Skip to content
worldfires
CG · Republic of the Congo · –

Nkayi fire, 1 August 2026 Nkayi

Out · last detection 5 Aug 2026, 12:55 UTC

The fire started on 1 August 2026 in Nkayi, Republic of the Congo, and satellites saw it burning for 5 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 1,305 hectares from heat detections, spread across a single municipality.

It is the 93th largest in Bouenza since 2016 (of 181 with a page). Number 184 in Republic of the Congo in 2026, of 360.

Compare with…

Suggestions: Nkayi · 2026Madingou · 2026

Burnt area
1,305ha
GWIS perimeter (Copernicus)
Duration
5days
1 Aug 2026 – 5 Aug 2026
Municipalities hit
1
districts
Started on
1 Aug
2026
Heat detections
4
in a single hotspot: 123 MW
Danger at start
18
Moderate · FWI index
Average daily power
102MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 1 Aug5 Aug
5 Aug 2026

How it evolved, day by day

3 Aug 2026 · 56 MW · 9 4 Aug 2026 · 59 MW · 5 5 Aug 2026 · 192 MW · 4
3 Aug 4 Aug 5 Aug

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

33°high
29km/h · peak gust
46%lowest humidity

It had gone more than two months without rain (1 mm or more) when it started.

This area had burned before

No earlier perimeters overlap this fire since 2016, when the satellite record begins.

How big is it?

10 km
It burned the equivalent of 0.8% of the area of London (13 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Nkayi where it started
    1,314 ha reached on 5 Aug
    1.1 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
1 Aug 28.7 °C 61 % 29 km/h 0.0 mm Moderate 18
2 Aug 25.5 °C 68 % 21 km/h 0.0 mm Moderate 16
3 Aug 30.0 °C 56 % 18 km/h 0.0 mm Moderate 17
4 Aug 32.7 °C 46 % 21 km/h 0.0 mm High 22
5 Aug 29.5 °C 61 % 22 km/h 0.0 mm Moderate 20
6 Aug after 27.5 °C 61 % 21 km/h 0.0 mm Moderate 18
7 Aug after 26.5 °C 67 % 23 km/h 0.0 mm Moderate 17
8 Aug after 25.6 °C 70 % 23 km/h 0.0 mm Moderate 15
9 Aug after 25.0 °C 73 % 22 km/h 0.2 mm Moderate 13
10 Aug after 25.9 °C 68 % 24 km/h 0.0 mm Moderate 13
11 Aug after 26.4 °C 64 % 25 km/h 0.0 mm Moderate 14
12 Aug after 29.0 °C 55 % 30 km/h 0.0 mm Moderate 18
13 Aug after 26.0 °C 70 % 19 km/h 0.0 mm Moderate 14
14 Aug after 25.9 °C 69 % 21 km/h 0.1 mm Moderate 15
15 Aug after 26.5 °C 68 % 19 km/h 0.1 mm Moderate 15

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 25 Jul 2026
After · 12 Aug 2026

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 2 August 2026 the air beside the fire reached 89 µg/m³ of PM2.5. That day averaged 49: 3.2 times the WHO daily guideline (15).

PM2.5 peak89 µg/m³
Days over the guideline10 days
PM1093 µg/m³
Optical depth1.71
30 Jul1 Aug3 Aug5 Aug7 Aug
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 4Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Republic of the Congo

Frequently asked questions

How long did the Nkayi fire last?
GWIS (Copernicus) dates it between 1 August 2026 and 5 August 2026: 5 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 1,305 hectares (13.0 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Nkayi (1,314 ha, 1.1 %).
What was the weather like?
During the fire the temperature reached 32.7 °C, humidity dropped to 46 % and gusts hit 29 km/h. The fire danger index (FWI) reached 22, class High.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Republic of the Congo (geoBoundaries ADM2). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

History of this page Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.

No changes since 24 October 2026.

RSS Changes to this page

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates from the perimeter: the VIIRS detections inside it did not change them. 4 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.

How we build fire pages: methodology

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Map Library 2007, nombres de Wikidata) (Public Domain). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.