Skip to content
worldfires
ID · Indonesia · →

Sanggau fire, 1 August 2026 Sanggau

Out · last detection 10 Aug 2026, 06:18 UTC

The fire started on 1 August 2026 in Sanggau, Indonesia, and satellites saw it burning for 11 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 2,249 hectares from heat detections, spread across a single municipality.

It is the 135th largest in West Kalimantan since 2016 (of 267 with a page). Number 575 in Indonesia in 2026, of 1004.

Compare with…
Burnt area
2,249ha
GWIS perimeter (Copernicus)
Duration
11days
1 Aug 2026 – 11 Aug 2026
Municipalities hit
1
regencies
Started on
1 Aug
2026
Heat detections
39
in a single hotspot: 50 MW
Danger at start
2
Very low · FWI index
Average daily power
59MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 1 Aug11 Aug
10 Aug 2026

How it evolved, day by day

1 Aug 2026 · 5 MW · 1 2 Aug 2026 · 99 MW · 6 5 Aug 2026 · 5 MW · 1 6 Aug 2026 · 160 MW · 16 7 Aug 2026 · 134 MW · 13 8 Aug 2026 · 5 MW · 1 10 Aug 2026 · 3 MW · 1
1 Aug 2 Aug 5 Aug 6 Aug 7 Aug 8 Aug 10 Aug

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

36°high
24km/h · peak gust
30%lowest humidity

It had gone 0 days without rain (1 mm or more) when it started. Rain came after the fire: 4.4 mm on 23 Aug.

This area had burned before

29% of the perimeter overlaps earlier fires recorded since 2016: 252 ha in 2019, 45 ha in 2023, 516 ha in 2025. Part of it burned more than once, so the yearly figures add up to more than the 644 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 1.4% of the area of London (22 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Sanggau where it started
    2,264 ha
    0.2 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area3.4 ha
Residents≈ 700

Inside the perimeter there were about 3.4 hectares of built-up land and about 700 residents (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
1 Aug 33.0 °C 55 % 20 km/h 0.0 mm Very low 2
2 Aug 34.0 °C 49 % 17 km/h 0.0 mm Low 6
3 Aug 34.0 °C 49 % 23 km/h 0.8 mm Low 7
4 Aug 35.0 °C 44 % 19 km/h 0.1 mm Low 10
5 Aug 35.4 °C 31 % 19 km/h 0.0 mm Moderate 14
6 Aug 35.5 °C 37 % 16 km/h 0.0 mm Moderate 15
7 Aug 35.8 °C 38 % 22 km/h 0.0 mm Moderate 17
8 Aug 35.9 °C 30 % 22 km/h 0.0 mm Moderate 19
9 Aug 35.0 °C 37 % 12 km/h 0.0 mm Moderate 17
10 Aug 35.2 °C 38 % 12 km/h 0.0 mm Moderate 18
11 Aug 35.5 °C 38 % 16 km/h 0.0 mm Moderate 20
12 Aug after 34.8 °C 43 % 17 km/h 0.0 mm Moderate 19
13 Aug after 34.1 °C 46 % 19 km/h 0.0 mm Moderate 18
14 Aug after 35.1 °C 44 % 17 km/h 0.0 mm Moderate 18
15 Aug after 32.1 °C 63 % 19 km/h 6.9 mm Very low 1
16 Aug after 34.2 °C 48 % 24 km/h 0.1 mm Low 8
17 Aug after 33.7 °C 54 % 19 km/h 7.8 mm Very low 1
18 Aug after 35.0 °C 44 % 20 km/h 0.0 mm Low 8
19 Aug after 34.9 °C 44 % 20 km/h 0.0 mm Moderate 11
20 Aug after 33.5 °C 54 % 16 km/h 0.1 mm Moderate 12
21 Aug after 34.9 °C 44 % 23 km/h 0.0 mm Moderate 14
22 Aug after 34.7 °C 47 % 17 km/h 0.2 mm Moderate 14
23 Aug after 33.0 °C 60 % 16 km/h 4.4 mm Very low 2

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 25 Jul 2026
After · 18 Aug 2026

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 11 August 2026 the air beside the fire reached 315 µg/m³ of PM2.5. That day averaged 220: 15 times the WHO daily guideline (15).

PM2.5 peak315 µg/m³
Days over the guideline21 days
PM10320 µg/m³
Optical depth2.62
3031123456789101112131415161718192021
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 39Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Indonesia ›

Frequently asked questions

How long did the Sanggau fire last?
GWIS (Copernicus) dates it between 1 August 2026 and 11 August 2026: 11 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 2,249 hectares (22.5 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Sanggau (2,264 ha, 0.2 %).
What was the weather like?
During the fire the temperature reached 35.9 °C, humidity dropped to 30 % and gusts hit 24 km/h. The fire danger index (FWI) reached 20, class Moderate.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Indonesia (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Emergency number: 112 · Emergency number and official warnings ›

Satellite cross-check

History of this page Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.

No changes since 24 October 2026.

RSS Changes to this page

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy. This is not an emergency service: if there is a fire now, call 112.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates from the perimeter: the VIIRS detections inside it did not change them. 39 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology ›

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.