Skip to content
worldfires
LR · Liberia · –

Voinjama fire, 24 February 2019 Voinjama

Out · last detection 12 Mar 2019, 14:10 UTC

The fire started on 24 February 2019 in Voinjama, Liberia, and satellites saw it burning for 16 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 1,361 hectares from heat detections, spread across a single municipality.

It is the 106th largest in Lofa since 2016 (of 202 with a page). Number 24 in Liberia in 2019, of 64.

Burnt area
1,361ha
GWIS perimeter (Copernicus)
Duration
16days
24 Feb 2019 – 11 Mar 2019
Municipalities hit
1
districts
Started on
24 Feb
2019
Heat detections
55
in a single hotspot: 90 MW
Danger at start
35
High · FWI index
Average daily power
87MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 24 Feb11 Mar
12 Mar 2019

How it evolved, day by day

24 Feb 2019 · 63 MW · 2 25 Feb 2019 · 8 MW · 1 26 Feb 2019 · 5 MW · 1 28 Feb 2019 · 27 MW · 3 1 Mar 2019 · 155 MW · 8 2 Mar 2019 · 314 MW · 18 3 Mar 2019 · 100 MW · 6 4 Mar 2019 · 4 MW · 1 6 Mar 2019 · 266 MW · 5 7 Mar 2019 · 21 MW · 2 8 Mar 2019 · 143 MW · 6 11 Mar 2019 · 14 MW · 1 12 Mar 2019 · 8 MW · 1
24 Feb 2 Mar 7 Mar 12 Mar

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

38°high
38km/h · peak gust
12%lowest humidity

It had gone 3 days without rain (1 mm or more) when it started. Rain came after the fire: 5.0 mm on 12 Mar.

This area had burned before

40% of the perimeter overlaps earlier fires recorded since 2016: 207 ha in 2017, 421 ha in 2018. Part of it burned more than once, so the yearly figures add up to more than the 547 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 0.9% of the area of London (14 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Voinjama where it started
    1,370 ha reached on 24 Feb
    0.7 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2020
Built-up area1.5 ha
Residents≈ 350

Inside the perimeter there were about 1.5 hectares of built-up land and about 350 residents (GHSL 2020, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
24 Feb 34.4 °C 28 % 26 km/h 0.0 mm High 35
25 Feb 35.3 °C 26 % 28 km/h 0.0 mm High 35
26 Feb 34.9 °C 24 % 28 km/h 0.0 mm High 33
27 Feb 34.3 °C 24 % 29 km/h 0.0 mm High 36
28 Feb 33.1 °C 22 % 33 km/h 0.0 mm High 36
1 Mar 36.0 °C 12 % 28 km/h 0.0 mm Very high 39
2 Mar 35.5 °C 16 % 18 km/h 0.0 mm Very high 40
3 Mar 35.4 °C 16 % 20 km/h 0.0 mm Very high 42
4 Mar 35.8 °C 18 % 24 km/h 0.0 mm Very high 45
5 Mar 36.3 °C 20 % 26 km/h 0.0 mm Very high 43
6 Mar 38.0 °C 17 % 24 km/h 0.0 mm Very high 46
7 Mar 37.9 °C 23 % 38 km/h 0.0 mm Very high 49
8 Mar 36.2 °C 24 % 31 km/h 0.0 mm Very high 45
9 Mar 36.2 °C 17 % 33 km/h 0.0 mm Very high 45
10 Mar 33.3 °C 38 % 30 km/h 0.2 mm High 33
11 Mar 35.0 °C 34 % 31 km/h 0.3 mm High 30
12 Mar after 34.9 °C 39 % 30 km/h 5.0 mm Low 10

Its twins: fires that started in the same weather

It started with an FWI of 35.0, a minimum humidity of 28% and 3 days without rain. Fires in the area that started in weather like this since 2016: 41.

FWI at the start 35.0
Minimum humidity 28 %
Days without rain 3
this fire chosen twins rest of the area
Almost identicalSimilar

Outlines of the closest twins

Voinjama fire, March 2016
1,765 ha 16 days FWI 36.1 Min. humidity 27 % 17 km away, in 2016

First rain (1 mm or more) after it ended: 7.8 mm on 21 Mar.

What happened to them

8 days
median duration
1,723 ha
median area
100 %
went past 1,000 ha
2.7 mm
rain at the end (median; 39 of 41 had it)

It burned an area similar to its twins (1,361 ha against a median of 1,723 ha) and lasted 16 days, against 8 days.

In 2 of 41, not even 1 mm fell in the ten days after the end: they went out without rain. In the rest, the first rainy day brought a median of 2.7 mm.

This is a bank of analogues: it shows what usually happens, not what will happen. With fewer than 15 twins we give no figures. How we calculate it

How it ended

5.0 mmfirst rain
12 Marthe day after it ended
38km/h · max. gust

It was considered over on 11 Mar, and on 12 Mar 5.0 mm fell. We do not know whether the rain or the firefighters put it out. Twins with rain when they ended: 39 of 41, with a median of 2.7 mm.

Weather on this page: Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

How a twin is chosen

  • Same area: fires that have already ended, less than 250 km from this one, since 2016.
  • Same start: we compare the FWI on the first day, the minimum humidity that day and the run of days without rain before it. The slider sets how much they may differ.
  • Only pages with final weather data (ERA5 reanalysis) calculated in the same way as this fire’s; agricultural and grass burns and pages with data under review are left out.
  • Fires burning at the same time as this one (a week before or after) are left out: they share the same spell of weather and do not count as a precedent.
  • They are sorted by similarity, and the outlines of the first five are drawn.

How we calculate it

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 17 Feb 2019
After · 18 Mar 2019

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

Detections table · 55Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Liberia

Frequently asked questions

How long did the Voinjama fire last?
According to the heat detections seen by satellite inside the perimeter, it burned from 24 February 2019 to 11 March 2019 (16 days). The perimeter dates it from 28 February 2019 to 4 March 2019.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 1,361 hectares (13.6 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Voinjama (1,370 ha, 0.7 %).
What was the weather like?
During the fire the temperature reached 38.0 °C, humidity dropped to 12 % and gusts hit 38 km/h. The fire danger index (FWI) reached 49, class Very high.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Liberia (geoBoundaries). It is not an official report.
How did the fires that started in similar weather in this area end?
Fires less than 250 km away that started since 2016 with a similar FWI, humidity and dry spell: 41. Their median duration was 8 days and their median area 1,723 ha; 100 % went past 1,000 ha. In 2 of 41, not even 1 mm fell in the ten days after the end: they went out without rain. In the rest, the first rainy day brought a median of 2.7 mm.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

History of this page · 2 Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.
  1. Last day with fire: 4 March 2019 → 11 March 2019.
  2. Start date: 28 February 2019 → 24 February 2019.

RSS Changes to this page With cross-checks and a citable version

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates adjusted with the VIIRS detections inside the perimeter, which said 28 February 2019 to 4 March 2019. 55 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2020, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.