Skip to content
worldfires
MM · Myanmar (Burma) · →

Ye fire, April 2026 Ye

Out · last detection 2 May 2026, 18:45 UTC

The fire started on 23 April 2026 in Ye, Myanmar (Burma), and satellites saw it burning for 12 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 2,137 hectares from heat detections, spread across a single municipality.

Number 375 in Myanmar (Burma) in 2026, of 418.

Burnt area
2,137ha
GWIS perimeter (Copernicus)
Duration
12days
23 Apr 2026 – 4 May 2026
Municipalities hit
1
municipalities
Started on
23 Apr
2026
Heat detections
33
in a single hotspot: 30 MW
Energy released
196MW
sum of detected power

Where it burned

2 May 2026
HOTSPOTS BY DAY 23 Apr4 May

How it evolved, day by day

23252627283012

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

This area had burned before

74% of the perimeter overlaps earlier fires recorded since 2016: 143 ha in 2016, 211 ha in 2020, 242 ha in 2023, 1,354 ha in 2024. Part of it burned more than once, so the yearly figures add up to more than the 1,583 ha that had burned before.

What happened to each town

  1. Ye where it started
    2,148 ha reached on 23 Apr
    0.8 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance is from the town centre to the nearest fire: staying a kilometre away does not mean it reached the houses.

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 16 Apr 2026
After · 11 May 2026

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 21 April 2026 the air beside the fire reached 88 µg/m³ of PM2.5. That day averaged 45: 3.0 times the WHO daily guideline (15).

PM2.5 peak88 µg/m³
Days over the guideline16 days
PM1097 µg/m³
Optical depth1.05
212223242526272829301234567
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 33Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Myanmar (Burma) ›

Frequently asked questions

How long did the Ye fire last?
GWIS (Copernicus) dates it between 23 April 2026 and 4 May 2026: 12 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 2,137 hectares (21.4 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Ye (2,148 ha, 0.8 %).
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Myanmar (Burma) (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM3 (Creative Commons Attribution 4.0 (CC BY 4.0)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.