Skip to content
worldfires
BF · Burkina Faso · –

Titao fire, 27 January 2025 Titao, Senguènèga

Out · last detection 30 Jan 2025, 13:40 UTC

The fire started on 27 January 2025 in Titao, Burkina Faso, and satellites saw it burning for 4 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 1,311 hectares from heat detections, spread across 2 municipalities.

It is the 22th largest in Yaadga since 2016 (of 30 with a page). Number 50 in Burkina Faso in 2025, of 77.

Burnt area
1,311ha
GWIS perimeter (Copernicus)
Duration
4days
27 Jan 2025 – 30 Jan 2025
Municipalities hit
2
communes
Started on
27 Jan
2025
Heat detections
37
in a single hotspot: 44 MW
Danger at start
87
Very extreme · FWI index
Average daily power
141MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 27 Jan30 Jan
30 Jan 2025

How it evolved, day by day

28 Jan 2025 · 371 MW · 26 29 Jan 2025 · 33 MW · 8 30 Jan 2025 · 18 MW · 3
28 Jan 29 Jan 30 Jan

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

34°high
42km/h · peak gust
8%lowest humidity

It had gone more than two months without rain (1 mm or more) when it started.

This area had burned before

No earlier perimeters overlap this fire since 2016, when the satellite record begins.

How big is it?

10 km
It burned the equivalent of 0.8% of the area of London (13 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Titao where it started
    946 ha reached on 28 Jan
    0.6 %
  2. 372 ha reached on 28 Jan
    0.6 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area14 ha
Residents≈ 1,700

Inside the perimeter there were about 14 hectares of built-up land and about 1,700 residents (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Started with Extreme FWI: 77 % of the area in Burkina Faso Very dry air: 56 % of the area in Burkina Faso 60 days without rain: 26 % of the area in Burkina Faso

Day High Min. humidity Peak gust Rain Danger (FWI)
27 Jan 34.3 °C 8 % 42 km/h 0.0 mm Very extreme 87
28 Jan 33.6 °C 11 % 41 km/h 0.0 mm Very extreme 84
29 Jan 33.7 °C 9 % 39 km/h 0.0 mm Very extreme 81
30 Jan 33.5 °C 11 % 35 km/h 0.0 mm Very extreme 76
31 Jan after 33.3 °C 11 % 30 km/h 0.0 mm Extreme 68
1 Feb after 31.6 °C 13 % 30 km/h 0.0 mm Extreme 67
2 Feb after 28.4 °C 16 % 42 km/h 0.0 mm Very extreme 75
3 Feb after 29.8 °C 15 % 33 km/h 0.0 mm Extreme 64
4 Feb after 34.0 °C 11 % 35 km/h 0.0 mm Extreme 69
5 Feb after 34.0 °C 10 % 37 km/h 0.0 mm Very extreme 75
6 Feb after 34.3 °C 14 % 41 km/h 0.0 mm Very extreme 81
7 Feb after 34.6 °C 11 % 35 km/h 0.0 mm Very extreme 71
8 Feb after 35.7 °C 9 % 34 km/h 0.0 mm Very extreme 72
9 Feb after 37.2 °C 9 % 46 km/h 0.0 mm Very extreme 91

Its twins: fires that started in the same weather

It started with an FWI of 87.0, a minimum humidity of 8% and more than two months without rain. Fires in the area that started in weather like this since 2016: 21.

FWI at the start 87.0
Minimum humidity 8 %
Days without rain 60+
this fire chosen twins rest of the area
Almost identicalSimilar

Outlines of the closest twins

Titao fire, February 2024
2,090 ha 4 days FWI 83.0 Min. humidity 8 % 33 km away, in 2024

First rain (1 mm or more) after it ended: none in the following ten days.

What happened to them

3 days
median duration
1,786 ha
median area
100 %
went past 1,000 ha
—
rain at the end (median; 0 of 21 had it)

It burned an area similar to its twins (1,311 ha against a median of 1,786 ha) and lasted 4 days, against 3 days.

In none of them did 1 mm fall in the ten days after the end: they all went out without rain.

This is a bank of analogues: it shows what usually happens, not what will happen. With fewer than 15 twins we give no figures. How we calculate it

How it ended

—first rain
—no rain in ten days
42km/h · max. gust

It was considered over on 30 Jan, and not even 1 mm fell in the following ten days: it went out without rain. None of its 21 twins had rain when they ended.

Weather on this page: Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

How a twin is chosen

  • Same area: fires that have already ended, less than 250 km from this one, since 2016.
  • Same start: we compare the FWI on the first day, the minimum humidity that day and the run of days without rain before it. The slider sets how much they may differ.
  • Only pages with final weather data (ERA5 reanalysis) calculated in the same way as this fire’s; agricultural and grass burns and pages with data under review are left out.
  • Fires burning at the same time as this one (a week before or after) are left out: they share the same spell of weather and do not count as a precedent.
  • They are sorted by similarity, and the outlines of the first five are drawn.

How we calculate it

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 20 Jan 2025
After · 6 Feb 2025

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 2 February 2025 the air beside the fire reached 84 µg/m³ of PM2.5. That day averaged 72: 4.8 times the WHO daily guideline (15).

PM2.5 peak84 µg/m³
Days over the guideline8 days
PM10466 µg/m³
Optical depth0.64
26 Jan28 Jan30 Jan1 Feb
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 37Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Burkina Faso

Frequently asked questions

How long did the Titao fire last?
According to the heat detections seen by satellite inside the perimeter, it burned from 27 January 2025 to 30 January 2025 (4 days). The perimeter dates it from 28 January 2025 to 30 January 2025.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 1,311 hectares (13.1 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire entered 2 municipalities: Titao (946 ha, 0.6 %); Senguènèga (372 ha, 0.6 %).
What was the weather like?
During the fire the temperature reached 34.3 °C, humidity dropped to 8 % and gusts hit 42 km/h. The fire danger index (FWI) reached 87, class Very extreme.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Burkina Faso (OCHA COD-AB). It is not an official report.
How did the fires that started in similar weather in this area end?
Fires less than 250 km away that started since 2016 with a similar FWI, humidity and dry spell: 21. Their median duration was 3 days and their median area 1,786 ha; 100 % went past 1,000 ha. In none of them did 1 mm fall in the ten days after the end: they all went out without rain.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

History of this page · 1 Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.
  1. Start date: 28 January 2025 → 27 January 2025.

RSS Changes to this page With cross-checks and a citable version

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates adjusted with the VIIRS detections inside the perimeter, which said 28 January 2025 to 30 January 2025. 37 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from OCHA COD-AB (Institut Geographique Burkina (IGB)) (Creative Commons Attribution for Intergovernmental Organisations (CC BY-IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.