Ouandja fire, 16 November 2025 Ouandja

Out · last detection 23 Nov 2025, 12:32 UTC

The fire started on 16 November 2025 in Ouandja, Central African Republic, and satellites saw it burning for 9 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 5,671 hectares from heat detections, spread across a single municipality.

It is the 64th largest in Vakaga since 2016 (of 83 with a page). Number 115 in Central African Republic in 2025, of 138.

The power measured by the satellite is low (25.5 MW in the strongest hotspot), more typical of grass or stubble burning, or a slow surface fire, than of a large crown fire.

Compare with…
Burnt area
5,671ha
GWIS perimeter (Copernicus)
Duration
9days
16 Nov 2025 – 24 Nov 2025
Municipalities hit
1
sub-prefectures
Started on
16 Nov
2025
Heat detections
85
in a single hotspot: 25 MW
Danger at start
52
Extreme · FWI index
Average daily power
116MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 16 Nov24 Nov
23 Nov 2025

How it evolved, day by day

16 Nov 2025 · 1 MW · 1 17 Nov 2025 · 53 MW · 8 18 Nov 2025 · 310 MW · 39 19 Nov 2025 · 352 MW · 26 20 Nov 2025 · 93 MW · 9 22 Nov 2025 · 1 MW · 1 23 Nov 2025 · 5 MW · 1
16 Nov 17 Nov 18 Nov 19 Nov 20 Nov 22 Nov 23 Nov

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

37°high
42km/h · peak gust
11%lowest humidity

It had gone 21 days without rain (1 mm or more) when it started.

This area had burned before

52% of the perimeter overlaps earlier fires recorded since 2016: 1,423 ha in 2016, 555 ha in 2017, 828 ha in 2021, 344 ha in 2022, 834 ha in 2024. Part of it burned more than once, so the yearly figures add up to more than the 2,944 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 3.6% of the area of London (57 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Ouandja where it started
    5,704 ha reached on 16 Nov
    0.3 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area< 0.1 ha
Residents< 20

Inside the perimeter there was no noticeable built-up land and almost nobody lived there (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
16 Nov 34.0 °C 15 % 40 km/h 0.0 mm Extreme 52
17 Nov 34.3 °C 14 % 42 km/h 0.0 mm Extreme 53
18 Nov 35.4 °C 16 % 38 km/h 0.0 mm Extreme 51
19 Nov 36.2 °C 17 % 38 km/h 0.0 mm Extreme 52
20 Nov 36.0 °C 14 % 40 km/h 0.0 mm Extreme 53
21 Nov 35.9 °C 11 % 37 km/h 0.0 mm Extreme 51
22 Nov 36.5 °C 11 % 31 km/h 0.0 mm Very high 47
23 Nov 36.8 °C 14 % 35 km/h 0.0 mm Extreme 51
24 Nov 36.8 °C 20 % 26 km/h 0.0 mm Very high 44
25 Nov after 36.5 °C 19 % 40 km/h 0.0 mm Extreme 53
26 Nov after 35.9 °C 16 % 45 km/h 0.0 mm Extreme 57
27 Nov after 35.9 °C 14 % 40 km/h 0.0 mm Extreme 54
28 Nov after 35.0 °C 14 % 39 km/h 0.0 mm Extreme 54
29 Nov after 36.1 °C 15 % 43 km/h 0.0 mm Extreme 57
30 Nov after 36.2 °C 19 % 48 km/h 0.0 mm Extreme 62
1 Dec after 36.0 °C 19 % 48 km/h 0.0 mm Extreme 60
2 Dec after 35.6 °C 17 % 45 km/h 0.0 mm Extreme 59
3 Dec after 34.7 °C 17 % 41 km/h 0.0 mm Extreme 56
4 Dec after 36.4 °C 16 % 41 km/h 0.0 mm Extreme 56

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 9 Nov 2025
After · 1 Dec 2025

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 14 November 2025 the air beside the fire reached 44 µg/m³ of PM2.5. That day averaged 28: 1.9 times the WHO daily guideline (15).

PM2.5 peak44 µg/m³
Days over the guideline13 days
PM10250 µg/m³
Optical depth0.42
1415161718192021222324252627
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 85Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Central African Republic ›

Frequently asked questions

How long did the Ouandja fire last?
According to the heat detections seen by satellite inside the perimeter, it burned from 16 November 2025 to 24 November 2025 (9 days). The perimeter dates it from 17 November 2025 to 20 November 2025.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 5,671 hectares (56.7 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Ouandja (5,704 ha, 0.3 %).
What was the weather like?
During the fire the temperature reached 36.8 °C, humidity dropped to 11 % and gusts hit 42 km/h. The fire danger index (FWI) reached 53, class Extreme.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Central African Republic (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

History of this page Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.

No changes since 24 October 2026.

RSS Changes to this page

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates adjusted with the VIIRS detections inside the perimeter, which said 17 November 2025 to 20 November 2025. 85 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology ›

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM3 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.