Skip to content
worldfires
AO · Angola · →

Mucaba fire, September 2026 Mucaba, Damba, Songo

Out · last detection 20 Sept 2026, 13:33 UTC

The fire started on 1 September 2026 in Mucaba, Angola, and satellites saw it burning for 19 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 16,449 hectares from heat detections, spread across 3 municipalities.

It is the 18th largest in Uíge since 2016 (of 59 with a page). Number 77 in Angola in 2026, of 486.

Burnt area
16,449ha
GWIS perimeter (Copernicus)
Duration
19days
1 Sept 2026 – 19 Sept 2026
Municipalities hit
3
municipalities
Started on
1 Sept
2026
Heat detections
490
in a single hotspot: 389 MW
Danger at start
4
Very low · FWI index
Energy released
4.8GW
sum of detected power

Where it burned

20 Sept 2026
HOTSPOTS BY DAY 1 Sept19 Sept

How it evolved, day by day

12457891011121314151617181920

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

30°high
31km/h · peak gust
46%lowest humidity

It had gone 4 days without rain (1 mm or more) when it started. Rain came after the fire: 11.7 mm on 25 Sept.

This area had burned before

85% of the perimeter overlaps earlier fires recorded since 2016: 4,337 ha in 2016, 1,891 ha in 2017, 904 ha in 2019, 4,462 ha in 2021, 6,603 ha in 2022, 1,111 ha in 2023, 3,947 ha in 2024, 12,876 ha in 2025. Part of it burned more than once, so the yearly figures add up to more than the 13,902 ha that had burned before.

What happened to each town

  1. Mucaba where it started
    8,299 ha reached on 1 Sept
    7.8 %
  2. 6,337 ha reached on 1 Sept
    0.9 %
  3. 1,920 ha reached on 2 Sept
    0.7 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance is from the town centre to the nearest fire: staying a kilometre away does not mean it reached the houses.

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
1 Sept 27.6 °C 55 % 26 km/h 3.6 mm Very low 4
2 Sept 27.2 °C 56 % 28 km/h 2.4 mm Very low 4
3 Sept 22.0 °C 71 % 31 km/h 0.4 mm Very low 5
4 Sept 26.7 °C 57 % 31 km/h 0.4 mm Low 10
5 Sept 25.9 °C 57 % 30 km/h 0.6 mm Low 11
6 Sept 25.1 °C 59 % 27 km/h 3.3 mm Very low 3
7 Sept 28.3 °C 53 % 26 km/h 5.9 mm Very low 1
8 Sept 28.0 °C 55 % 26 km/h 6.9 mm Very low 1
9 Sept 23.4 °C 69 % 28 km/h 0.9 mm Very low 1
10 Sept 22.4 °C 71 % 26 km/h 2.3 mm Very low 1
11 Sept 22.4 °C 70 % 31 km/h 0.4 mm Very low 2
12 Sept 26.2 °C 59 % 23 km/h 2.7 mm Very low 1
13 Sept 23.4 °C 63 % 27 km/h 0.2 mm Very low 2
14 Sept 29.6 °C 49 % 23 km/h 1.7 mm Very low 3
15 Sept 25.9 °C 61 % 27 km/h 2.7 mm Very low 1
16 Sept 24.0 °C 64 % 29 km/h 0.6 mm Very low 3
17 Sept 24.1 °C 63 % 24 km/h 0.0 mm Very low 4
18 Sept 22.2 °C 69 % 25 km/h 0.0 mm Very low 4
19 Sept 24.8 °C 60 % 27 km/h 0.4 mm Low 6
20 Sept after 26.2 °C 56 % 31 km/h 1.7 mm Very low 3
21 Sept after 23.5 °C 67 % 29 km/h 2.3 mm Very low 1
22 Sept after 26.1 °C 54 % 26 km/h 0.1 mm Very low 3
23 Sept after 29.7 °C 46 % 28 km/h 1.3 mm Very low 4
24 Sept after 27.0 °C 57 % 28 km/h 14.2 mm Very low 0
25 Sept after 27.2 °C 56 % 24 km/h 11.7 mm Very low 0

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 25 Aug 2026
After · 26 Sept 2026

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 9 September 2026 the air beside the fire reached 119 µg/m³ of PM2.5. That day averaged 76: 5.1 times the WHO daily guideline (15).

PM2.5 peak119 µg/m³
Days over the guideline28 days
PM10123 µg/m³
Optical depth2.36
3031123456789101112131415161718192021222324252627
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 490Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Angola ›

Frequently asked questions

How long did the Mucaba fire last?
GWIS (Copernicus) dates it between 1 September 2026 and 19 September 2026: 19 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 16,449 hectares (164.5 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire entered 3 municipalities: Mucaba (8,299 ha, 7.8 %); Damba (6,337 ha, 0.9 %); Songo (1,920 ha, 0.7 %).
What was the weather like?
During the fire the temperature reached 29.7 °C, humidity dropped to 46 % and gusts hit 31 km/h. The fire danger index (FWI) reached 11, class Low.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Angola (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Public Domain). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.