Skip to content
worldfires
KH · Cambodia · →

Rovieng fire, 5 February 2026 Rovieng

Out · last detection 25 Feb 2026, 06:28 UTC

The fire started on 5 February 2026 in Rovieng, Cambodia, and satellites saw it burning for 20 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 2,685 hectares from heat detections, spread across a single municipality.

It is the 49th largest in Preah Vihear since 2016 (of 97 with a page). Number 68 in Cambodia in 2026, of 120.

Compare with…
Burnt area
2,685ha
GWIS perimeter (Copernicus)
Duration
20days
5 Feb 2026 – 24 Feb 2026
Municipalities hit
1
districts
Started on
5 Feb
2026
Heat detections
245
in a single hotspot: 311 MW
Danger at start
25
High · FWI index
Average daily power
176MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 5 Feb24 Feb
25 Feb 2026

How it evolved, day by day

5 Feb 2026 · 443 MW · 41 6 Feb 2026 · 107 MW · 25 7 Feb 2026 · 31 MW · 9 8 Feb 2026 · 18 MW · 12 9 Feb 2026 · 1,562 MW · 39 10 Feb 2026 · 508 MW · 35 11 Feb 2026 · 152 MW · 16 12 Feb 2026 · 234 MW · 11 13 Feb 2026 · 103 MW · 9 14 Feb 2026 · 94 MW · 8 15 Feb 2026 · 167 MW · 15 16 Feb 2026 · 10 MW · 4 17 Feb 2026 · 1 MW · 1 18 Feb 2026 · 4 MW · 1 19 Feb 2026 · 1 MW · 2 20 Feb 2026 · 68 MW · 3 21 Feb 2026 · 1 MW · 2 22 Feb 2026 · 12 MW · 2 23 Feb 2026 · 0 MW · 1 25 Feb 2026 · 4 MW · 1
5 Feb 8 Feb 9 Feb 11 Feb 14 Feb 17 Feb 20 Feb 23 Feb

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

37°high
41km/h · peak gust
28%lowest humidity

It had gone more than two months without rain (1 mm or more) when it started. Rain came after the fire: 16.6 mm on 27 Feb.

This area had burned before

59% of the perimeter overlaps earlier fires recorded since 2016: 29 ha in 2018, 2 ha in 2019, 230 ha in 2020, 498 ha in 2021, 804 ha in 2023, 1,010 ha in 2024. Part of it burned more than once, so the yearly figures add up to more than the 1,571 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 1.7% of the area of London (27 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Rovieng where it started
    2,700 ha
    1.2 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area< 0.1 ha
Residents< 20

Inside the perimeter there was no noticeable built-up land and almost nobody lived there (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
5 Feb 34.8 °C 39 % 22 km/h 0.0 mm High 25
6 Feb 34.6 °C 41 % 19 km/h 0.0 mm High 26
7 Feb 32.1 °C 57 % 23 km/h 0.6 mm Moderate 20
8 Feb 32.0 °C 46 % 34 km/h 0.0 mm High 22
9 Feb 34.1 °C 34 % 40 km/h 0.0 mm High 30
10 Feb 34.4 °C 35 % 32 km/h 0.0 mm High 28
11 Feb 33.6 °C 46 % 30 km/h 0.0 mm High 26
12 Feb 35.5 °C 38 % 26 km/h 0.0 mm High 26
13 Feb 35.8 °C 35 % 27 km/h 0.0 mm High 28
14 Feb 35.8 °C 31 % 26 km/h 0.0 mm High 30
15 Feb 36.7 °C 28 % 32 km/h 0.0 mm High 33
16 Feb 36.5 °C 33 % 23 km/h 0.0 mm High 33
17 Feb 36.0 °C 32 % 31 km/h 0.0 mm High 35
18 Feb 36.0 °C 33 % 41 km/h 0.0 mm High 37
19 Feb 35.7 °C 32 % 37 km/h 0.0 mm High 36
20 Feb 35.9 °C 32 % 35 km/h 0.0 mm High 36
21 Feb 35.8 °C 33 % 24 km/h 0.0 mm High 33
22 Feb 36.1 °C 39 % 18 km/h 0.0 mm High 31
23 Feb 33.7 °C 54 % 27 km/h 0.4 mm High 24
24 Feb 36.0 °C 42 % 24 km/h 0.0 mm High 25
25 Feb after 34.7 °C 46 % 24 km/h 0.0 mm High 24
26 Feb after 33.7 °C 52 % 22 km/h 0.0 mm High 25
27 Feb after 27.7 °C 82 % 20 km/h 16.6 mm Very low 0

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 29 Jan 2026
After · 3 Mar 2026

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 10 February 2026 the air beside the fire reached 96 µg/m³ of PM2.5. That day averaged 46: 3.1 times the WHO daily guideline (15).

PM2.5 peak96 µg/m³
Days over the guideline21 days
PM1097 µg/m³
Optical depth1.37
3456789101112131415161718192021222324252627
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 245Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Cambodia ›

Frequently asked questions

How long did the Rovieng fire last?
GWIS (Copernicus) dates it between 5 February 2026 and 24 February 2026: 20 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 2,685 hectares (26.8 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Rovieng (2,700 ha, 1.2 %).
What was the weather like?
During the fire the temperature reached 36.7 °C, humidity dropped to 28 % and gusts hit 41 km/h. The fire danger index (FWI) reached 37, class High.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Cambodia (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

History of this page Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.

No changes since 24 October 2026.

RSS Changes to this page

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates from the perimeter: the VIIRS detections inside it did not change them. 245 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology ›

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 4.0 International (CC BY 4.0)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.