Skip to content
worldfires
SN · Senegal · →

Nianing fire, January 2025 Nianing

Out · last detection 4 Feb 2025, 13:47 UTC

The fire started on 31 January 2025 in Nianing, Senegal, and satellites saw it burning for 5 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 2,593 hectares from heat detections, spread across a single municipality.

It is the 104th largest in Kolda since 2016 (of 195 with a page). Number 70 in Senegal in 2025, of 112.

Burnt area
2,593ha
GWIS perimeter (Copernicus)
Duration
5days
31 Jan 2025 – 4 Feb 2025
Municipalities hit
1
districts
Started on
31 Jan
2025
Heat detections
80
in a single hotspot: 32 MW
Energy released
505MW
sum of detected power

Where it burned

4 Feb 2025
HOTSPOTS BY DAY 31 Jan4 Feb

How it evolved, day by day

311234

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

This area had burned before

67% of the perimeter overlaps earlier fires recorded since 2016: 740 ha in 2016, 79 ha in 2017, 1,368 ha in 2020, 1,124 ha in 2023. Part of it burned more than once, so the yearly figures add up to more than the 1,747 ha that had burned before.

What happened to each town

  1. Nianing where it started
    2,609 ha reached on 31 Jan
    1.6 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance is from the town centre to the nearest fire: staying a kilometre away does not mean it reached the houses.

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 24 Jan 2025
After · 11 Feb 2025

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 7 February 2025 the air beside the fire reached 104 µg/m³ of PM2.5. That day averaged 88: 5.9 times the WHO daily guideline (15).

PM2.5 peak104 µg/m³
Days over the guideline10 days
PM10431 µg/m³
Optical depth0.66
2930311234567
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 80Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Senegal ›

Frequently asked questions

How long did the Nianing fire last?
GWIS (Copernicus) dates it between 31 January 2025 and 4 February 2025: 5 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 2,593 hectares (25.9 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Nianing (2,609 ha, 1.6 %).
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Senegal (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Emergency number: 18

Satellite cross-check

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy. This is not an emergency service: if there is a fire now, call 18.

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM3 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.