Xalisco fire, April 2025 Xalisco

Out · last detection 10 Apr 2025, 20:16 UTC

The fire started on 4 April 2025 in Xalisco, Mexico, and satellites saw it burning for 7 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 1,878 hectares from heat detections, spread across a single municipality.

It is the 136th largest in Nayarit since 2016 (of 181 with a page). Number 125 in Mexico in 2025, of 166.

Compare with…
Burnt area
1,878ha
GWIS perimeter (Copernicus)
Duration
7days
4 Apr 2025 – 10 Apr 2025
Municipalities hit
1
municipalities
Started on
4 Apr
2025
Heat detections
115
in a single hotspot: 121 MW
Danger at start
20
Moderate · FWI index
Average daily power
332MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 4 Apr10 Apr
10 Apr 2025

How it evolved, day by day

4 Apr 2025 · 624 MW · 20 5 Apr 2025 · 529 MW · 34 6 Apr 2025 · 425 MW · 53 7 Apr 2025 · 42 MW · 7 10 Apr 2025 · 40 MW · 1
4 Apr 5 Apr 6 Apr 7 Apr 10 Apr

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

23°high
41km/h · peak gust
42%lowest humidity

It had gone more than two months without rain (1 mm or more) when it started.

This area had burned before

59% of the perimeter overlaps earlier fires recorded since 2016: 1,150 ha in 2017.

How big is it?

10 km
It burned the equivalent of 1.2% of the area of London (19 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Xalisco 65,229 inhabitants where it started
    1,888 ha reached on 4 Apr
    3.7 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area0.74 ha
Residents≈ 20

Inside the perimeter there were about 0.74 hectares of built-up land and about 20 residents (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
4 Apr 22.4 °C 52 % 41 km/h 0.0 mm Moderate 20
5 Apr 21.3 °C 57 % 39 km/h 0.0 mm Moderate 18
6 Apr 20.5 °C 53 % 37 km/h 0.0 mm Moderate 18
7 Apr 22.9 °C 42 % 39 km/h 0.0 mm Moderate 20
8 Apr 24.4 °C 35 % 40 km/h 0.0 mm High 24
9 Apr 24.5 °C 37 % 37 km/h 0.0 mm High 24
10 Apr 24.9 °C 39 % 37 km/h 0.0 mm High 24
11 Apr after 26.6 °C 39 % 38 km/h 0.0 mm High 24
12 Apr after 26.4 °C 32 % 38 km/h 0.0 mm High 26
13 Apr after 24.2 °C 38 % 35 km/h 0.0 mm High 26
14 Apr after 24.1 °C 41 % 34 km/h 0.0 mm High 25
15 Apr after 25.4 °C 40 % 37 km/h 0.0 mm High 27
16 Apr after 22.9 °C 51 % 32 km/h 0.0 mm High 22
17 Apr after 24.1 °C 37 % 34 km/h 0.0 mm High 23

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 28 Mar 2025
After · 17 Apr 2025

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 6 April 2025 the air beside the fire reached 64 µg/m³ of PM2.5. That day averaged 36: 2.4 times the WHO daily guideline (15).

PM2.5 peak64 µg/m³
Days over the guideline5 days
PM1067 µg/m³
Optical depth0.26
2345678910
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 115Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Mexico ›

Frequently asked questions

How long did the Xalisco fire last?
According to the heat detections seen by satellite inside the perimeter, it burned from 4 April 2025 to 10 April 2025 (7 days). The perimeter dates it from 4 April 2025 to 7 April 2025.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 1,878 hectares (18.8 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Xalisco (1,888 ha, 3.7 %).
What was the weather like?
During the fire the temperature reached 22.9 °C, humidity dropped to 42 % and gusts hit 41 km/h. The fire danger index (FWI) reached 20, class Moderate.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Mexico (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Emergency number: 911 · Emergency number and official warnings ›

Satellite cross-check

History of this page · 1 Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.
  1. Last day with fire: 7 April 2025 → 10 April 2025.

RSS Changes to this page

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy. This is not an emergency service: if there is a fire now, call 911.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates adjusted with the VIIRS detections inside the perimeter, which said 4 April 2025 to 7 April 2025. 115 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology ›

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 4.0 (CC BY 4.0)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.