Skip to content
worldfires
DZ · Algeria ·

Ain El Kerma fire, November 2020 عين الكرمة · Ain El Kerma

Out · last detection

The fire started on in Ain El Kerma, Algeria, and satellites saw it burning for 1 day. Copernicus mapped a burnt perimeter of 152 hectares from satellite imagery, spread across a single municipality.

Number 170 in Algeria in 2020, of 236.

Compare with…
Burnt area
152ha
Copernicus perimeter
Duration
1day
7 Nov 2020 – 7 Nov 2020
Municipalities hit
1
communes
Started on
7 Nov
2020
Heat detections
4
in a single hotspot: 75 MW
Danger at start
23
High · FWI index
Average daily power
166MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 7 Nov7 Nov

How it evolved, day by day

7 Nov 2020 · 166 MW · 4

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

27°high
55km/h · peak gust
21%lowest humidity

It had gone 15 days without rain (1 mm or more) when it started.

This area had burned before

No earlier perimeters overlap this fire since 2016, when the satellite record begins.

What happened to each town

  1. Ain El Kerma عين الكرمة 7,530 inhabitants · 6.0 km from the centre where it started
    152 ha reached on 7 Nov
    1.4 %

Burnt area inside each municipality, from crossing the official perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

What burned

  • Mixed forest71 %
  • Other natural land29 %

Land cover inside the perimeter as reported by Copernicus EFFIS (outside the Corine Land Cover area).

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Started with Strong wind: 18 % of the area in Algeria

Day High Min. humidity Peak gust Rain Danger (FWI)
7 Nov 26.8 °C 21 % 55 km/h 0.0 mm High 23
8 Nov after 21.5 °C 57 % 30 km/h 0.0 mm Moderate 21
9 Nov after 20.4 °C 63 % 26 km/h 0.0 mm Moderate 15
10 Nov after 20.0 °C 59 % 30 km/h 0.0 mm Moderate 17
11 Nov after 21.1 °C 61 % 37 km/h 0.0 mm Moderate 20
12 Nov after 21.0 °C 57 % 29 km/h 0.0 mm Moderate 14
13 Nov after 20.6 °C 60 % 24 km/h 0.0 mm Moderate 16
14 Nov after 20.9 °C 66 % 28 km/h 0.0 mm Moderate 18
15 Nov after 22.4 °C 60 % 26 km/h 0.0 mm Moderate 16
16 Nov after 24.9 °C 40 % 39 km/h 0.0 mm High 29
17 Nov after 22.5 °C 56 % 24 km/h 0.0 mm Moderate 19

Its twins: fires that started in the same weather

It started with an FWI of 23.3, a minimum humidity of 21% and 15 days without rain. Fires in the area that started in weather like this since 2016: 14.

FWI at the start 23.3
Minimum humidity 21 %
Days without rain 15
this fire chosen twins rest of the area
Almost identicalSimilar

Outlines of the closest twins

Nacimiento fire, August 2026
300 ha 10 days FWI 26.8 Min. humidity 21 % 225 km away, in 2026

First rain (1 mm or more) after it ended: 3.1 mm on 9 Sept.

What happened to them

Fires in the area that started in similar weather: 14. With fewer than 15 we give no figures: they would be more noise than signal.

This is a bank of analogues: it shows what usually happens, not what will happen. With fewer than 15 twins we give no figures. How we calculate it

How it ended

—first rain
—no rain in ten days
55km/h · max. gust

It was considered over on 7 Nov, and not even 1 mm fell in the following ten days: it went out without rain.

Weather on this page: Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

How a twin is chosen

  • Same area: fires that have already ended, less than 250 km from this one, since 2016.
  • Same start: we compare the FWI on the first day, the minimum humidity that day and the run of days without rain before it. The slider sets how much they may differ.
  • Only pages with final weather data (ERA5 reanalysis) calculated in the same way as this fire’s; agricultural and grass burns and pages with data under review are left out.
  • Fires burning at the same time as this one (a week before or after) are left out: they share the same spell of weather and do not count as a precedent.
  • They are sorted by similarity, and the outlines of the first five are drawn.

How we calculate it

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 31 Oct 2020
After · 14 Nov 2020

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 6 November 2020 the air beside the fire reached 46 µg/m³ of PM2.5. That day averaged 36: 2.4 times the WHO daily guideline (15).

PM2.5 peak46 µg/m³
Days over the guideline3 days
PM1080 µg/m³
5 Nov7 Nov9 Nov
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 4Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Algeria

Frequently asked questions

How long did the Ain El Kerma fire last?
Copernicus dates it between 7 November 2020 and 7 November 2020: 1 day between the first and last image with fire.
How much area did it burn?
The perimeter Copernicus measured from satellite imagery is 152 hectares (1.5 km²). Official national figures may differ.
Which municipalities burned?
The fire only entered Ain El Kerma (152 ha, 1.4 %).
Did the fire reach a town?
The fire started in Ain El Kerma and came within 6.0 km of its centre. That is the distance from the perimeter, or the nearest hotspot, to the point marking the centre; it does not mean it entered the houses.
What was the weather like?
During the fire the temperature reached 26.8 °C, humidity dropped to 21 % and gusts hit 55 km/h. The fire danger index (FWI) reached 23, class High.
Where does this data come from?
From the EFFIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Algeria (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Emergency number: 14 · 1021 · Emergency number and official warnings

Satellite cross-check

History of this page Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy. This is not an emergency service: if there is a fire now, call 14 · 1021.

How we know this
  • Perimeter: EFFIS (Copernicus), mapped on satellite imagery.
  • Dates from the perimeter: the VIIRS detections inside it did not change them. 4 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.

How we build fire pages: methodology

Where this data comes from

The perimeter and land cover come from the Copernicus European Forest Fire Information System (EFFIS), measured on MODIS and Sentinel-2 imagery and published under CC BY 4.0. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM3 (Creative Commons Attribution-ShareAlike 2.0). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ slightly from each country’s official figure.