Skip to content
worldfires
VE · Venezuela · →

Uracoa fire, April 2026 Uracoa, Sotillo

Out · last detection 29 Apr 2026, 17:17 UTC

The fire started on 25 April 2026 in Uracoa, Venezuela, and satellites saw it burning for 5 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 1,754 hectares from heat detections, spread across 2 municipalities.

It is the 128th largest in Monagas since 2016 (of 165 with a page). Number 299 in Venezuela in 2026, of 396.

Burnt area
1,754ha
GWIS perimeter (Copernicus)
Duration
5days
25 Apr 2026 – 29 Apr 2026
Municipalities hit
2
municipalities
Started on
25 Apr
2026
Heat detections
38
in a single hotspot: 57 MW
Danger at start
5
Very low · FWI index
Energy released
425MW
sum of detected power

Where it burned

29 Apr 2026
HOTSPOTS BY DAY 25 Apr29 Apr

How it evolved, day by day

252829

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

32°high
40km/h · peak gust
51%lowest humidity

It had gone 0 days without rain (1 mm or more) when it started. Rain came after the fire: 1.3 mm on 3 May.

This area had burned before

38% of the perimeter overlaps earlier fires recorded since 2016: 662 ha in 2016.

What happened to each town

  1. Uracoa 9,625 inhabitants where it started
    1,424 ha reached on 25 Apr
    0.8 %
  2. Sotillo 24,238 inhabitants
    340 ha reached on 25 Apr
    0.2 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance is from the town centre to the nearest fire: staying a kilometre away does not mean it reached the houses.

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
25 Apr 31.4 °C 57 % 38 km/h 3.4 mm Very low 5
26 Apr 30.8 °C 63 % 37 km/h 10.2 mm Very low 1
27 Apr 31.2 °C 63 % 40 km/h 1.6 mm Very low 4
28 Apr 31.9 °C 51 % 31 km/h 0.3 mm Low 9
29 Apr 32.0 °C 51 % 38 km/h 0.5 mm Moderate 13
30 Apr after 30.9 °C 53 % 36 km/h 0.0 mm Moderate 13
1 May after 31.2 °C 53 % 38 km/h 0.0 mm Moderate 14
2 May after 31.6 °C 54 % 35 km/h 0.7 mm Moderate 12
3 May after 31.0 °C 55 % 38 km/h 1.3 mm Low 9

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 18 Apr 2026
After · 6 May 2026

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 26 April 2026 the air beside the fire reached 21 µg/m³ of PM2.5, but no daily average passed the WHO guideline (15).

PM2.5 peak21 µg/m³
Days over the guideline0 days
PM1027 µg/m³
Optical depth0.38
232425262728293012
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 38Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Venezuela ›

Frequently asked questions

How long did the Uracoa fire last?
GWIS (Copernicus) dates it between 25 April 2026 and 29 April 2026: 5 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 1,754 hectares (17.5 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire entered 2 municipalities: Uracoa (1,424 ha, 0.8 %); Sotillo (340 ha, 0.2 %).
What was the weather like?
During the fire the temperature reached 32.0 °C, humidity dropped to 51 % and gusts hit 40 km/h. The fire danger index (FWI) reached 13, class Moderate.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Venezuela (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Emergency number: 911

Satellite cross-check

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy. This is not an emergency service: if there is a fire now, call 911.

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Open Data Commons Open Database License 1.0). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.