Skip to content
worldfires
CG · Congo - Brazzaville · →

Mvouti fire, 23 July 2016 Mvouti

Out · last detection 9 Aug 2016, 12:44 UTC

The fire started on 23 July 2016 in Mvouti, Congo - Brazzaville, and satellites saw it burning for 18 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 10,996 hectares from heat detections, spread across a single municipality.

It is the 2th largest in Pool since 2016 (of 333 with a page). The largest in Congo - Brazzaville in 2016, of 98.

The power measured by the satellite is low (26.8 MW in the strongest hotspot), more typical of grass or stubble burning, or a slow surface fire, than of a large crown fire.

Burnt area
10,996ha
GWIS perimeter (Copernicus)
Duration
18days
23 Jul 2016 – 9 Aug 2016
Municipalities hit
1
districts
Started on
23 Jul
2016
Heat detections
351
in a single hotspot: 27 MW
Danger at start
16
Moderate · FWI index
Energy released
1.4GW
sum of detected power

Where it burned

9 Aug 2016
HOTSPOTS BY DAY 23 Jul9 Aug

How it evolved, day by day

2425262728293031123456789

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

32°high
40km/h · peak gust
43%lowest humidity

It had gone 22 days without rain (1 mm or more) when it started. Rain came after the fire: 1.4 mm on 10 Aug.

This area had burned before

No earlier perimeters overlap this fire since 2016, when the satellite record begins.

What happened to each town

  1. Mvouti where it started
    11,066 ha reached on 24 Jul
    1.5 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance is from the town centre to the nearest fire: staying a kilometre away does not mean it reached the houses.

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
23 Jul 29.0 °C 55 % 27 km/h 0.0 mm Moderate 16
24 Jul 28.0 °C 55 % 30 km/h 0.0 mm Moderate 16
25 Jul 26.6 °C 54 % 29 km/h 0.0 mm Moderate 17
26 Jul 28.2 °C 49 % 28 km/h 0.0 mm Moderate 18
27 Jul 29.9 °C 48 % 28 km/h 0.0 mm Moderate 19
28 Jul 29.6 °C 51 % 28 km/h 0.0 mm Moderate 20
29 Jul 29.6 °C 50 % 30 km/h 0.0 mm Moderate 21
30 Jul 29.2 °C 53 % 32 km/h 0.0 mm Moderate 20
31 Jul 29.9 °C 52 % 27 km/h 0.0 mm Moderate 21
1 Aug 32.1 °C 43 % 32 km/h 0.0 mm High 24
2 Aug 27.2 °C 58 % 40 km/h 0.0 mm High 23
3 Aug 29.5 °C 50 % 35 km/h 0.0 mm High 22
4 Aug 30.6 °C 49 % 33 km/h 0.0 mm High 23
5 Aug 29.1 °C 52 % 34 km/h 0.0 mm High 22
6 Aug 28.7 °C 54 % 35 km/h 0.0 mm High 22
7 Aug 28.3 °C 54 % 37 km/h 0.0 mm High 24
8 Aug 29.1 °C 52 % 26 km/h 0.1 mm Moderate 20
9 Aug 31.7 °C 50 % 29 km/h 0.0 mm Moderate 18
10 Aug after 28.5 °C 59 % 27 km/h 1.4 mm Low 10

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 16 Jul 2016
After · 16 Aug 2016

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

Detections table · 351Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Congo - Brazzaville ›

Frequently asked questions

How long did the Mvouti fire last?
GWIS (Copernicus) dates it between 23 July 2016 and 9 August 2016: 18 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 10,996 hectares (110.0 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Mvouti (11,066 ha, 1.5 %).
What was the weather like?
During the fire the temperature reached 32.1 °C, humidity dropped to 43 % and gusts hit 40 km/h. The fire danger index (FWI) reached 24, class High.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Congo - Brazzaville (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Public Domain). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.