Skip to content
worldfires
PG · Papua New Guinea · –

South Fly District fire, 5 September 2026 South Fly District

Out · last detection

The fire started on in South Fly District, Papua New Guinea, and satellites saw it burning for 13 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 7,874 hectares from heat detections, spread across a single municipality.

Number 37 in Papua New Guinea in 2026, of 202.

GWIS near-real-time perimeter, from the layer that changed in October 2025: this fire is not compared with fires from earlier years, because since then the GWIS layer gives more and larger perimeters.

Burnt area
7,874ha
GWIS perimeter (Copernicus)
Duration
13days
5 Sept 2026 – 17 Sept 2026
Municipalities hit
1
districts
Started on
5 Sept
2026
Heat detections
121
in a single hotspot: 55 MW
Danger at start
28
High · FWI index
Average daily power
103MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 5 Sept17 Sept
17 Sept 2026

How it evolved, day by day

5 Sept 2026 · 27 MW · 3 6 Sept 2026 · 112 MW · 13 7 Sept 2026 · 374 MW · 35 8 Sept 2026 · 108 MW · 8 9 Sept 2026 · 147 MW · 16 10 Sept 2026 · 195 MW · 33 11 Sept 2026 · 30 MW · 4 12 Sept 2026 · 28 MW · 5 13 Sept 2026 · 3 MW · 3 17 Sept 2026 · 4 MW · 1
5 Sept 7 Sept 9 Sept 11 Sept 13 Sept

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

Fire front film How it spread from one satellite pass to the next (14 passes) and with what wind. Watch the film

The weather it burned in

33°high
49km/h · peak gust
36%lowest humidity

It had gone 22 days without rain (1 mm or more) when it started.

This area had burned before

No earlier perimeters overlap this fire since 2016, when the satellite record begins.

How big is it?

10 km
It burned the equivalent of 5% of the area of London (79 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. South Fly District where it started
    7,933 ha reached on 5 Sept
    0.2 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area< 0.1 ha
Residents< 20

Inside the perimeter there was no noticeable built-up land and almost nobody lived there (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
5 Sept 30.9 °C 42 % 35 km/h 0.0 mm High 28
6 Sept 32.1 °C 39 % 35 km/h 0.0 mm High 27
7 Sept 31.9 °C 42 % 35 km/h 0.0 mm High 28
8 Sept 31.8 °C 45 % 40 km/h 0.0 mm High 30
9 Sept 33.3 °C 38 % 38 km/h 0.0 mm High 26
10 Sept 32.8 °C 36 % 47 km/h 0.0 mm Very high 43
11 Sept 29.6 °C 47 % 49 km/h 0.3 mm Very high 44
12 Sept 29.1 °C 54 % 43 km/h 1.3 mm High 29
13 Sept 31.1 °C 43 % 44 km/h 0.0 mm High 35
14 Sept 28.5 °C 56 % 49 km/h 0.5 mm Very high 38
15 Sept 30.0 °C 48 % 48 km/h 0.0 mm Very high 38
16 Sept 29.6 °C 54 % 44 km/h 0.5 mm High 38
17 Sept 32.0 °C 41 % 41 km/h 0.0 mm Very high 41
18 Sept after 29.1 °C 56 % 53 km/h 0.5 mm Very high 43
19 Sept after 28.5 °C 56 % 54 km/h 0.6 mm Very high 38
20 Sept after 29.6 °C 52 % 48 km/h 0.3 mm High 32
21 Sept after 30.5 °C 53 % 40 km/h 0.0 mm High 29
22 Sept after 29.4 °C 56 % 42 km/h 0.5 mm High 30
23 Sept after 30.7 °C 50 % 44 km/h 0.0 mm High 32
24 Sept after 30.6 °C 51 % 42 km/h 0.0 mm High 35
25 Sept after 32.8 °C 41 % 45 km/h 0.0 mm Very high 44
26 Sept after 32.1 °C 45 % 45 km/h 0.2 mm Very high 43
27 Sept after 32.0 °C 44 % 48 km/h 0.0 mm Very high 44

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 29 Aug 2026
After · 24 Sept 2026

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 8 September 2026 the air beside the fire reached 85 µg/m³ of PM2.5. That day averaged 39: 2.6 times the WHO daily guideline (15).

PM2.5 peak85 µg/m³
Days over the guideline4 days
PM1090 µg/m³
Optical depth1.24
3 Sept7 Sept11 Sept15 Sept19 Sept
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 121Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Papua New Guinea

Frequently asked questions

How long did the South Fly District fire last?
According to the heat detections seen by satellite inside the perimeter, it burned from 5 September 2026 to 17 September 2026 (13 days). The perimeter dates it from 6 September 2026 to 15 September 2026.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 7,874 hectares (78.7 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered South Fly District (7,933 ha, 0.2 %).
What was the weather like?
During the fire the temperature reached 33.3 °C, humidity dropped to 36 % and gusts hit 49 km/h. The fire danger index (FWI) reached 44, class Very high.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Papua New Guinea (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

History of this page · 1 Changes in area, dates, name, official record or merged pages, compared every night since 5 November 2026.
  1. Page published (7,874 ha).

RSS Changes to this page With cross-checks and a citable version

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates adjusted with the VIIRS detections inside the perimeter, which said 6 September 2026 to 15 September 2026. 121 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.