Skip to content
worldfires
GH · Ghana · –

Sissala East fire, 13 December 2019 Sissala East, Wa East

Out · last detection 20 Dec 2019, 14:03 UTC

The fire started on 13 December 2019 in Sissala East, Ghana, and satellites saw it burning for 11 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 2,172 hectares from heat detections, spread across 2 municipalities.

It is the 75th largest in Upper West Region since 2016 (of 93 with a page). Number 105 in Ghana in 2019, of 127.

Burnt area
2,172ha
GWIS perimeter (Copernicus)
Duration
11days
13 Dec 2019 – 23 Dec 2019
Municipalities hit
2
districts
Started on
13 Dec
2019
Heat detections
50
in a single hotspot: 74 MW
Danger at start
61
Extreme · FWI index
Average daily power
195MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 13 Dec23 Dec
20 Dec 2019

How it evolved, day by day

13 Dec 2019 · 21 MW · 2 14 Dec 2019 · 127 MW · 8 15 Dec 2019 · 161 MW · 22 16 Dec 2019 · 665 MW · 17 20 Dec 2019 · 2 MW · 1
13 Dec 14 Dec 15 Dec 16 Dec 20 Dec

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

36°high
41km/h · peak gust
10%lowest humidity

It had gone 39 days without rain (1 mm or more) when it started.

This area had burned before

65% of the perimeter overlaps earlier fires recorded since 2016: 995 ha in 2016, 648 ha in 2017. Part of it burned more than once, so the yearly figures add up to more than the 1,405 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 1.4% of the area of London (22 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Sissala East where it started
    2,097 ha reached on 13 Dec
    0.4 %
  2. 88 ha reached on 13 Dec
    0.0 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2020
Built-up area< 0.1 ha
Residents< 20

Inside the perimeter there was no noticeable built-up land and almost nobody lived there (GHSL 2020, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Started with Extreme FWI: 39 % of the area in Ghana

Day High Min. humidity Peak gust Rain Danger (FWI)
13 Dec 35.1 °C 16 % 29 km/h 0.0 mm Extreme 61
14 Dec 34.5 °C 14 % 33 km/h 0.0 mm Extreme 63
15 Dec 34.6 °C 10 % 31 km/h 0.0 mm Extreme 64
16 Dec 35.4 °C 13 % 32 km/h 0.0 mm Extreme 66
17 Dec 35.6 °C 14 % 30 km/h 0.0 mm Extreme 63
18 Dec 34.8 °C 16 % 28 km/h 0.0 mm Extreme 62
19 Dec 34.6 °C 17 % 35 km/h 0.0 mm Very extreme 70
20 Dec 35.1 °C 16 % 36 km/h 0.0 mm Very extreme 71
21 Dec 34.1 °C 14 % 35 km/h 0.0 mm Extreme 70
22 Dec 35.0 °C 12 % 34 km/h 0.0 mm Very extreme 71
23 Dec 35.8 °C 12 % 41 km/h 0.0 mm Very extreme 79
24 Dec after 34.6 °C 13 % 33 km/h 0.0 mm Extreme 68
25 Dec after 34.7 °C 11 % 32 km/h 0.0 mm Extreme 64
26 Dec after 34.6 °C 13 % 32 km/h 0.0 mm Extreme 69
27 Dec after 33.3 °C 15 % 31 km/h 0.0 mm Extreme 66
28 Dec after 34.2 °C 17 % 31 km/h 0.0 mm Extreme 65
29 Dec after 34.7 °C 15 % 31 km/h 0.0 mm Extreme 65
30 Dec after 34.2 °C 14 % 37 km/h 0.0 mm Very extreme 73
31 Dec after 33.6 °C 15 % 40 km/h 0.0 mm Very extreme 76
1 Jan after 33.1 °C 13 % 41 km/h 0.0 mm Very extreme 78
2 Jan after 29.8 °C 14 % 43 km/h 0.0 mm Very extreme 79

Its twins: fires that started in the same weather

It started with an FWI of 60.9, a minimum humidity of 16% and 39 days without rain. Fires in the area that started in weather like this since 2016: 37.

FWI at the start 60.9
Minimum humidity 16 %
Days without rain 39
this fire chosen twins rest of the area
Almost identicalSimilar

Outlines of the closest twins

Sissala East fire, December 2021
13,068 ha 22 days FWI 59.7 Min. humidity 16 % 58 km away, in 2021

First rain (1 mm or more) after it ended: none in the following ten days.

What happened to them

9 days
median duration
2,304 ha
median area
100 %
went past 1,000 ha
1.6 mm
rain at the end (median; 1 of 37 had it)

It burned an area similar to its twins (2,172 ha against a median of 2,304 ha) and lasted 11 days, against 9 days.

In 36 of 37, not even 1 mm fell in the ten days after the end: they went out without rain. In the rest, the first rainy day brought a median of 1.6 mm.

This is a bank of analogues: it shows what usually happens, not what will happen. With fewer than 15 twins we give no figures. How we calculate it

How it ended

—first rain
—no rain in ten days
41km/h · max. gust

It was considered over on 23 Dec, and not even 1 mm fell in the following ten days: it went out without rain. Twins with rain when they ended: 1 of 37, with a median of 1.6 mm.

Weather on this page: Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

How a twin is chosen

  • Same area: fires that have already ended, less than 250 km from this one, since 2016.
  • Same start: we compare the FWI on the first day, the minimum humidity that day and the run of days without rain before it. The slider sets how much they may differ.
  • Only pages with final weather data (ERA5 reanalysis) calculated in the same way as this fire’s; agricultural and grass burns and pages with data under review are left out.
  • Fires burning at the same time as this one (a week before or after) are left out: they share the same spell of weather and do not count as a precedent.
  • They are sorted by similarity, and the outlines of the first five are drawn.

How we calculate it

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 6 Dec 2019
After · 30 Dec 2019

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

Detections table · 50Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Ghana

Frequently asked questions

How long did the Sissala East fire last?
According to the heat detections seen by satellite inside the perimeter, it burned from 13 December 2019 to 23 December 2019 (11 days). The perimeter dates it from 13 December 2019 to 16 December 2019.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 2,172 hectares (21.7 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire entered 2 municipalities: Sissala East (2,097 ha, 0.4 %); Wa East (88 ha, 0.0 %).
What was the weather like?
During the fire the temperature reached 35.8 °C, humidity dropped to 10 % and gusts hit 41 km/h. The fire danger index (FWI) reached 79, class Very extreme.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Ghana (geoBoundaries). It is not an official report.
How did the fires that started in similar weather in this area end?
Fires less than 250 km away that started since 2016 with a similar FWI, humidity and dry spell: 37. Their median duration was 9 days and their median area 2,304 ha; 100 % went past 1,000 ha. In 36 of 37, not even 1 mm fell in the ten days after the end: they went out without rain. In the rest, the first rainy day brought a median of 1.6 mm.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Emergency number: 112 · Emergency number and official warnings

Satellite cross-check

History of this page · 1 Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.
  1. Last day with fire: 16 December 2019 → 23 December 2019.

RSS Changes to this page With cross-checks and a citable version

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy. This is not an emergency service: if there is a fire now, call 112.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates adjusted with the VIIRS detections inside the perimeter, which said 13 December 2019 to 16 December 2019. 50 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2020, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 4.0 International (CC BY 4.0)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.