Skip to content
worldfires
GH · Ghana · –

Sissala East fire, 12 December 2018 Sissala East

Out · last detection 27 Dec 2018, 12:36 UTC

The fire started on 12 December 2018 in Sissala East, Ghana, and satellites saw it burning for 16 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 2,214 hectares from heat detections, spread across a single municipality.

It is the 70th largest in Upper West Region since 2016 (of 93 with a page). Number 48 in Ghana in 2018, of 59.

Burnt area
2,214ha
GWIS perimeter (Copernicus)
Duration
16days
12 Dec 2018 – 27 Dec 2018
Municipalities hit
1
districts
Started on
12 Dec
2018
Heat detections
100
in a single hotspot: 44 MW
Danger at start
54
Extreme · FWI index
Average daily power
73MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 12 Dec27 Dec
27 Dec 2018

How it evolved, day by day

12 Dec 2018 · 65 MW · 3 13 Dec 2018 · 85 MW · 11 14 Dec 2018 · 26 MW · 6 16 Dec 2018 · 75 MW · 6 17 Dec 2018 · 385 MW · 31 18 Dec 2018 · 68 MW · 14 19 Dec 2018 · 36 MW · 6 20 Dec 2018 · 37 MW · 7 21 Dec 2018 · 22 MW · 3 22 Dec 2018 · 9 MW · 2 24 Dec 2018 · 68 MW · 10 27 Dec 2018 · 4 MW · 1
12 Dec 17 Dec 22 Dec

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

36°high
40km/h · peak gust
10%lowest humidity

It had gone 43 days without rain (1 mm or more) when it started.

This area had burned before

16% of the perimeter overlaps earlier fires recorded since 2016: 363 ha in 2016.

How big is it?

10 km
It burned the equivalent of 1.4% of the area of London (22 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Sissala East where it started
    2,230 ha reached on 12 Dec
    0.4 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2020
Built-up area1.8 ha
Residents≈ 150

Inside the perimeter there were about 1.8 hectares of built-up land and about 150 residents (GHSL 2020, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
12 Dec 34.6 °C 15 % 38 km/h 0.0 mm Extreme 54
13 Dec 35.4 °C 15 % 36 km/h 0.0 mm Extreme 52
14 Dec 35.6 °C 11 % 40 km/h 0.0 mm Extreme 57
15 Dec 36.1 °C 11 % 40 km/h 0.0 mm Extreme 58
16 Dec 35.9 °C 10 % 36 km/h 0.0 mm Extreme 54
17 Dec 36.4 °C 13 % 34 km/h 0.0 mm Extreme 52
18 Dec 35.4 °C 16 % 36 km/h 0.0 mm Extreme 53
19 Dec 35.1 °C 14 % 35 km/h 0.0 mm Extreme 55
20 Dec 35.7 °C 13 % 34 km/h 0.0 mm Extreme 54
21 Dec 35.0 °C 14 % 36 km/h 0.0 mm Extreme 56
22 Dec 33.7 °C 15 % 37 km/h 0.0 mm Extreme 56
23 Dec 33.5 °C 13 % 35 km/h 0.0 mm Extreme 55
24 Dec 33.0 °C 12 % 35 km/h 0.0 mm Extreme 56
25 Dec 32.3 °C 15 % 36 km/h 0.0 mm Extreme 54
26 Dec 32.7 °C 12 % 35 km/h 0.0 mm Extreme 53
27 Dec 34.2 °C 12 % 33 km/h 0.0 mm Extreme 52
28 Dec after 35.2 °C 13 % 34 km/h 0.0 mm Extreme 52
29 Dec after 34.2 °C 13 % 36 km/h 0.0 mm Extreme 55
30 Dec after 34.1 °C 14 % 37 km/h 0.0 mm Extreme 58
31 Dec after 34.7 °C 13 % 44 km/h 0.0 mm Extreme 62
1 Jan after 34.5 °C 15 % 44 km/h 0.0 mm Extreme 62
2 Jan after 34.3 °C 14 % 34 km/h 0.0 mm Extreme 55
3 Jan after 33.9 °C 13 % 32 km/h 0.0 mm Extreme 55
4 Jan after 33.3 °C 12 % 37 km/h 0.0 mm Extreme 57
5 Jan after 33.8 °C 12 % 36 km/h 0.0 mm Extreme 58
6 Jan after 32.3 °C 13 % 38 km/h 0.0 mm Extreme 59

Its twins: fires that started in the same weather

It started with an FWI of 54.2, a minimum humidity of 15% and 43 days without rain. Fires in the area that started in weather like this since 2016: 29.

FWI at the start 54.2
Minimum humidity 15 %
Days without rain 43
this fire chosen twins rest of the area
Almost identicalSimilar

Outlines of the closest twins

Kassou fire, December 2016
1,065 ha 11 days FWI 54.2 Min. humidity 15 % 89 km away, in 2016

First rain (1 mm or more) after it ended: none in the following ten days.

What happened to them

10 days
median duration
2,046 ha
median area
100 %
went past 1,000 ha
—
rain at the end (median; 0 of 29 had it)

It burned an area similar to its twins (2,214 ha against a median of 2,046 ha) and lasted 16 days, against 10 days.

In none of them did 1 mm fall in the ten days after the end: they all went out without rain.

This is a bank of analogues: it shows what usually happens, not what will happen. With fewer than 15 twins we give no figures. How we calculate it

How it ended

—first rain
—no rain in ten days
40km/h · max. gust

It was considered over on 27 Dec, and not even 1 mm fell in the following ten days: it went out without rain. None of its 29 twins had rain when they ended.

Weather on this page: Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

How a twin is chosen

  • Same area: fires that have already ended, less than 250 km from this one, since 2016.
  • Same start: we compare the FWI on the first day, the minimum humidity that day and the run of days without rain before it. The slider sets how much they may differ.
  • Only pages with final weather data (ERA5 reanalysis) calculated in the same way as this fire’s; agricultural and grass burns and pages with data under review are left out.
  • Fires burning at the same time as this one (a week before or after) are left out: they share the same spell of weather and do not count as a precedent.
  • They are sorted by similarity, and the outlines of the first five are drawn.

How we calculate it

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 5 Dec 2018
After · 3 Jan 2019

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

Detections table · 100Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Ghana

Frequently asked questions

How long did the Sissala East fire last?
According to the heat detections seen by satellite inside the perimeter, it burned from 12 December 2018 to 27 December 2018 (16 days). The perimeter dates it from 17 December 2018 to 22 December 2018.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 2,214 hectares (22.1 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Sissala East (2,230 ha, 0.4 %).
What was the weather like?
During the fire the temperature reached 36.4 °C, humidity dropped to 10 % and gusts hit 40 km/h. The fire danger index (FWI) reached 58, class Extreme.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Ghana (geoBoundaries). It is not an official report.
How did the fires that started in similar weather in this area end?
Fires less than 250 km away that started since 2016 with a similar FWI, humidity and dry spell: 29. Their median duration was 10 days and their median area 2,046 ha; 100 % went past 1,000 ha. In none of them did 1 mm fall in the ten days after the end: they all went out without rain.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Emergency number: 112 · Emergency number and official warnings

Satellite cross-check

History of this page · 2 Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.
  1. Last day with fire: 22 December 2018 → 27 December 2018.
  2. Start date: 17 December 2018 → 12 December 2018.

RSS Changes to this page With cross-checks and a citable version

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy. This is not an emergency service: if there is a fire now, call 112.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates adjusted with the VIIRS detections inside the perimeter, which said 17 December 2018 to 22 December 2018. 100 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2020, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 4.0 International (CC BY 4.0)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.