Skip to content
worldfires
SD · Sudan · –

Um Dafoug fire, 2 November 2026 Um Dafoug

Out · last detection 11 Nov 2026, 11:46 UTC

The fire started on 2 November 2026 in Um Dafoug, Sudan, and satellites saw it burning for 10 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 3,069 hectares from heat detections, spread across a single municipality.

Number 178 in Sudan in 2026, of 379.

GWIS near-real-time perimeter, from the layer that changed in August 2025: this fire is not compared with fires from earlier years, because since then the GWIS layer gives more and larger perimeters.

The power measured by the satellite is low (26.6 MW in the strongest hotspot), more typical of grass or stubble burning, or a slow surface fire, than of a large crown fire.

Burnt area
3,069ha
GWIS perimeter (Copernicus)
Duration
10days
2 Nov 2026 – 11 Nov 2026
Municipalities hit
1
localities
Started on
2 Nov
2026
Heat detections
65
in a single hotspot: 27 MW
Danger at start
88
Very extreme · FWI index
Average daily power
256MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 2 Nov11 Nov
11 Nov 2026

How it evolved, day by day

9 Nov 2026 · 322 MW · 22 10 Nov 2026 · 192 MW · 43 11 Nov 2026 · 0 MW · 0
9 Nov 10 Nov 11 Nov

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

40°high
47km/h · peak gust
10%lowest humidity

It had gone 31 days without rain (1 mm or more) when it started.

This area had burned before

53% of the perimeter overlaps earlier fires recorded since 2016: 1,109 ha in 2016, 501 ha in 2023, 910 ha in 2025. Part of it burned more than once, so the yearly figures add up to more than the 1,620 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 1.9% of the area of London (31 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Um Dafoug where it started
    3,088 ha
    0.6 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area< 0.1 ha
Residents< 20

Inside the perimeter there was no noticeable built-up land and almost nobody lived there (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · forecast models, provisional until the ERA5 reanalysis arrives

Started with Very dry air: 55 % of the area in Sudan

Day High Min. humidity Peak gust Rain Danger (FWI)
2 Nov 39.0 °C 14 % 40 km/h 0.0 mm Very extreme 88
3 Nov 39.8 °C 12 % 41 km/h 0.0 mm Very extreme 91
4 Nov 39.7 °C 10 % 39 km/h 0.0 mm Very extreme 88
5 Nov 39.4 °C 10 % 41 km/h 0.0 mm Very extreme 93
6 Nov 39.2 °C 12 % 39 km/h 0.0 mm Very extreme 90
7 Nov 37.2 °C 12 % 43 km/h 0.0 mm Very extreme 97
8 Nov 36.8 °C 13 % 46 km/h 0.0 mm Very extreme 104
9 Nov 36.3 °C 12 % 47 km/h 0.0 mm Very extreme 102
10 Nov 35.3 °C 10 % 45 km/h 0.0 mm Very extreme 102
11 Nov 34.4 °C 11 % 42 km/h 0.0 mm Very extreme 91
12 Nov after 34.2 °C 11 % 40 km/h 0.0 mm Very extreme 88
13 Nov after 35.9 °C 9 % 39 km/h 0.0 mm Very extreme 90
14 Nov after 36.5 °C 8 % 40 km/h 0.0 mm Very extreme 95
15 Nov after 37.4 °C 9 % 38 km/h 0.0 mm Very extreme 90
16 Nov after 38.3 °C 15 % 48 km/h 0.0 mm Very extreme 110
17 Nov after 38.1 °C 15 % 48 km/h 0.0 mm Very extreme 108

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 26 Oct 2026
After · 17 Nov 2026

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 9 November 2026 the air beside the fire reached 44 µg/m³ of PM2.5. That day averaged 29: 1.9 times the WHO daily guideline (15).

PM2.5 peak44 µg/m³
Days over the guideline10 days
PM10139 µg/m³
Optical depth0.44
31 Oct3 Nov6 Nov9 Nov
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 65Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Sudan

Frequently asked questions

How long did the Um Dafoug fire last?
According to the heat detections seen by satellite inside the perimeter, it burned from 2 November 2026 to 11 November 2026 (10 days). The perimeter dates it from 8 November 2026 to 11 November 2026.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 3,069 hectares (30.7 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Um Dafoug (3,088 ha, 0.6 %).
Is the Um Dafoug fire still active?
No fire detections since 11 Nov 2026, 11:46 UTC. A lack of detections is not an official extinction.
What was the weather like?
During the fire the temperature reached 39.8 °C, humidity dropped to 10 % and gusts hit 47 km/h. The fire danger index (FWI) reached 104, class Very extreme.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Sudan (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

History of this page · 2 Changes in area, dates, name, official record or merged pages, compared every night since 11 November 2026.
  1. Area: 2,974 → 3,069 ha.
  2. Page published (2,974 ha).

RSS Changes to this page With cross-checks and a citable version

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates adjusted with the VIIRS detections inside the perimeter, which said 8 November 2026 to 11 November 2026. 65 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: ECMWF IFS model, provisional until the ERA5 reanalysis arrives.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.