Skip to content
worldfires
GN · Guinea · →

Moribayah fire, 28 January 2026 Moribayah, Mamouroudou

Out · last detection 3 Feb 2026, 02:20 UTC

The fire started on 28 January 2026 in Moribayah, Guinea, and satellites saw it burning for 7 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 2,520 hectares from heat detections, spread across 2 municipalities.

It is the 229th largest in Kankan since 2016 (of 388 with a page). Number 165 in Guinea in 2026, of 268.

The power measured by the satellite is low (24.6 MW in the strongest hotspot), more typical of grass or stubble burning, or a slow surface fire, than of a large crown fire.

Compare with…
Burnt area
2,520ha
GWIS perimeter (Copernicus)
Duration
7days
28 Jan 2026 – 3 Feb 2026
Municipalities hit
2
sub-prefectures
Started on
28 Jan
2026
Heat detections
41
in a single hotspot: 25 MW
Danger at start
33
High · FWI index
Average daily power
56MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 28 Jan3 Feb
3 Feb 2026

How it evolved, day by day

28 Jan 2026 · 114 MW · 9 29 Jan 2026 · 101 MW · 10 30 Jan 2026 · 137 MW · 12 31 Jan 2026 · 26 MW · 5 1 Feb 2026 · 1 MW · 1 2 Feb 2026 · 7 MW · 1 3 Feb 2026 · 3 MW · 3
28 Jan 29 Jan 30 Jan 31 Jan 1 Feb 2 Feb 3 Feb

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

36°high
26km/h · peak gust
13%lowest humidity

It had gone 21 days without rain (1 mm or more) when it started.

This area had burned before

100% of the perimeter overlaps earlier fires recorded since 2016: 1,605 ha in 2016, 1,578 ha in 2017, 1,945 ha in 2019, 2,060 ha in 2020, 1,002 ha in 2021, 1,479 ha in 2022, 824 ha in 2023, 1,562 ha in 2024, 438 ha in 2025. Part of it burned more than once, so the yearly figures add up to more than the 2,536 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 1.6% of the area of London (25 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Moribayah where it started
    2,354 ha reached on 28 Jan
    1.4 %
  2. 180 ha reached on 2 Feb
    0.1 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area< 0.1 ha
Residents< 20

Inside the perimeter there was no noticeable built-up land and almost nobody lived there (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
28 Jan 34.4 °C 13 % 22 km/h 0.0 mm High 33
29 Jan 34.5 °C 14 % 21 km/h 0.0 mm High 34
30 Jan 35.1 °C 14 % 22 km/h 0.0 mm High 34
31 Jan 36.1 °C 13 % 19 km/h 0.0 mm High 35
1 Feb 35.2 °C 26 % 26 km/h 0.0 mm High 33
2 Feb 36.0 °C 18 % 24 km/h 0.0 mm High 33
3 Feb 32.5 °C 34 % 24 km/h 0.1 mm High 29
4 Feb after 30.8 °C 38 % 18 km/h 0.2 mm High 27
5 Feb after 34.8 °C 20 % 31 km/h 0.0 mm High 33
6 Feb after 35.8 °C 15 % 30 km/h 0.0 mm Very high 38
7 Feb after 36.4 °C 12 % 26 km/h 0.0 mm Very high 39
8 Feb after 36.3 °C 13 % 24 km/h 0.0 mm Very high 40
9 Feb after 35.7 °C 12 % 28 km/h 0.0 mm Very high 40
10 Feb after 36.1 °C 14 % 22 km/h 0.0 mm Very high 40
11 Feb after 35.9 °C 19 % 20 km/h 0.0 mm Very high 42

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 21 Jan 2026
After · 10 Feb 2026

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 28 January 2026 the air beside the fire reached 101 µg/m³ of PM2.5. That day averaged 73: 4.8 times the WHO daily guideline (15).

PM2.5 peak101 µg/m³
Days over the guideline10 days
PM10191 µg/m³
Optical depth0.73
2627282930311234
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 41Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Guinea ›

Frequently asked questions

How long did the Moribayah fire last?
According to the heat detections seen by satellite inside the perimeter, it burned from 28 January 2026 to 3 February 2026 (7 days). The perimeter dates it from 28 January 2026 to 1 February 2026.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 2,520 hectares (25.2 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire entered 2 municipalities: Moribayah (2,354 ha, 1.4 %); Mamouroudou (180 ha, 0.1 %).
What was the weather like?
During the fire the temperature reached 36.1 °C, humidity dropped to 13 % and gusts hit 26 km/h. The fire danger index (FWI) reached 35, class High.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Guinea (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

History of this page · 1 Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.
  1. Last day with fire: 1 February 2026 → 3 February 2026.

RSS Changes to this page

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates adjusted with the VIIRS detections inside the perimeter, which said 28 January 2026 to 1 February 2026. 41 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology ›

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM3 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.