burning, or a slow surface fire, than of a large crown fire.

Compare with…
Burnt area
8,725ha
GWIS perimeter (Copernicus)
Duration
8days
25 Jan 2026 – 1 Feb 2026
Municipalities hit
1
districts
Started on
25 Jan
2026
Heat detections
176
in a single hotspot: 17 MW
Danger at start
52
Extreme · FWI index
Average daily power
70MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 25 Jan1 Feb
1 Feb 2026

How it evolved, day by day

25 Jan 2026 · 11 MW · 10 26 Jan 2026 · 68 MW · 21 27 Jan 2026 · 114 MW · 22 28 Jan 2026 · 64 MW · 23 29 Jan 2026 · 100 MW · 33 30 Jan 2026 · 113 MW · 20 31 Jan 2026 · 39 MW · 12 1 Feb 2026 · 54 MW · 13
25 Jan 27 Jan 29 Jan 31 Jan

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

39°high
45km/h · peak gust
15%lowest humidity

It had gone 16 days without rain (1 mm or more) when it started.

This area had burned before

43% of the perimeter overlaps earlier fires recorded since 2016: 1,434 ha in 2017, 771 ha in 2021, 580 ha in 2022, 821 ha in 2024, 1,163 ha in 2025. Part of it burned more than once, so the yearly figures add up to more than the 3,756 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 5.5% of the area of London (87 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Bonconto where it started
    8,771 ha reached on 21 Jan
    3.0 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area1.2 ha
Residents≈ 200

Inside the perimeter there were about 1.2 hectares of built-up land and about 200 residents (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
25 Jan 32.4 °C 20 % 45 km/h 0.0 mm Extreme 52
26 Jan 35.4 °C 19 % 42 km/h 0.0 mm Extreme 51
27 Jan 36.5 °C 18 % 40 km/h 0.0 mm Very high 50
28 Jan 37.3 °C 16 % 34 km/h 0.0 mm Very high 48
29 Jan 37.9 °C 15 % 30 km/h 0.0 mm Very high 46
30 Jan 38.6 °C 15 % 31 km/h 0.0 mm Very high 49
31 Jan 39.0 °C 15 % 33 km/h 0.0 mm Extreme 50
1 Feb 37.3 °C 19 % 20 km/h 0.0 mm Very high 45
2 Feb after 37.9 °C 21 % 20 km/h 0.0 mm Very high 46
3 Feb after 38.8 °C 18 % 20 km/h 0.0 mm Very high 45
4 Feb after 31.3 °C 37 % 33 km/h 0.0 mm Very high 38
5 Feb after 36.1 °C 29 % 33 km/h 0.1 mm Very high 41
6 Feb after 36.1 °C 19 % 37 km/h 0.0 mm Very high 46
7 Feb after 39.5 °C 19 % 35 km/h 0.0 mm Very high 49
8 Feb after 37.7 °C 20 % 32 km/h 0.0 mm Very high 46
9 Feb after 38.6 °C 16 % 37 km/h 0.0 mm Extreme 52
10 Feb after 38.7 °C 14 % 34 km/h 0.0 mm Extreme 52
11 Feb after 39.0 °C 16 % 25 km/h 0.0 mm Very high 48

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 18 Jan 2026
After · 8 Feb 2026

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 25 January 2026 the air beside the fire reached 81 µg/m³ of PM2.5. That day averaged 62: 4.1 times the WHO daily guideline (15).

PM2.5 peak81 µg/m³
Days over the guideline13 days
PM10284 µg/m³
Optical depth0.54
2324252627282930311234
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 176Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Senegal ›

Frequently asked questions

How long did the Bonconto fire last?
GWIS (Copernicus) dates it between 25 January 2026 and 1 February 2026: 8 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 8,725 hectares (87.2 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Bonconto (8,771 ha, 3.0 %).
What was the weather like?
During the fire the temperature reached 39.0 °C, humidity dropped to 15 % and gusts hit 45 km/h. The fire danger index (FWI) reached 52, class Extreme.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Senegal (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Emergency number: 18 · Emergency number and official warnings ›

Satellite cross-check

History of this page Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.

No changes since 24 October 2026.

RSS Changes to this page

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy. This is not an emergency service: if there is a fire now, call 18.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates from the perimeter: the VIIRS detections inside it did not change them. 176 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology ›

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM3 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.