Skip to content
worldfires
MW · Malawi · →

Nsanje fire, September 2026 Nsanje

Out · last detection 17 Sept 2026, 11:06 UTC

The fire started on 12 September 2026 in Nsanje, Malawi, and satellites saw it burning for 8 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 1,219 hectares from heat detections, spread across a single municipality.

It is the 66th largest in Southern Region since 2016 (of 106 with a page). Number 79 in Malawi in 2026, of 109.

The power measured by the satellite is low (6.0 MW in the strongest hotspot), more typical of grass or stubble burning, or a slow surface fire, than of a large crown fire.

Compare with…

Suggestions: Nsanje · 2020

Burnt area
1,219ha
GWIS perimeter (Copernicus)
Duration
8days
12 Sept 2026 – 19 Sept 2026
Municipalities hit
1
districts
Started on
12 Sept
2026
Heat detections
15
in a single hotspot: 6 MW
Danger at start
34
High · FWI index
Average daily power
9MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 12 Sept19 Sept
17 Sept 2026

How it evolved, day by day

12 Sept 2026 · 9 MW · 2 13 Sept 2026 · 15 MW · 4 14 Sept 2026 · 2 MW · 1 15 Sept 2026 · 10 MW · 3 16 Sept 2026 · 18 MW · 4 17 Sept 2026 · 2 MW · 1
12 Sept 13 Sept 14 Sept 15 Sept 16 Sept 17 Sept

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

35°high
49km/h · peak gust
16%lowest humidity

It had gone one day without rain (1 mm or more) when it started. Rain came after the fire: 2.5 mm on 29 Sept.

This area had burned before

50% of the perimeter overlaps earlier fires recorded since 2016: 371 ha in 2016, 546 ha in 2022. Part of it burned more than once, so the yearly figures add up to more than the 605 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 0.8% of the area of London (12 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Nsanje where it started
    509 ha reached on 13 Sept
    0.3 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area0.90 ha
Residents≈ 200

Inside the perimeter there were about 0.90 hectares of built-up land and about 200 residents (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
12 Sept 31.3 °C 32 % 40 km/h 0.0 mm High 34
13 Sept 31.2 °C 30 % 32 km/h 0.0 mm High 34
14 Sept 31.1 °C 27 % 36 km/h 0.0 mm High 38
15 Sept 33.3 °C 22 % 38 km/h 0.0 mm Very high 43
16 Sept 34.4 °C 16 % 42 km/h 0.0 mm Very high 49
17 Sept 34.9 °C 17 % 37 km/h 0.0 mm Very high 48
18 Sept 33.6 °C 20 % 49 km/h 0.0 mm Extreme 58
19 Sept 30.9 °C 24 % 45 km/h 0.0 mm Extreme 51
20 Sept after 30.4 °C 30 % 42 km/h 0.0 mm Very high 45
21 Sept after 29.5 °C 38 % 37 km/h 0.0 mm High 37
22 Sept after 30.1 °C 34 % 37 km/h 0.0 mm High 37
23 Sept after 29.7 °C 35 % 36 km/h 0.1 mm High 35
24 Sept after 30.4 °C 32 % 42 km/h 0.0 mm Very high 40
25 Sept after 28.8 °C 34 % 37 km/h 0.3 mm Very high 38
26 Sept after 31.6 °C 32 % 27 km/h 0.0 mm High 34
27 Sept after 35.1 °C 24 % 27 km/h 0.0 mm Very high 38
28 Sept after 37.5 °C 24 % 40 km/h 0.1 mm Very high 48
29 Sept after 32.8 °C 34 % 54 km/h 2.5 mm High 29

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 5 Sept 2026
After · 26 Sept 2026

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 17 September 2026 the air beside the fire reached 113 µg/m³ of PM2.5. That day averaged 58: 3.9 times the WHO daily guideline (15).

PM2.5 peak113 µg/m³
Days over the guideline8 days
PM10118 µg/m³
Optical depth2.16
10111213141516171819202122
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 15Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Malawi ›

Frequently asked questions

How long did the Nsanje fire last?
According to the heat detections seen by satellite inside the perimeter, it burned from 12 September 2026 to 19 September 2026 (8 days). The perimeter dates it from 12 September 2026 to 17 September 2026.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 1,219 hectares (12.2 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Nsanje (509 ha, 0.3 %).
What was the weather like?
During the fire the temperature reached 34.9 °C, humidity dropped to 16 % and gusts hit 49 km/h. The fire danger index (FWI) reached 58, class Extreme.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Malawi (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

History of this page Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.

No changes since 24 October 2026.

RSS Changes to this page

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates adjusted with the VIIRS detections inside the perimeter, which said 12 September 2026 to 17 September 2026. 15 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology ›

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.