Skip to content
worldfires
GH · Ghana · –

Savelugu fire, 8 January 2020 Savelugu

Out · last detection

The fire started on in Savelugu, Ghana, and satellites saw it burning for 12 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 2,782 hectares from heat detections, spread across a single municipality.

It is number 80 by size of the 206 fires with a page that started in Northern Region since 2016. Number 56 in Ghana in 2020, of 111.

Burnt area
2,782ha
GWIS perimeter (Copernicus)
Duration
12days
8 Jan 2020 – 19 Jan 2020
Municipalities hit
1
districts
Started on
8 Jan
2020
Heat detections
70
in a single hotspot: 59 MW
Danger at start
55
Extreme · FWI index
Average daily power
129MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 8 Jan19 Jan
14 Jan 2020

How it evolved, day by day

8 Jan 2020 · 7 MW · 2 11 Jan 2020 · 25 MW · 3 12 Jan 2020 · 230 MW · 33 13 Jan 2020 · 255 MW · 23 14 Jan 2020 · 126 MW · 9
8 Jan 11 Jan 12 Jan 13 Jan 14 Jan

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

37°high
35km/h · peak gust
13%lowest humidity

It had gone 55 days without rain (1 mm or more) when it started.

This area had burned before

89% of the perimeter overlaps earlier fires recorded since 2016: 1,960 ha in 2016, 926 ha in 2017, 1,223 ha in 2018. Part of it burned more than once, so the yearly figures add up to more than the 2,481 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 1.8% of the area of London (28 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Savelugu where it started
    2,798 ha reached on 8 Jan
    1.8 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2020
Built-up area0.12 ha
Residents< 20

Inside the perimeter there were about 0.12 hectares of built-up land and almost nobody lived there (GHSL 2020, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Started with Extreme FWI: 39 % of the area in Ghana

Day High Min. humidity Peak gust Rain Danger (FWI)
8 Jan 35.6 °C 20 % 27 km/h 0.0 mm Extreme 55
9 Jan 36.1 °C 17 % 33 km/h 0.0 mm Extreme 65
10 Jan 36.3 °C 17 % 28 km/h 0.0 mm Extreme 59
11 Jan 35.5 °C 24 % 19 km/h 0.0 mm Very high 42
12 Jan 36.8 °C 27 % 21 km/h 0.0 mm Very high 41
13 Jan 36.8 °C 13 % 35 km/h 0.0 mm Extreme 69
14 Jan 34.7 °C 15 % 35 km/h 0.0 mm Extreme 65
15 Jan 35.9 °C 13 % 31 km/h 0.0 mm Extreme 66
16 Jan 35.6 °C 16 % 34 km/h 0.0 mm Extreme 67
17 Jan 35.8 °C 18 % 34 km/h 0.0 mm Very extreme 70
18 Jan 35.0 °C 16 % 32 km/h 0.0 mm Extreme 65
19 Jan 33.6 °C 19 % 32 km/h 0.0 mm Extreme 60
20 Jan after 34.9 °C 20 % 30 km/h 0.0 mm Extreme 56
21 Jan after 36.2 °C 22 % 23 km/h 0.0 mm Extreme 53
22 Jan after 36.7 °C 20 % 37 km/h 0.0 mm Very extreme 71
23 Jan after 36.9 °C 13 % 37 km/h 0.0 mm Very extreme 71
24 Jan after 36.7 °C 11 % 37 km/h 0.0 mm Very extreme 71
25 Jan after 35.5 °C 9 % 43 km/h 0.0 mm Very extreme 85
26 Jan after 35.3 °C 12 % 33 km/h 0.0 mm Extreme 67
27 Jan after 35.1 °C 13 % 29 km/h 0.0 mm Extreme 67
28 Jan after 34.4 °C 12 % 29 km/h 0.0 mm Extreme 66
29 Jan after 36.7 °C 10 % 35 km/h 0.0 mm Very extreme 76

Its twins: fires that started in the same weather

It started with an FWI of 55.1, a minimum humidity of 20% and 55 days without rain. Fires in the area that started in weather like this since 2016: 55.

FWI at the start 55.1
Minimum humidity 20 %
Days without rain 55
this fire chosen twins rest of the area
Almost identicalSimilar

Outlines of the closest twins

Builsa South fire, December 2021
2,000 ha 15 days FWI 55.7 Min. humidity 20 % 76 km away, in 2021

First rain (1 mm or more) after it ended: none in the following ten days.

What happened to them

10 days
median duration
2,506 ha
median area
100 %
went past 1,000 ha
1.7 mm
rain at the end (median; 2 of 55 had it)

It burned an area similar to its twins (2,782 ha against a median of 2,506 ha) and lasted 12 days, against 10 days.

In 53 of 55, not even 1 mm fell in the ten days after the end: they went out without rain. In the rest, the first rainy day brought a median of 1.7 mm.

This is a bank of analogues: it shows what usually happens, not what will happen. With fewer than 15 twins we give no figures. How we calculate it

How it ended

—first rain
—no rain in ten days
35km/h · max. gust

It was considered over on 19 Jan, and not even 1 mm fell in the following ten days: it went out without rain. Twins with rain when they ended: 2 of 55, with a median of 1.7 mm.

Weather on this page: Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

How a twin is chosen

  • Same area: fires that have already ended, less than 250 km from this one, since 2016.
  • Same start: we compare the FWI on the first day, the minimum humidity that day and the run of days without rain before it. The slider sets how much they may differ.
  • Only pages with final weather data (ERA5 reanalysis) calculated in the same way as this fire’s; agricultural and grass burns and pages with data under review are left out.
  • Fires burning at the same time as this one (a week before or after) are left out: they share the same spell of weather and do not count as a precedent.
  • They are sorted by similarity, and the outlines of the first five are drawn.

How we calculate it

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 1 Jan 2020
After · 26 Jan 2020

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

Detections table · 70Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Ghana

Frequently asked questions

How long did the Savelugu fire last?
According to the heat detections seen by satellite inside the perimeter, it burned from 8 January 2020 to 19 January 2020 (12 days). The perimeter dates it from 11 January 2020 to 14 January 2020.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 2,782 hectares (27.8 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Savelugu (2,798 ha, 1.8 %).
What was the weather like?
During the fire the temperature reached 36.8 °C, humidity dropped to 13 % and gusts hit 35 km/h. The fire danger index (FWI) reached 70, class Very extreme.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Ghana (geoBoundaries). It is not an official report.
How did the fires that started in similar weather in this area end?
Fires less than 250 km away that started since 2016 with a similar FWI, humidity and dry spell: 55. Their median duration was 10 days and their median area 2,506 ha; 100 % went past 1,000 ha. In 53 of 55, not even 1 mm fell in the ten days after the end: they went out without rain. In the rest, the first rainy day brought a median of 1.7 mm.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Emergency number: 112 · Emergency number and official warnings

Satellite cross-check

History of this page · 2 Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.
  1. Last day with fire: 14 January 2020 → 19 January 2020.
  2. Start date: 11 January 2020 → 8 January 2020.

RSS Changes to this page With cross-checks and a citable version

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy. This is not an emergency service: if there is a fire now, call 112.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates adjusted with the VIIRS detections inside the perimeter, which said 11 January 2020 to 14 January 2020. 70 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2020, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 4.0 International (CC BY 4.0)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.